Resource metadata

Field Value
Data last updated December 7, 2023
Metadata last updated January 15, 2024
Created March 21, 2022
Format CSV
License CC-BY-NC-SA-4.0
Data collection infoConductivity and temperature are measured four times each day using an Onset Hobo U24 Conductivity data logger. Actual conductivity values have been converted to specific conductivity using the Conductivity Assistant provided by Hoboware Pro.
Data processingThe Water Hub has performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data typenon-lab
Datastore activeTrue
Datastore statuspending
Has viewsTrue
Hashc3cb0d3f833bd30c1de7c1bdf4e2237e
Header row1
Id1b155815-4cde-4434-8029-ef1eec8700f7
Load statusTable was successfully loaded: 6677 rows
Mimetypetext/csv
On same domainTrue
Package id463fcf93-0770-4288-bbc3-2ceefbc9f3fa
Parameter[{'accuracy': '3% of reading, or 20 µS/cm, whichever is greater, using Conductivity Data Assistant and calibration measurements', 'calibration': 'Checked against Conductivity Standard 1413uS/cm. Low range settings were used.', 'instrument_manufacturer': 'Onset HOBO', 'instrument_model': 'U24', 'instrument_type': 'Data Logger', 'notes_method': 'Converted to specific conductivity using Conductivity Assistant probided by Hoboware Pro. ', 'parameter': 'specific conductivity', 'parameter_unit': 'microsiemens per centimetre', 'range': '0 to 10,000 µS/cm', 'resolution': 'n/a', 'serial_number': 'LGR S/N: 20213608, SEN S/N: 20213608', 'time_zone': 'PT'}, {'accuracy': '0.1°C (0.2°F) at 25°C', 'calibration': 'Factory calibrated', 'instrument_manufacturer': 'Onset HOBO', 'instrument_model': 'U24', 'instrument_type': 'Data Logger', 'notes_method': 'N/A', 'parameter': 'Water Temperature', 'parameter_unit': 'degrees celsius', 'range': '-2° to 36°C', 'resolution': 'n/a', 'serial_number': 'LGR S/N: 20213608, SEN S/N: 20213608', 'time_zone': 'PT'}]
Position2
Resource citationRossland Streamkeepers. (2021). Conductivity and Temperature (2018-03-15 to 2021-03-02) Trail Creek. Columbia Basin Water Hub. [Resource] Rossland. https://doi.org/10.48511/RCTE-1N70
Resource data disclaimerNo warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Resource locationUpper Trail Creek, TCW02 monitoring station
Site[{'datum': 'NAD83', 'elevation': 962, 'latitude': 49.073417, 'longitude': -117.801833, 'site_id': 'TCW02', 'site_name': 'Upper Trail Creek', 'waterbody': 'Trail Creek', 'waterbody_type': 'stream/river'}]
Size853.5 KiB
Stateactive
Url typeupload
Waterhub gradeTechnical Research Grade
upload
Citation (Required) Rossland Streamkeepers. (2021). Conductivity and Temperature (2018-03-15 to 2021-03-02) Trail Creek. Columbia Basin Water Hub. [Resource] Rossland. https://doi.org/10.48511/RCTE-1N70
Resource Location Upper Trail Creek, TCW02 monitoring station
Data Collection Information Conductivity and temperature are measured four times each day using an Onset Hobo U24 Conductivity data logger. Actual conductivity values have been converted to specific conductivity using the Conductivity Assistant provided by Hoboware Pro.
Data Processing The Water Hub has performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data Disclaimer No warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Water Hub Data Grade Technical Research Grade
Date of Most Recent Water Hub QA/QC
Loading Status Table was successfully loaded: 6677 rows
Datastore Status pending
Data type General

Data Dictionary

Column Type Label Description BODC ID
date_time timestamp
site_id text
latitude float8
longitude float8
notes float8
specific_conductivity float8
specific_conductivity_units text
water_temperature float8
water_temperature_units text
water_hub_qa_qc float8

Site

TCW02
Field Value
Site ID TCW02
Site Name Upper Trail Creek
Waterbody Type Stream/River
Waterbody Trail Creek
Site Latitude 49.073417
Site Longitude -117.801833
Location Coordinate System NAD83
Site Elevation (masl) 962

Parameter

specific conductivity
Field Value
Parameter specific conductivity
Time Zone PT
Unit of Measurement microSiemens per centimetre
Instrument Type Data Logger
Instrument Manufacturer Onset HOBO
Instrument Model U24
Serial Number LGR S/N: 20213608, SEN S/N: 20213608
Instrument Accuracy 3% of reading, or 20 µS/cm, whichever is greater, using Conductivity Data Assistant and calibration measurements
Range 0 to 10,000 µS/cm
Resolution n/a
Calibration Notes Checked against Conductivity Standard 1413uS/cm. Low range settings were used.
Notes on Method Converted to specific conductivity using Conductivity Assistant probided by Hoboware Pro.
Water Temperature
Field Value
Parameter Water Temperature
Time Zone PT
Unit of Measurement degrees Celsius
Instrument Type Data Logger
Instrument Manufacturer Onset HOBO
Instrument Model U24
Serial Number LGR S/N: 20213608, SEN S/N: 20213608
Instrument Accuracy 0.1°C (0.2°F) at 25°C
Range -2° to 36°C
Resolution n/a
Calibration Notes Factory calibrated
Notes on Method N/A