Skip to content

Changes

View changes from to


On August 15, 2022 at 10:01:18 PM UTC, Gravatar ameliasmart98:
  • Set format of resource LLC VOW 15 (2020-07-16 to 2020-11-06) to URL (previously XLSX) in LLC VOW 15 (WTN 90231)


  • Uploaded a new file to resource LLC VOW 15 (2020-07-16 to 2020-11-06) in LLC VOW 15 (WTN 90231)


  • Added field datastore_status to resource LLC VOW 15 (2020-07-16 to 2020-11-06) in LLC VOW 15 (WTN 90231)


  • Removed the value of field header_row in resource LLC VOW 15 (2020-07-16 to 2020-11-06) in LLC VOW 15 (WTN 90231)


  • Changed value of field data_collection_info of resource LLC VOW 15 (2020-07-16 to 2020-11-06) to Data is collected on five minute intervals, and reported on hourly intervals, with the effects of pumping removed. Continuous water level data were collected with a HOBO MX 2001 Bluetooth (9 meter range) water level logger. The data logger determines water levels by continuously collecting the absolute pressure of the water column above a sensor, compensating it for atmospheric pressure, and calibrating it with reference water levels that are collected manually. The atmospheric pressure is measured by a barometric sensor in the MX2001 top end unit that is installed in the airspace at the top of the wellhead. Manual water level level measurements were collected using either a Heron or Solinst water level tape (sounding tape). Water Level: Hobo MX2001 - 01 (Accuracy: Typical error: ±0.05% FS, 0.5 cm (0.015 ft) water. Maximum error: ±0.1% FS, 1.0 cm (0.03 ft) water) Water Temperature: Hobo MX2001 - 01 (Range: -20° to 50°C; Accuracy: ±0.44°C from 0° to 50°C) (previously Data is collected on five minute intervals, and reported on hourly intervals, with the effects of pumping removed. Continuous water level data were collected with a HOBO MX 2001 Bluetooth (9 meter range) water level logger. The data logger determines water levels by continuously collecting the absolute pressure of the water column above a sensor, compensating it for atmospheric pressure, and calibrating it with reference water levels that are collected manually. The atmospheric pressure is measured by a barometric sensor in the MX2001 top end unit that is installed in the airspace at the top of the wellhead. Manual water level level measurements were collected using either a Heron or Solinst water level tape (sounding tape).) in LLC VOW 15 (WTN 90231)


  • Removed the value of field url_type in resource LLC VOW 15 (2020-07-16 to 2020-11-06) in LLC VOW 15 (WTN 90231)