Resource metadata

Field Value
Data last updated December 6, 2023
Metadata last updated February 18, 2024
Created December 3, 2021
Format CSV
License CC-BY-SA-4.0
Data collection infoThe temperature loggers were deployed at the same locations for several years. They were installed fastened to a cable that was wrapped around a boulder or tree adjacent to the river.
Data processingParameters with unacceptably high or low readings were removed. These readings were likely due to the logger being swept out of the water during freshet or major weather events. The Water Hub has performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data typenon-lab
Datastore activeTrue
Datastore contains all records of source fileFalse
Datastore statusready
Has viewsTrue
Hashd3e35b91fd4e1e55f4b47b9cfd005384
Header row1
Idc1c79fea-c60b-4e96-8b2f-d722852a47f8
Load statusTable was successfully loaded: 80824 rows
Mimetypetext/csv
Package idfbe37553-853d-45e8-81c3-9d9e6eb091ba
Parameter[{'accuracy': '±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F)', 'calibration': 'Calibration is completed at each readout event. The logger is removed from metal housing tube and connected to HOBO Shuttle where the data is transfered. The shuttle is then offloaded onto the computer for analysis. The is completed roughly once every 2 years. During read out the loggers are checked for any damage to the logger/housing and battery status. Loggers with low battery life and/or damage are replaced.', 'instrument_manufacturer': 'HOBO', 'instrument_model': 'Pro V2', 'instrument_type': 'Data Logger', 'notes_method': 'Temperature Loggers are housed in a metal tube that is attached to a cable fastened to a tree or rock on shore. Cable lengths range from 2 to 4 meters. The logger/housing is placed in a deep pool and pinched between rocks to secure them during freshet.', 'parameter': 'Water Temperature', 'parameter_unit': 'degrees celsius', 'range': '-40° to 70°C (-40° to 158°F) in air; maximum sustained temperature of 50°C (122°F) in water', 'resolution': '0.02°C at 25°C (0.04°F at 77°F)', 'time_zone': 'PST'}]
Position0
Recent qa date2023-12-06
Resource citationSalmo Watershed Streamkeepers Society. (2021). Clearwater Creek Temperature (Upper - Lower) [Data set]. Columbia Basin Water Hub. https://doi.org/10.48511/6JEE-GA30
Resource data disclaimerNo warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Resource locationClearwater Creek Upper site was located ~10m upstream of bridge over Clearwater Creek (after Qua Creek bridge) on river right. Clearwater Creek Lower site was located at Camp busk road past NESLM03 site and across Apex Creek bridge, around corner and approx 300m from bridge. ~2m upstream of easy access point at stump on river right. ~20m upstream of log jam.
Site[{'datum': 'WGS84', 'elevation': 1280, 'latitude': 49.392452, 'longitude': -117.207755, 'site_id': 'clearwater_upper', 'site_name': 'clearwater_upper', 'waterbody': 'Samo River', 'waterbody_type': 'stream/river'}, {'datum': 'WGS84', 'elevation': 930, 'latitude': 49.159716, 'longitude': -117.092431, 'site_id': 'clearwater_lower', 'site_name': 'clearwater_lower', 'waterbody': 'Salmo River', 'waterbody_type': 'stream/river'}]
Size8 MiB
Stateactive
Url typeupload
Waterhub gradeCommunity Research Grade
Citation (Required) Salmo Watershed Streamkeepers Society. (2021). Clearwater Creek Temperature (Upper - Lower) [Data set]. Columbia Basin Water Hub. https://doi.org/10.48511/6JEE-GA30
Resource Location Clearwater Creek Upper site was located ~10m upstream of bridge over Clearwater Creek (after Qua Creek bridge) on river right. Clearwater Creek Lower site was located at Camp busk road past NESLM03 site and across Apex Creek bridge, around corner and approx 300m from bridge. ~2m upstream of easy access point at stump on river right. ~20m upstream of log jam.
Data Collection Information The temperature loggers were deployed at the same locations for several years. They were installed fastened to a cable that was wrapped around a boulder or tree adjacent to the river.
Data Processing Parameters with unacceptably high or low readings were removed. These readings were likely due to the logger being swept out of the water during freshet or major weather events. The Water Hub has performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data Disclaimer No warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Water Hub Data Grade Community Research Grade
Date of Most Recent Water Hub QA/QC 2023-12-06
Loading Status Table was successfully loaded: 80824 rows
Datastore Status ready
Data type General

Data Dictionary

Column Type Label Description BODC ID
date_time timestamp
site_id text
latitude float8
longitude float8
notes float8
water_temperature float8
water_temperature_units text
water_hub_qa_qc float8

Site

clearwater_upper
Field Value
Site ID clearwater_upper
Site Name clearwater_upper
Waterbody Type Stream/River
Waterbody Samo River
Site Latitude 49.392452
Site Longitude -117.207755
Location Coordinate System WGS84
Site Elevation (masl) 1280
clearwater_lower
Field Value
Site ID clearwater_lower
Site Name clearwater_lower
Waterbody Type Stream/River
Waterbody Salmo River
Site Latitude 49.159716
Site Longitude -117.092431
Location Coordinate System WGS84
Site Elevation (masl) 930

Parameter

Water Temperature
Field Value
Parameter Water Temperature
Time Zone PST
Unit of Measurement degrees Celsius
Instrument Type Data Logger
Instrument Manufacturer HOBO
Instrument Model Pro V2
Instrument Accuracy ±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F)
Range -40° to 70°C (-40° to 158°F) in air; maximum sustained temperature of 50°C (122°F) in water
Resolution 0.02°C at 25°C (0.04°F at 77°F)
Calibration Notes Calibration is completed at each readout event. The logger is removed from metal housing tube and connected to HOBO Shuttle where the data is transfered. The shuttle is then offloaded onto the computer for analysis. The is completed roughly once every 2 years. During read out the loggers are checked for any damage to the logger/housing and battery status. Loggers with low battery life and/or damage are replaced.
Notes on Method Temperature Loggers are housed in a metal tube that is attached to a cable fastened to a tree or rock on shore. Cable lengths range from 2 to 4 meters. The logger/housing is placed in a deep pool and pinched between rocks to secure them during freshet.