Resource metadata

Field Value
Data last updated March 3, 2024
Metadata last updated March 3, 2024
Created January 17, 2024
Format CSV
License CC-BY-NC-SA-4.0
Ckan urlhttps://data.cbwaterhub.ca
Data collection infoThe Hobo MX2203 temperature logger was deployed along the Elk River at site ELK002 on October 19, 2022. Measurements of temperature were taken at 1 hour intervals.
Data processingThe Water Hub has completed a preliminary QA/QC protocol on this file, however the individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data typenon-lab
Datastore activeTrue
Datastore contains all records of source fileTrue
Datastore statuspending
Has viewsTrue
Hashdf9cf45b87a535411f6ec9fccc9e4c57
Header row1
Id64ecdf72-91e6-4e0f-b7d8-8313a52057ae
Ignore hashTrue
Load statusTable was successfully loaded: 6411 rows
Mimetypetext/csv
Original urlhttps://data.cbwaterhub.ca/dataset/fcd82cb5-696b-436e-85bb-2948249498f8/resource/64ecdf72-91e6-4e0f-b7d8-8313a52057ae/download/era_temp_elk002_20221019_20230713.csv
Package idfcd82cb5-696b-436e-85bb-2948249498f8
Parameter[{'accuracy': '± 0.2°C', 'calibration': 'Factory calibrated', 'instrument_manufacturer': 'Onset', 'instrument_model': 'Hobo MX2203', 'instrument_type': 'Data Logger', 'notes_method': '', 'parameter': 'Water Temperature', 'parameter_unit': 'degrees celsius', 'range': '-20°C - 50°C (in water)', 'resolution': '0.01°C', 'serial_number': 21306956, 'time_zone': 'GMT-7'}]
Position2
Resource citationElk River Watershed Alliance. (2023). Temperature (2022-10-19 to 2023-07-13) Elk River (ELK002)[Resource]. Columbia Basin Water Hub. DOI
Resource data disclaimerNo warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Resource id64ecdf72-91e6-4e0f-b7d8-8313a52057ae
Resource locationElk River, Elk River Watershed
Set url typeFalse
Site[{'datum': 'NAD83', 'elevation': 1684, 'latitude': 50.5152762, 'longitude': -114.998874, 'site_id': 'ELK002', 'site_name': 'Elk River', 'waterbody': 'Elk River', 'waterbody_type': 'stream/river'}]
Size598.3 KiB
Stateactive
Task created2024-03-03 17:28:08.569423
Url typeupload
Waterhub gradeTechnical Research Grade
Citation (Required) Elk River Watershed Alliance. (2023). Temperature (2022-10-19 to 2023-07-13) Elk River (ELK002)[Resource]. Columbia Basin Water Hub. DOI
Resource Location Elk River, Elk River Watershed
Data Collection Information The Hobo MX2203 temperature logger was deployed along the Elk River at site ELK002 on October 19, 2022. Measurements of temperature were taken at 1 hour intervals.
Data Processing The Water Hub has completed a preliminary QA/QC protocol on this file, however the individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data Disclaimer No warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Water Hub Data Grade Technical Research Grade
Date of Most Recent Water Hub QA/QC
Loading Status Table was successfully loaded: 6411 rows
Datastore Status pending
Data type General

Data Dictionary

Column Type Label Description BODC ID
date_time timestamp
site_id text
latitude numeric
longitude numeric
notes text
water_temperature numeric
water_temperature_units text
water_hub_qa_qc text

Site

ELK002
Field Value
Site ID ELK002
Site Name Elk River
Waterbody Type Stream/River
Waterbody Elk River
Site Latitude 50.5152762
Site Longitude -114.998874
Location Coordinate System NAD83
Site Elevation (masl) 1684

Parameter

Water Temperature
Field Value
Parameter Water Temperature
Time Zone GMT-7
Unit of Measurement degrees Celsius
Instrument Type Data Logger
Instrument Manufacturer Onset
Instrument Model Hobo MX2203
Serial Number 21306956
Instrument Accuracy ± 0.2°C
Range -20°C - 50°C (in water)
Resolution 0.01°C
Calibration Notes Factory calibrated
Notes on Method