Resource metadata

Field Value
Data last updated February 11, 2025
Metadata last updated February 11, 2025
Created December 24, 2021
Format CSV
License CC-BY-SA-4.0
Data collection infoEKISC follows the British Columbia Dreissenid Mussel Lake Monitoring Field Protocol which is updated annually and provided by the Ministry of Environment. The protocol sets provincial standards for plankton tow sample collection, preservation, ancillary data collection, and shipment of samples.
Data processingThe Water Hub has performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data typenon-lab
Datastore activeTrue
Datastore contains all records of source fileFalse
Datastore statuspending
Has viewsTrue
Hash60ea2bed571a519fb03e290212c07a21
Header row1
Id05ae6773-e72d-4c30-b839-43f453f208e7
Load statusTable was successfully loaded: 22 rows
Mimetypetext/csv
Package ida68800ec-43ac-4e7f-b583-6ff49c89ea64
Parameter[{'accuracy': '±0.5°C', 'calibration': 'Not specified', 'instrument_manufacturer': 'Hanna', 'instrument_model': 'HI98127', 'instrument_type': 'Other', 'instrument_type_other': 'pH Pen', 'notes_method': 'As per British Columbia Dreissenid Mussel Lake Monitoring Field Protocol', 'parameter': 'Water Temperature', 'parameter_unit': 'degrees celsius', 'range': '-5.0 to 60.0°C', 'resolution': '0.1°C', 'serial_number': 'Not specified', 'time_zone': 'MT'}, {'accuracy': '±0.1 pH', 'calibration': 'Not specified', 'instrument_manufacturer': 'Hanna', 'instrument_model': 'HI98127', 'instrument_type': 'Other', 'instrument_type_other': 'pH Pen', 'notes_method': 'As per British Columbia Dreissenid Mussel Lake Monitoring Field Protocol', 'parameter': 'pH', 'parameter_unit': 'ph units', 'range': '-2.0 to 16.0 pH', 'resolution': '0.1 pH', 'serial_number': 'Not specified', 'time_zone': 'MT'}, {'accuracy': 'N/A', 'calibration': 'N/A', 'instrument_manufacturer': 'Not specified', 'instrument_model': 'N/A', 'instrument_type': 'Secchi Disk', 'notes_method': 'As per British Columbia Dreissenid Mussel Lake Monitoring Field Protocol', 'parameter': 'water_clarity_secchi', 'parameter_unit': 'metres', 'range': 'N/A', 'resolution': 'N/A', 'serial_number': 'N/A', 'time_zone': 'MT'}]
Position0
Recent qa date2023-12-14
Resource citationEast Kootenay Invasive Species Society. (2021). Field Water Quality (2019-06-18 to 2024-09-10) St. Mary Lake. Columbia Basin Water Hub [Resource]. Cranbrook, BC. (DOI)
Resource data disclaimerNo warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose. It was not specified if instruments were calibrated.
Resource locationVarious locations across St. Mary Lake are included.
Site[{'datum': 'UNKWN', 'latitude': 49.60754, 'longitude': -116.17175, 'site_id': 'stmary_boatlaunch', 'site_name': 'Boat Launch', 'waterbody': 'St. Mary Lake', 'waterbody_type': 'lake'}]
Size4.2 KiB
Stateactive
Url typeupload
Waterhub gradeCommunity Research Grade
Citation (Required) East Kootenay Invasive Species Society. (2021). Field Water Quality (2019-06-18 to 2024-09-10) St. Mary Lake. Columbia Basin Water Hub [Resource]. Cranbrook, BC. (DOI)
Resource Location Various locations across St. Mary Lake are included.
Data Collection Information EKISC follows the British Columbia Dreissenid Mussel Lake Monitoring Field Protocol which is updated annually and provided by the Ministry of Environment. The protocol sets provincial standards for plankton tow sample collection, preservation, ancillary data collection, and shipment of samples.
Data Processing The Water Hub has performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data Disclaimer No warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose. It was not specified if instruments were calibrated.
Water Hub Data Grade Community Research Grade
Date of Most Recent Water Hub QA/QC 2023-12-14
Loading Status Table was successfully loaded: 22 rows
Datastore Status pending
Data type General

Data Dictionary

Column Type Label Description BODC ID
date_time text
site_id text
latitude text
longitude text
notes text
water_temperature text
water_temperature_units text
pH text PHXXPR01 pH per unit volume of the water body by pH electrode SDN:P01::PHXXPR01
pH_units text
water_clarity_secchi text Secchi Estimate of the transparency of the surface water based upon the distance below the ship at which a standard black and white disk becomes visible. SDN:P01::SECCSDNX
water_clarity_secchi_units text
water_hub_qa_qc text

Site

stmary_boatlaunch
Field Value
Site ID stmary_boatlaunch
Site Name Boat Launch
Waterbody Type Lake
Waterbody St. Mary Lake
Site Latitude 49.60754
Site Longitude -116.17175
Location Coordinate System UNKWN
Site Elevation (masl)

Parameter

Water Temperature
Field Value
Parameter Water Temperature
Time Zone MT
Unit of Measurement degrees Celsius
Instrument Type Other
Other pH Pen
Instrument Manufacturer Hanna
Instrument Model HI98127
Serial Number Not specified
Instrument Accuracy ±0.5°C
Range -5.0 to 60.0°C
Resolution 0.1°C
Calibration Notes Not specified
Notes on Method As per British Columbia Dreissenid Mussel Lake Monitoring Field Protocol
pH
Field Value
Parameter pH
Time Zone MT
Unit of Measurement pH units
Instrument Type Other
Other pH Pen
Instrument Manufacturer Hanna
Instrument Model HI98127
Serial Number Not specified
Instrument Accuracy ±0.1 pH
Range -2.0 to 16.0 pH
Resolution 0.1 pH
Calibration Notes Not specified
Notes on Method As per British Columbia Dreissenid Mussel Lake Monitoring Field Protocol
water_clarity_secchi
Field Value
Parameter water_clarity_secchi
Time Zone MT
Unit of Measurement metres
Instrument Type Secchi Disk
Instrument Manufacturer Not specified
Instrument Model N/A
Serial Number N/A
Instrument Accuracy N/A
Range N/A
Resolution N/A
Calibration Notes N/A
Notes on Method As per British Columbia Dreissenid Mussel Lake Monitoring Field Protocol