Resource metadata

Field Value
Data last updated March 17, 2024
Metadata last updated March 17, 2024
Created September 13, 2021
Format CSV
License CC-BY-SA-4.0
Ckan urlhttps://data.cbwaterhub.ca
Data collection infoTemperature and pH are measured using a Hanna Industries pen meter (HI98129) within 2-4” of the surface. Secchi depths are collected where there is sufficient depth to measure from the sampling location. Data collection is consistent with the Invasive Mussel Field Protocol prepared by the Ecosystems Branch, BC Ministry of Environment and Climate Change Strategy.
Data processingThe Water Hub has performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data typenon-lab
Datastore activeTrue
Datastore contains all records of source fileTrue
Datastore statuspending
Has viewsTrue
Hash58b33c72e75a583a3b12ab2d94976d9b
Header row1
Id2d513bec-6735-45f9-8685-d7ca3fae08d3
Ignore hashTrue
Load statusTable was successfully loaded: 19 rows
Mimetypetext/csv
Original urlhttps://data.cbwaterhub.ca/dataset/7104fd6e-3ef5-4fb1-b1c2-897c980901c7/resource/2d513bec-6735-45f9-8685-d7ca3fae08d3/download/csiss_waterquality_troutlakedenverstreet_20170718_20230907.csv
Package id7104fd6e-3ef5-4fb1-b1c2-897c980901c7
Parameter[{'accuracy': '±0.5°C', 'calibration': 'N/A', 'instrument_manufacturer': 'HANNA Instruments', 'instrument_model': 'HI98129', 'instrument_type': 'Portable Multiparameter Meter', 'notes_method': 'Low range combination meter', 'parameter': 'Water Temperature', 'parameter_unit': 'degrees celsius', 'range': '-5.0 to 60.0°C', 'resolution': '0.1°C', 'time_zone': 'MT'}, {'accuracy': '±0.05 pH', 'calibration': 'pH is calibrated weekly', 'instrument_manufacturer': 'HANNA Instruments', 'instrument_model': 'HI98129', 'instrument_type': 'Portable Multiparameter Meter', 'notes_method': 'Low range combination meter', 'parameter': 'pH', 'parameter_unit': 'ph units', 'range': '0.00 to 14.00 pH', 'resolution': '0.01 pH', 'time_zone': 'MT'}, {'accuracy': 'N/A', 'calibration': 'N/A', 'instrument_manufacturer': 'N/A', 'instrument_model': 'N/A', 'instrument_type': 'Secchi Disk', 'notes_method': 'Methodology consistent with Invasive Mussel Field Protocol prepared by the Ecosystems Branch, BC Ministry of Environment and Climate Change Strategy', 'parameter': 'depth', 'parameter_unit': 'metres', 'range': 'N/A', 'resolution': 'N/A', 'time_zone': 'N/A'}]
Position0
Recent qa date2024-03-17
Resource citationColumbia Shuswap Invasive Species Society. (2023). Water Quality (2017-07-18 to 2023-09-07) Trout Lake at Denver St. Columbia Basin Water Hub [Resource]. Revelstoke, BC. https://doi.org/10.48511/ENCZ-EY10
Resource data disclaimerNo warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. Instrument accuracy may be limited. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Resource id2d513bec-6735-45f9-8685-d7ca3fae08d3
Resource locationTrout Lake at Denver St, deep dock at western end (inflow end) of lake. One measurement for Trout Lake at Gerrard near the lake outflow is also included.
Set url typeFalse
Site[{'datum': 'WGS84', 'elevation': 722, 'latitude': 50.644733, 'longitude': -117.535707, 'site_id': 'Trout Lake at Denver St', 'site_name': 'Denver St', 'waterbody': 'Trout Lake', 'waterbody_type': 'lake'}, {'datum': 'WGS84', 'elevation': 722, 'latitude': 50.511244, 'longitude': -117.281584, 'site_id': 'Trout Lake at Gerrard', 'site_name': 'Gerrard', 'waterbody': 'Trout Lake', 'waterbody_type': 'lake'}]
Size3.3 KiB
Stateactive
Task created2024-03-17 15:43:26.429158
Url typeupload
Waterhub gradeCommunity Research Grade
Citation (Required) Columbia Shuswap Invasive Species Society. (2023). Water Quality (2017-07-18 to 2023-09-07) Trout Lake at Denver St. Columbia Basin Water Hub [Resource]. Revelstoke, BC. https://doi.org/10.48511/ENCZ-EY10
Resource Location Trout Lake at Denver St, deep dock at western end (inflow end) of lake. One measurement for Trout Lake at Gerrard near the lake outflow is also included.
Data Collection Information Temperature and pH are measured using a Hanna Industries pen meter (HI98129) within 2-4” of the surface. Secchi depths are collected where there is sufficient depth to measure from the sampling location. Data collection is consistent with the Invasive Mussel Field Protocol prepared by the Ecosystems Branch, BC Ministry of Environment and Climate Change Strategy.
Data Processing The Water Hub has performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data Disclaimer No warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. Instrument accuracy may be limited. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Water Hub Data Grade Community Research Grade
Date of Most Recent Water Hub QA/QC 2024-03-17
Loading Status Table was successfully loaded: 19 rows
Datastore Status pending
Data type General

Data Dictionary

Column Type Label Description BODC ID
date_time text
site_id text
latitude text
longitude text
notes text
water_temperature text
water_temperature_units text
pH text PHXXPR01 pH per unit volume of the water body by pH electrode SDN:P01::PHXXPR01
pH_units text
depth text Depth The length of wire between the ship and an object being lowered from a winch, which is assumed or wire-angle corrected to be the vertical distance between the ship and the object. SDN:P01::DEPHWO01
depth_units text
water_hub_qa_qc text

Site

Trout Lake at Denver St
Field Value
Site ID Trout Lake at Denver St
Site Name Denver St
Waterbody Type Lake
Waterbody Trout Lake
Site Latitude 50.644733
Site Longitude -117.535707
Location Coordinate System WGS84
Site Elevation (masl) 722
Trout Lake at Gerrard
Field Value
Site ID Trout Lake at Gerrard
Site Name Gerrard
Waterbody Type Lake
Waterbody Trout Lake
Site Latitude 50.511244
Site Longitude -117.281584
Location Coordinate System WGS84
Site Elevation (masl) 722

Parameter

Water Temperature
Field Value
Parameter Water Temperature
Time Zone MT
Unit of Measurement degrees Celsius
Instrument Type Portable Multiparameter Meter
Instrument Manufacturer HANNA Instruments
Instrument Model HI98129
Instrument Accuracy ±0.5°C
Range -5.0 to 60.0°C
Resolution 0.1°C
Calibration Notes N/A
Notes on Method Low range combination meter
pH
Field Value
Parameter pH
Time Zone MT
Unit of Measurement pH units
Instrument Type Portable Multiparameter Meter
Instrument Manufacturer HANNA Instruments
Instrument Model HI98129
Instrument Accuracy ±0.05 pH
Range 0.00 to 14.00 pH
Resolution 0.01 pH
Calibration Notes pH is calibrated weekly
Notes on Method Low range combination meter
depth
Field Value
Parameter depth
Time Zone N/A
Unit of Measurement metres
Instrument Type Secchi Disk
Instrument Manufacturer N/A
Instrument Model N/A
Instrument Accuracy N/A
Range N/A
Resolution N/A
Calibration Notes N/A
Notes on Method Methodology consistent with Invasive Mussel Field Protocol prepared by the Ecosystems Branch, BC Ministry of Environment and Climate Change Strategy