Resource metadata

Field Value
Data last updated January 18, 2024
Metadata last updated January 30, 2024
Created January 17, 2024
Format CSV
License CC-BY-NC-SA-4.0
Ckan urlhttps://data.cbwaterhub.ca
Data collection infoThe Hobo MX2203 temperature logger was deployed along Boivin Creek at site BOI001 on August 12, 2022. Measurements of temperature were taken at 1 hour intervals.
Data processingThe Water Hub has completed a preliminary QA/QC protocol on this file, however the individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data typenon-lab
Datastore activeTrue
Datastore contains all records of source fileTrue
Datastore statuspending
Has viewsTrue
Hash49b2cb6aee2ceb2b51b3511588518caa
Header row1
Id2fb37787-378c-4675-8af5-f8e4f7942e99
Ignore hashTrue
Load statusTable was successfully loaded: 7898 rows
Mimetypetext/csv
On same domainTrue
Original urlhttps://data.cbwaterhub.ca/dataset/bc6ff234-3996-438d-abde-ec03941ea621/resource/2fb37787-378c-4675-8af5-f8e4f7942e99/download/era_temp_boi001_20220812_20230707.csv
Package idbc6ff234-3996-438d-abde-ec03941ea621
Parameter[{'accuracy': '± 0.2°C', 'calibration': 'Factory calibrated', 'instrument_manufacturer': 'Onset', 'instrument_model': 'Hobo MX2203', 'instrument_type': 'Data Logger', 'notes_method': 'N/A', 'parameter': 'Water Temperature', 'parameter_unit': 'degrees celsius', 'range': '-20°C - 50°C (in water)', 'resolution': '0.01°C', 'serial_number': 21306944, 'time_zone': 'GMT-7'}]
Recent qa date2024-01-18
Resource citationElk River Watershed Alliance. (2023). Temperature (2022-08-12 to 2023-07-07) Boivin Creek (BOI001)[Resource]. Columbia Basin Water Hub. 10.48511/19h2-jt88
Resource data disclaimerNo warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Resource id2fb37787-378c-4675-8af5-f8e4f7942e99
Resource locationBoivin Creek, Elk River Watershed
Site[{'datum': 'NAD83', 'elevation': 1259, 'latitude': 50.02315, 'longitude': -114.91624, 'site_id': 'BOI001', 'site_name': 'Boivin Creek', 'waterbody': 'Boivin Creek', 'waterbody_type': 'stream/river'}]
Size577 KiB
Stateactive
Task created2024-01-18 21:21:59.746968
Url typeupload
Waterhub gradeTechnical Research Grade
upload
Citation (Required) Elk River Watershed Alliance. (2023). Temperature (2022-08-12 to 2023-07-07) Boivin Creek (BOI001)[Resource]. Columbia Basin Water Hub. 10.48511/19h2-jt88
Resource Location Boivin Creek, Elk River Watershed
Data Collection Information The Hobo MX2203 temperature logger was deployed along Boivin Creek at site BOI001 on August 12, 2022. Measurements of temperature were taken at 1 hour intervals.
Data Processing The Water Hub has completed a preliminary QA/QC protocol on this file, however the individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data Disclaimer No warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Water Hub Data Grade Technical Research Grade
Date of Most Recent Water Hub QA/QC 2024-01-18
Loading Status Table was successfully loaded: 7898 rows
Datastore Status pending
Data type General

Data Dictionary

Column Type Label Description BODC ID
date_time text
site_id text
latitude text
longitude text
notes text
water_temperature text
water_temperature_units text
water_hub_qa_qc text

Site

BOI001
Field Value
Site ID BOI001
Site Name Boivin Creek
Waterbody Type Stream/River
Waterbody Boivin Creek
Site Latitude 50.02315
Site Longitude -114.91624
Location Coordinate System NAD83
Site Elevation (masl) 1259

Parameter

Water Temperature
Field Value
Parameter Water Temperature
Time Zone GMT-7
Unit of Measurement degrees Celsius
Instrument Type Data Logger
Instrument Manufacturer Onset
Instrument Model Hobo MX2203
Serial Number 21306944
Instrument Accuracy ± 0.2°C
Range -20°C - 50°C (in water)
Resolution 0.01°C
Calibration Notes Factory calibrated
Notes on Method N/A