Resource metadata

Field Value
Data last updated December 6, 2023
Metadata last updated February 18, 2024
Created March 19, 2021
Format CSV
License CC-BY-NC-SA-4.0
Data collection infoTemperature measurements are taken in-stream. Water samples are collected, and analysed in batches on the dates noted as "Analysis" in the "Remarks" column. Instruments used are calibrated as per manufacturer instructions and standards.
Data processingThe Water Hub has performed a preliminary QA/QC protocol on this data and has flagged a value that was identified as unexpected, but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data typenon-lab
Datastore activeTrue
Datastore contains all records of source fileFalse
Datastore statusready
Has viewsTrue
Hashbeaf84e39409816ca6181ac30ed919ba
Header row1
Id7efb0cd1-db02-4854-a0bc-83d9ffaca65e
Load statusERROR: Unable to find a usable engine; tried using: 'sqlalchemy'. A suitable version of sqlalchemy is required for sql I/O support. Trying to import the above resulted in these errors: - Pandas requires version '1.4.16' or newer of 'sqlalchemy' (version '1.3.5' currently installed).
Mimetypetext/csv
Package id524ffafb-a402-46a9-aeb1-510e95e544be
Parameter[{'accuracy': 'Unavailable', 'calibration': 'Unavailable', 'instrument_manufacturer': 'Unavailable', 'instrument_model': 'Unavailable', 'instrument_type': 'Other', 'instrument_type_other': 'Unavailable', 'notes_method': 'In stream', 'parameter': 'Water Temperature', 'parameter_unit': 'degrees celsius', 'range': 'Unavailable', 'resolution': 'n/a', 'serial_number': 1, 'time_zone': 'PT'}, {'accuracy': '±0.01 pH', 'calibration': 'Calibrated before each use', 'instrument_manufacturer': 'Oaktron', 'instrument_model': 'pH 200', 'instrument_type': 'N/A', 'notes_method': 'bottle dip', 'parameter': 'pH', 'parameter_unit': 'ph units', 'range': '0.00 to 14.00 pH', 'resolution': 'n/a', 'serial_number': 1, 'time_zone': 'PT'}, {'accuracy': 'Unavailable', 'calibration': 'Conductivity Bridge calibrated annually using standard solution', 'instrument_manufacturer': 'AMRE', 'instrument_model': '2300', 'instrument_type': 'N/A', 'notes_method': 'bottle dip', 'parameter': 'specific conductivity', 'parameter_unit': 'micromhos per centimetre', 'range': 'Unavailable', 'resolution': 'n/a', 'serial_number': 1, 'time_zone': 'PT'}, {'accuracy': '± 2 % of reading plus stray light', 'calibration': 'Calibrated before each use', 'instrument_manufacturer': 'Hach', 'instrument_model': '2100Q', 'instrument_type': 'N/A', 'notes_method': 'bottle dip', 'parameter': 'turbidity', 'parameter_unit': 'ntu', 'range': '0-1000', 'resolution': 'n/a', 'serial_number': 1, 'time_zone': 'PT'}, {'accuracy': 'unavailable', 'calibration': 'Calibrated before each use', 'instrument_manufacturer': 'unavailable', 'instrument_model': 'unavailable', 'instrument_type': 'N/A', 'notes_method': 'bottle dip', 'parameter': 'conductivity', 'parameter_unit': 'microsiemens per centimetre', 'range': 'unavailable', 'resolution': 'N/A', 'serial_number': 1, 'time_zone': 'PT'}, {'accuracy': 'Unavailable', 'calibration': 'Calibrated before each use', 'instrument_manufacturer': 'Unavailable', 'instrument_model': 'Unavailable', 'instrument_type': 'Other', 'instrument_type_other': 'Unavailable', 'notes_method': 'bottle dip', 'parameter': 'temperature at analysis', 'parameter_unit': 'degrees celsius', 'range': 'Unavailable', 'resolution': 'N/A', 'serial_number': 1, 'time_zone': 'PT'}]
Position0
Resource citationSlocan Lake Stewardship Society. (2021) Carpenter Creek Water Quality Monitoring 2017-2021. Columbia Basin Water Hub. [Resource]. New Denver. (DOI)
Resource data disclaimerNo warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. Some metadata may be missing from this file. Instrument accuracy may be limited. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Resource locationCarpenter Creek, New Denver BC
Site[{'datum': 'WGS84', 'elevation': 555, 'latitude': 49.98932, 'longitude': -117.37212, 'site_id': 'carpenter_creek', 'site_name': 'Carpenter Creek', 'waterbody': 'Carpenter Creek', 'waterbody_type': 'stream/river'}]
Size27 KiB
Stateactive
Url typeupload
Waterhub gradeCommunity Research Grade
Citation (Required) Slocan Lake Stewardship Society. (2021) Carpenter Creek Water Quality Monitoring 2017-2021. Columbia Basin Water Hub. [Resource]. New Denver. (DOI)
Resource Location Carpenter Creek, New Denver BC
Data Collection Information Temperature measurements are taken in-stream. Water samples are collected, and analysed in batches on the dates noted as "Analysis" in the "Remarks" column. Instruments used are calibrated as per manufacturer instructions and standards.
Data Processing The Water Hub has performed a preliminary QA/QC protocol on this data and has flagged a value that was identified as unexpected, but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data Disclaimer No warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. Some metadata may be missing from this file. Instrument accuracy may be limited. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Water Hub Data Grade Community Research Grade
Date of Most Recent Water Hub QA/QC
Loading Status ERROR: Unable to find a usable engine; tried using: 'sqlalchemy'. A suitable version of sqlalchemy is required for sql I/O support. Trying to import the above resulted in these errors: - Pandas requires version '1.4.16' or newer of 'sqlalchemy' (version '1.3.5' currently installed).
Datastore Status ready
Data type General

Data Dictionary

Column Type Label Description BODC ID
date_time timestamp
site_id text
latitude float8
longitude float8
notes text
water_temperature float8
water_temperature_units text
pH float8
pH_units text
specific_conductivity float8
specific_conductivity_units text
turbidity float8
turbidity_units text
conductivity float8
conductivity_units text
temperature_at_analyis float8
temperature_at_analyis_units text
water_hub_qa_qc text

Site

carpenter_creek
Field Value
Site ID carpenter_creek
Site Name Carpenter Creek
Waterbody Type Stream/River
Waterbody Carpenter Creek
Site Latitude 49.98932
Site Longitude -117.37212
Location Coordinate System WGS84
Site Elevation (masl) 555

Parameter

Water Temperature
Field Value
Parameter Water Temperature
Time Zone PT
Unit of Measurement degrees Celsius
Instrument Type Other
Other Unavailable
Instrument Manufacturer Unavailable
Instrument Model Unavailable
Serial Number 1
Instrument Accuracy Unavailable
Range Unavailable
Resolution n/a
Calibration Notes Unavailable
Notes on Method In stream
pH
Field Value
Parameter pH
Time Zone PT
Unit of Measurement pH units
Instrument Type N/A
Instrument Manufacturer Oaktron
Instrument Model pH 200
Serial Number 1
Instrument Accuracy ±0.01 pH
Range 0.00 to 14.00 pH
Resolution n/a
Calibration Notes Calibrated before each use
Notes on Method bottle dip
specific conductivity
Field Value
Parameter specific conductivity
Time Zone PT
Unit of Measurement micromhos per centimetre
Instrument Type N/A
Instrument Manufacturer AMRE
Instrument Model 2300
Serial Number 1
Instrument Accuracy Unavailable
Range Unavailable
Resolution n/a
Calibration Notes Conductivity Bridge calibrated annually using standard solution
Notes on Method bottle dip
turbidity
Field Value
Parameter turbidity
Time Zone PT
Unit of Measurement NTU
Instrument Type N/A
Instrument Manufacturer Hach
Instrument Model 2100Q
Serial Number 1
Instrument Accuracy ± 2 % of reading plus stray light
Range 0-1000
Resolution n/a
Calibration Notes Calibrated before each use
Notes on Method bottle dip
conductivity
Field Value
Parameter conductivity
Time Zone PT
Unit of Measurement microSiemens per centimetre
Instrument Type N/A
Instrument Manufacturer unavailable
Instrument Model unavailable
Serial Number 1
Instrument Accuracy unavailable
Range unavailable
Resolution N/A
Calibration Notes Calibrated before each use
Notes on Method bottle dip
temperature at analysis
Field Value
Parameter temperature at analysis
Time Zone PT
Unit of Measurement degrees Celsius
Instrument Type Other
Other Unavailable
Instrument Manufacturer Unavailable
Instrument Model Unavailable
Serial Number 1
Instrument Accuracy Unavailable
Range Unavailable
Resolution N/A
Calibration Notes Calibrated before each use
Notes on Method bottle dip