Resource metadata

Field Value
Data last updated December 14, 2023
Metadata last updated February 10, 2024
Created March 27, 2023
Format CSV
License CC-BY-SA-4.0
Data collection infoEKISC follows the British Columbia Dreissenid Mussel Lake Monitoring Field Protocol which is updated annually and provided by the Ministry of Environment. The protocol sets provincial standards for plankton tow sample collection, preservation, ancillary data collection, and shipment of samples.
Data processingThe Water Hub has performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data typenon-lab
Datastore activeTrue
Datastore statuspending
Has viewsTrue
Hash680dc75a8e2871ae9b1f78f93ddcca62
Header row1
Id1e13212e-8704-4bc0-8dfd-f4802433319a
Load statusTable was successfully loaded: 4 rows
Mimetypetext/csv
On same domainTrue
Package id13023759-a928-458a-88c6-1e42dea21095
Parameter[{'accuracy': '±0.5°C', 'calibration': 'Not specified', 'instrument_manufacturer': 'Hanna', 'instrument_model': 'HI98127', 'instrument_type': 'Other', 'instrument_type_other': 'pH Pen', 'notes_method': 'As per British Columbia Dreissenid Mussel Lake Monitoring Field Protocol', 'parameter': 'Water Temperature', 'parameter_unit': 'degrees celsius', 'range': '-5.0 to 60.0°C', 'resolution': '0.1°C', 'serial_number': 1, 'time_zone': 'MT'}, {'accuracy': '±0.1 pH', 'calibration': 'Not specified', 'instrument_manufacturer': 'Hanna', 'instrument_model': 'HI98127', 'instrument_type': 'Other', 'instrument_type_other': 'pH Pen', 'notes_method': 'As per British Columbia Dreissenid Mussel Lake Monitoring Field Protocol', 'parameter': 'pH', 'parameter_unit': 'ph units', 'range': '-2.0 to 16.0 pH', 'resolution': '0.1 pH', 'serial_number': 1, 'time_zone': 'MT'}, {'accuracy': 'N/A', 'calibration': 'N/A', 'instrument_manufacturer': 'Not specified', 'instrument_model': 'N/A', 'instrument_type': 'Secchi Disk', 'notes_method': 'As per British Columbia Dreissenid Mussel Lake Monitoring Field Protocol', 'parameter': 'water_clarity_secchi', 'parameter_unit': 'metres', 'range': 'N/A', 'resolution': 'N/A', 'time_zone': 'MT'}]
Recent qa date2023-12-14
Resource citationEast Kootenay Invasive Species Council. (2023). Field Water Quality (2022-06-02 to 2023-09-12) Enid Lake [Resource]. Columbia Basin Water Hub. https://doi.org/10.48511/BJHP-8X25
Resource data disclaimerNo warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose. It was not specified if instruments were calibrated.
Resource locationMeasurements taken at boat launch on Enid Lake.
Site[{'datum': 'WGS84', 'elevation': 1, 'latitude': 50.54664, 'longitude': -116.12301, 'site_id': 'boat_launch_1', 'site_name': 'Boat Launch', 'waterbody': 'Enid Lake', 'waterbody_type': 'lake'}]
Size1.2 KiB
Stateactive
Url typeupload
Waterhub gradeCommunity Research Grade
upload
Citation (Required) East Kootenay Invasive Species Council. (2023). Field Water Quality (2022-06-02 to 2023-09-12) Enid Lake [Resource]. Columbia Basin Water Hub. https://doi.org/10.48511/BJHP-8X25
Resource Location Measurements taken at boat launch on Enid Lake.
Data Collection Information EKISC follows the British Columbia Dreissenid Mussel Lake Monitoring Field Protocol which is updated annually and provided by the Ministry of Environment. The protocol sets provincial standards for plankton tow sample collection, preservation, ancillary data collection, and shipment of samples.
Data Processing The Water Hub has performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data Disclaimer No warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose. It was not specified if instruments were calibrated.
Water Hub Data Grade Community Research Grade
Date of Most Recent Water Hub QA/QC 2023-12-14
Loading Status Table was successfully loaded: 4 rows
Datastore Status pending
Data type General

Data Dictionary

Column Type Label Description BODC ID
date_time text
site_id text
site_latitude text
site_longitude text
notes text
water_temperature text
water_temperature_units text
pH text PHXXPR01 pH per unit volume of the water body by pH electrode SDN:P01::PHXXPR01
pH_units text
water_clarity_secchi text Secchi Estimate of the transparency of the surface water based upon the distance below the ship at which a standard black and white disk becomes visible. SDN:P01::SECCSDNX
water_clarity_secchi_units text
water_hub_qa_qc text

Site

boat_launch_1
Field Value
Site ID boat_launch_1
Site Name Boat Launch
Waterbody Type Lake
Waterbody Enid Lake
Site Latitude 50.54664
Site Longitude -116.12301
Location Coordinate System WGS84
Site Elevation (masl) 1

Parameter

Water Temperature
Field Value
Parameter Water Temperature
Time Zone MT
Unit of Measurement degrees Celsius
Instrument Type Other
Other pH Pen
Instrument Manufacturer Hanna
Instrument Model HI98127
Serial Number 1
Instrument Accuracy ±0.5°C
Range -5.0 to 60.0°C
Resolution 0.1°C
Calibration Notes Not specified
Notes on Method As per British Columbia Dreissenid Mussel Lake Monitoring Field Protocol
pH
Field Value
Parameter pH
Time Zone MT
Unit of Measurement pH units
Instrument Type Other
Other pH Pen
Instrument Manufacturer Hanna
Instrument Model HI98127
Serial Number 1
Instrument Accuracy ±0.1 pH
Range -2.0 to 16.0 pH
Resolution 0.1 pH
Calibration Notes Not specified
Notes on Method As per British Columbia Dreissenid Mussel Lake Monitoring Field Protocol
water_clarity_secchi
Field Value
Parameter water_clarity_secchi
Time Zone MT
Unit of Measurement metres
Instrument Type Secchi Disk
Instrument Manufacturer Not specified
Instrument Model N/A
Instrument Accuracy N/A
Range N/A
Resolution N/A
Calibration Notes N/A
Notes on Method As per British Columbia Dreissenid Mussel Lake Monitoring Field Protocol