You're currently viewing an old version of this dataset. To see the current version, click here.
Groundwater (2013-10-12 to 2021-03-10) LLC VOW 01
Download: llc_waterlevel_watertemp_aquifer603_vow01_20131012_20210310.xlsx
This resource is part of the Living Lakes Canada Upper Columbia Basin Groundwater Monitoring Program, and contains a groundwater monitoring record for LLC VOW 1 from 2013-10-12 to 2020-10-04. Water levels are reported in meters below ground surface. This resource will be updated periodically to add new data.
Resource metadata
Field | Value |
Data last updated | June 19, 2022 |
Metadata last updated | June 19, 2022 |
Created | March 16, 2021 |
Format | XLSX |
License | CC-BY-NC-SA-4.0 |
Data collection info | Daily water level data were collected with a HOBO U20 water level data logger. The water level is determined by continuously collecting the absolute pressure of the water column above a sensor, compensating it for atmospheric pressure, and calibrating it with reference water levels that are collected manually. The atmospheric pressure is measured by a HOBO U20 level logger (0- 4m range) that is installed in the airspace at the top of the wellhead. Manual water level level measurements were collected using either a Heron or Solinst water level tape (sounding tape). |
Data processing | Data compensation and water level referencing were completed using HOBOWare Pro software. For the conversion of pressure to water level, the water density of freshwater is adjusted for water temperature. Pressures are converted to water level based on manual water level readings using a water level tape. The pressure data were reviewed to ensure they are within the factory calibrated range of the sensor. Water level time series and the manual and logger data were compared to identify any gross errors or potential instrument drift. Data collected prior to 2017-05-30 were not verified. Data from 2018-04-16 to 2018-05-07 were shifted to match the time series trends and account for instrument errors. |
Datastore status | pending |
Has views | True |
Hash | 1d1f18f962e6661bfe93575ce240205a |
Header row | 1 |
Id | a42a793d-0a1c-4a8d-a126-3bab6870f925 |
Load status | Reading tabular file llc_waterlevel_watertemp_aquifer603_vow01_20131012_20210310.xlsx (xlsx) |
Mimetype | application/vnd.openxmlformats-officedocument.spreadsheetml.sheet |
Package id | b90f4bf2-9a3f-464c-afcf-eae77e433335 |
Resource citation | Living Lakes Canada Upper Columbia Basin Groundwater Monitoring Program. (2021) Groundwater (2013-10-12 to 2021-03-10) LLC VOW 01. Columbia Basin Water Hub. (Resource) Invermere. (DOI). |
Resource data disclaimer | No warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose themselves. |
Resource location | District of Invermere; Althamer near wastewater treatment plant |
Size | 4.5 MiB |
State | active |
Url type | upload |
Waterhub certified | Certified |
Waterhub grade | Technical Research Grade |
upload | |
Citation (Required) | Living Lakes Canada Upper Columbia Basin Groundwater Monitoring Program. (2021) Groundwater (2013-10-12 to 2021-03-10) LLC VOW 01. Columbia Basin Water Hub. (Resource) Invermere. (DOI). |
Resource Location | District of Invermere; Althamer near wastewater treatment plant |
Data Collection Information | Daily water level data were collected with a HOBO U20 water level data logger. The water level is determined by continuously collecting the absolute pressure of the water column above a sensor, compensating it for atmospheric pressure, and calibrating it with reference water levels that are collected manually. The atmospheric pressure is measured by a HOBO U20 level logger (0- 4m range) that is installed in the airspace at the top of the wellhead. Manual water level level measurements were collected using either a Heron or Solinst water level tape (sounding tape). |
Data Processing | Data compensation and water level referencing were completed using HOBOWare Pro software. For the conversion of pressure to water level, the water density of freshwater is adjusted for water temperature. Pressures are converted to water level based on manual water level readings using a water level tape. The pressure data were reviewed to ensure they are within the factory calibrated range of the sensor. Water level time series and the manual and logger data were compared to identify any gross errors or potential instrument drift. Data collected prior to 2017-05-30 were not verified. Data from 2018-04-16 to 2018-05-07 were shifted to match the time series trends and account for instrument errors. |
Data Disclaimer | No warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose themselves. |
Water Hub Data Grade | Technical Research Grade |
Date of Most Recent Water Hub QA/QC | |
Loading Status | Reading tabular file llc_waterlevel_watertemp_aquifer603_vow01_20131012_20210310.xlsx (xlsx) |
Datastore Status | pending |
Data type |
Site
No data available
Parameter