Resource metadata

Field Value
Data last updated March 14, 2024
Metadata last updated March 14, 2024
Created November 25, 2022
Format CSV
License CC-BY-SA-4.0
Data collection infoTemperature and pH are measured using a Hanna Industries pen meter (HI98129) within 2-4” of the surface. Secchi depths are collected where there is sufficient depth to measure from the sampling location. Data collection is consistent with the Invasive Mussel Field Protocol prepared by the Ecosystems Branch, BC Ministry of Environment and Climate Change Strategy.
Data processingThe Water Hub has performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data typenon-lab
Datastore activeTrue
Datastore statusready
Has viewsTrue
Hash8e6ba018804ea3204adf5c50db773e09
Header row1
Ide0dd689b-b4a8-46f1-bb4a-841920d5cd57
Load statusTable was successfully loaded: 7 rows
Mimetypetext/csv
On same domainTrue
Package idca138ffc-cfdb-4268-8cb0-332b257fa8ad
Parameter[{'accuracy': '±0.5°C', 'calibration': 'N/A', 'instrument_manufacturer': 'HANNA Instruments', 'instrument_model': 'HI98129', 'instrument_type': 'Portable Multiparameter Meter', 'notes_method': 'Low range combination meter', 'parameter': 'Water Temperature', 'parameter_unit': 'degrees celsius', 'range': '-5.0 to 60.0°C', 'resolution': '0.1°C', 'time_zone': 'MT'}, {'accuracy': '±0.05 pH', 'calibration': 'pH is calibrated weekly', 'instrument_manufacturer': 'HANNA Instruments', 'instrument_model': 'HI98129', 'instrument_type': 'Portable Multiparameter Meter', 'notes_method': 'Low range combination meter', 'parameter': 'pH', 'parameter_unit': 'ph units', 'range': '0.00 to 14.00 pH', 'resolution': '0.01 pH', 'time_zone': 'MT'}, {'accuracy': 'N/A', 'calibration': 'N/A', 'instrument_manufacturer': 'N/A', 'instrument_model': 'N/A', 'instrument_type': 'Secchi Disk', 'notes_method': 'Methodology consistent with Invasive Mussel Field Protocol prepared by the Ecosystems Branch, BC Ministry of Environment and Climate Change Strategy', 'parameter': 'water_clarity_secchi', 'parameter_unit': 'metres', 'range': 'N/A', 'resolution': 'N/A', 'time_zone': 'N/A'}]
Recent qa date2024-03-14
Resource citationCSISS. (2023). Field Water Quality (2022-07-21 to 2023-09-19) Cedar Lake at Recreation Site [Resource]. Columbia Basin Water Hub. DOI
Resource data disclaimerNo warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. Instrument accuracy may be limited. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Resource ide0dd689b-b4a8-46f1-bb4a-841920d5cd57
Resource locationCedar Lake at recreation site. Shallow dock on small marl lake with well-used campground and rec site.
Site[{'datum': 'Not specified', 'elevation': 1, 'latitude': 51.262531, 'longitude': -116.982755, 'site_id': 'cedar_lake', 'site_name': 'Cedar Lake Rec Site', 'waterbody': 'Cedar Lake', 'waterbody_type': 'lake'}]
Size1 KiB
Stateactive
Url typeupload
Waterhub gradeCommunity Research Grade
upload
Citation (Required) CSISS. (2023). Field Water Quality (2022-07-21 to 2023-09-19) Cedar Lake at Recreation Site [Resource]. Columbia Basin Water Hub. DOI
Resource Location Cedar Lake at recreation site. Shallow dock on small marl lake with well-used campground and rec site.
Data Collection Information Temperature and pH are measured using a Hanna Industries pen meter (HI98129) within 2-4” of the surface. Secchi depths are collected where there is sufficient depth to measure from the sampling location. Data collection is consistent with the Invasive Mussel Field Protocol prepared by the Ecosystems Branch, BC Ministry of Environment and Climate Change Strategy.
Data Processing The Water Hub has performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data Disclaimer No warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. Instrument accuracy may be limited. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Water Hub Data Grade Community Research Grade
Date of Most Recent Water Hub QA/QC 2024-03-14
Loading Status Table was successfully loaded: 7 rows
Datastore Status ready
Data type General

Data Dictionary

Column Type Label Description BODC ID
date_time text
site_id text
latitude float8
longitude float8
notes float8
water_temperature float8
water_temperature_units text
pH float8
pH_units text
water_clarity_secchi float8
water_clarity_secchi_units text
water_hub_qa_qc float8

Site

cedar_lake
Field Value
Site ID cedar_lake
Site Name Cedar Lake Rec Site
Waterbody Type Lake
Waterbody Cedar Lake
Site Latitude 51.262531
Site Longitude -116.982755
Location Coordinate System Not specified
Site Elevation (masl) 1

Parameter

Water Temperature
Field Value
Parameter Water Temperature
Time Zone MT
Unit of Measurement degrees Celsius
Instrument Type Portable Multiparameter Meter
Instrument Manufacturer HANNA Instruments
Instrument Model HI98129
Instrument Accuracy ±0.5°C
Range -5.0 to 60.0°C
Resolution 0.1°C
Calibration Notes N/A
Notes on Method Low range combination meter
pH
Field Value
Parameter pH
Time Zone MT
Unit of Measurement pH units
Instrument Type Portable Multiparameter Meter
Instrument Manufacturer HANNA Instruments
Instrument Model HI98129
Instrument Accuracy ±0.05 pH
Range 0.00 to 14.00 pH
Resolution 0.01 pH
Calibration Notes pH is calibrated weekly
Notes on Method Low range combination meter
water_clarity_secchi
Field Value
Parameter water_clarity_secchi
Time Zone N/A
Unit of Measurement metres
Instrument Type Secchi Disk
Instrument Manufacturer N/A
Instrument Model N/A
Instrument Accuracy N/A
Range N/A
Resolution N/A
Calibration Notes N/A
Notes on Method Methodology consistent with Invasive Mussel Field Protocol prepared by the Ecosystems Branch, BC Ministry of Environment and Climate Change Strategy