Resource metadata

Field Value
Data last updated December 14, 2023
Metadata last updated January 29, 2024
Created March 27, 2023
Format CSV
License CC-BY-SA-4.0
Data collection infoEKISC follows the British Columbia Dreissenid Mussel Lake Monitoring Field Protocol which is updated annually and provided by the Ministry of Environment. The protocol sets provincial standards for plankton tow sample collection, preservation, ancillary data collection, and shipment of samples.
Data processingThe Water Hub has performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data typenon-lab
Datastore activeTrue
Datastore contains all records of source fileFalse
Datastore statuspending
Has viewsTrue
Hash80067c5fbf110d0bd7369eaf092d58c6
Header row1
Idc0f8c23f-6d26-48d3-a521-2618df612e0b
Load statusTable was successfully loaded: 4 rows
Mimetypetext/csv
Package idb645229e-944c-49c4-801f-33ac56d545fb
Parameter[{'accuracy': '±0.5°C', 'calibration': 'Not specified', 'instrument_manufacturer': 'Hanna', 'instrument_model': 'HI98127', 'instrument_type': 'Other', 'instrument_type_other': 'pH Pen', 'notes_method': 'As per British Columbia Dreissenid Mussel Lake Monitoring Field Protocol', 'parameter': 'Water Temperature', 'parameter_unit': 'degrees celsius', 'range': '-5.0 to 60.0°C', 'resolution': '0.1°C', 'serial_number': 'Not specified', 'time_zone': 'MT'}, {'accuracy': '±0.1 pH', 'calibration': 'Not specified', 'instrument_manufacturer': 'Hanna', 'instrument_model': 'HI98127', 'instrument_type': 'Other', 'instrument_type_other': 'pH Pen', 'notes_method': 'As per British Columbia Dreissenid Mussel Lake Monitoring Field Protocol', 'parameter': 'pH', 'parameter_unit': 'ph units', 'range': '-2.0 to 16.0 pH', 'resolution': '0.1 pH', 'serial_number': 'Not specified', 'time_zone': 'MT'}, {'accuracy': 'N/A', 'calibration': 'N/A', 'instrument_manufacturer': 'N/A', 'instrument_model': 'N/A', 'instrument_type': 'Secchi Disk', 'notes_method': 'As per British Columbia Dreissenid Mussel Lake Monitoring Field Protocol', 'parameter': 'water_clarity_secchi', 'parameter_unit': 'metres', 'range': 'N/A', 'resolution': 'N/A', 'serial_number': 'N/A', 'time_zone': 'MT'}]
Position0
Recent qa date2023-12-14
Resource citationEast Kootenay Invasive Species Council. (2023). Field Water Quality (2022-06-01 to 2023-09-11) Loon Lake [Resource]. Columbia Basin Water Hub. https://doi.org/10.48511/BXQD-AT68
Resource data disclaimerNo warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose. It was not specified if instruments were calibrated.
Resource locationMeasurements taken at boat launch on Loon Lake.
Site[{'datum': 'Not specified', 'elevation': 1, 'latitude': 49.11244, 'longitude': -115.10854, 'site_id': 'boat_launch_1', 'site_name': 'Boat Launch', 'waterbody': 'Loon Lake', 'waterbody_type': 'lake'}]
Size1.4 KiB
Stateactive
Url typeupload
Waterhub gradeCommunity Research Grade
Citation (Required) East Kootenay Invasive Species Council. (2023). Field Water Quality (2022-06-01 to 2023-09-11) Loon Lake [Resource]. Columbia Basin Water Hub. https://doi.org/10.48511/BXQD-AT68
Resource Location Measurements taken at boat launch on Loon Lake.
Data Collection Information EKISC follows the British Columbia Dreissenid Mussel Lake Monitoring Field Protocol which is updated annually and provided by the Ministry of Environment. The protocol sets provincial standards for plankton tow sample collection, preservation, ancillary data collection, and shipment of samples.
Data Processing The Water Hub has performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data Disclaimer No warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose. It was not specified if instruments were calibrated.
Water Hub Data Grade Community Research Grade
Date of Most Recent Water Hub QA/QC 2023-12-14
Loading Status Table was successfully loaded: 4 rows
Datastore Status pending
Data type General

Data Dictionary

Column Type Label Description BODC ID
date_time text
site_id text
site_latitude text
site_longitude text
notes text
water_temperature text
water_temperature_units text
pH text PHXXPR01 pH per unit volume of the water body by pH electrode SDN:P01::PHXXPR01
pH_units text
water_clarity_secchi text Secchi Estimate of the transparency of the surface water based upon the distance below the ship at which a standard black and white disk becomes visible. SDN:P01::SECCSDNX
water_clarity_secchi_units text
water_hub_qa_qc text

Site

boat_launch_1
Field Value
Site ID boat_launch_1
Site Name Boat Launch
Waterbody Type Lake
Waterbody Loon Lake
Site Latitude 49.11244
Site Longitude -115.10854
Location Coordinate System Not specified
Site Elevation (masl) 1

Parameter

Water Temperature
Field Value
Parameter Water Temperature
Time Zone MT
Unit of Measurement degrees Celsius
Instrument Type Other
Other pH Pen
Instrument Manufacturer Hanna
Instrument Model HI98127
Serial Number Not specified
Instrument Accuracy ±0.5°C
Range -5.0 to 60.0°C
Resolution 0.1°C
Calibration Notes Not specified
Notes on Method As per British Columbia Dreissenid Mussel Lake Monitoring Field Protocol
pH
Field Value
Parameter pH
Time Zone MT
Unit of Measurement pH units
Instrument Type Other
Other pH Pen
Instrument Manufacturer Hanna
Instrument Model HI98127
Serial Number Not specified
Instrument Accuracy ±0.1 pH
Range -2.0 to 16.0 pH
Resolution 0.1 pH
Calibration Notes Not specified
Notes on Method As per British Columbia Dreissenid Mussel Lake Monitoring Field Protocol
water_clarity_secchi
Field Value
Parameter water_clarity_secchi
Time Zone MT
Unit of Measurement metres
Instrument Type Secchi Disk
Instrument Manufacturer N/A
Instrument Model N/A
Serial Number N/A
Instrument Accuracy N/A
Range N/A
Resolution N/A
Calibration Notes N/A
Notes on Method As per British Columbia Dreissenid Mussel Lake Monitoring Field Protocol