Resource metadata

Field Value
Data last updated December 6, 2023
Metadata last updated February 10, 2024
Created December 4, 2021
Format CSV
License CC-BY-SA-4.0
Data collection infoThe temperature loggers were deployed at the same locations for several years. They were installed fastened to a cable that was wrapped around a boulder or tree adjacent to the river.
Data processingParameters with unacceptably high or low readings were removed by SWSS. These readings were likely due to the logger being swept out of the water during freshet or major weather events. The Water Hub has also performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data typenon-lab
Datastore activeTrue
Datastore statuspending
Has viewsTrue
Hash7ca232950569f5c5191277b092353a1a
Header row1
Idce7f6bb3-f7c1-4d55-9ee3-4380a88c9ceb
Load statusTable was successfully loaded: 52960 rows
Mimetypetext/csv
On same domainTrue
Package idfe9cc015-ccd6-4775-b4e1-2633064cb37d
Parameter[{'accuracy': '±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F)', 'calibration': 'Calibration is completed at each readout event. The logger is removed from metal housing tube and connected to HOBO Shuttle where the data is transfered. The shuttle is then offloaded onto the computer for analysis. The is completed roughly once each year. During read out the loggers are checked for any damage to the logger/housing and battery status. Loggers with low battery life and/or damage are replaced.', 'instrument_manufacturer': 'HOBO', 'instrument_model': 'Pro V2', 'instrument_type': 'Data Logger', 'notes_method': 'Temperature Loggers are housed in a metal tube that is attached to a cable fastened to a tree or rock on shore. Cable lenghts range from 2 to 4 meters. The logger/housing is placed in a deep pool and pinched between rocks to secure them during freshet.', 'parameter': 'Water Temperature', 'parameter_unit': 'degrees celsius', 'range': '-40° to 70°C (-40° to 158°F) in air; maximum sustained temperature of 50°C (122°F) in water', 'resolution': '0.02°C at 25°C (0.04°F at 77°F)', 'time_zone': 'PST'}]
Resource citationSalmo Watershed Streamkeepers Society. (2021). Temperature (2014-08-02 to 2020-08-17) Erie Creek (Upper). Columbia Basin Water Hub [Resource]. Salmo. https://doi.org/10.48511/wp6d-bg88
Resource data disclaimerNo warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Resource locationErie Creek Upper is located ~30m downstream from bridge at Erie Forest Service Rec Site on river right.
Site[{'datum': 'WGS84', 'latitude': 49.0259979, 'longitude': -117.389316, 'site_id': 'erie_upper', 'site_name': 'erie_upper', 'waterbody': 'Samo River', 'waterbody_type': 'stream/river'}]
Size5 MiB
Stateactive
Url typeupload
Waterhub gradeCommunity Research Grade
upload
Citation (Required) Salmo Watershed Streamkeepers Society. (2021). Temperature (2014-08-02 to 2020-08-17) Erie Creek (Upper). Columbia Basin Water Hub [Resource]. Salmo. https://doi.org/10.48511/wp6d-bg88
Resource Location Erie Creek Upper is located ~30m downstream from bridge at Erie Forest Service Rec Site on river right.
Data Collection Information The temperature loggers were deployed at the same locations for several years. They were installed fastened to a cable that was wrapped around a boulder or tree adjacent to the river.
Data Processing Parameters with unacceptably high or low readings were removed by SWSS. These readings were likely due to the logger being swept out of the water during freshet or major weather events. The Water Hub has also performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data Disclaimer No warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Water Hub Data Grade Community Research Grade
Date of Most Recent Water Hub QA/QC
Loading Status Table was successfully loaded: 52960 rows
Datastore Status pending
Data type General

Data Dictionary

Column Type Label Description BODC ID
date_time timestamp
site_id text
latitude float8
longitude float8
notes float8
water_temperature float8
water_temperature_units text
water_hub_qa_qc text

Site

erie_upper
Field Value
Site ID erie_upper
Site Name erie_upper
Waterbody Type Stream/River
Waterbody Samo River
Site Latitude 49.0259979
Site Longitude -117.389316
Location Coordinate System WGS84
Site Elevation (masl)

Parameter

Water Temperature
Field Value
Parameter Water Temperature
Time Zone PST
Unit of Measurement degrees Celsius
Instrument Type Data Logger
Instrument Manufacturer HOBO
Instrument Model Pro V2
Instrument Accuracy ±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F)
Range -40° to 70°C (-40° to 158°F) in air; maximum sustained temperature of 50°C (122°F) in water
Resolution 0.02°C at 25°C (0.04°F at 77°F)
Calibration Notes Calibration is completed at each readout event. The logger is removed from metal housing tube and connected to HOBO Shuttle where the data is transfered. The shuttle is then offloaded onto the computer for analysis. The is completed roughly once each year. During read out the loggers are checked for any damage to the logger/housing and battery status. Loggers with low battery life and/or damage are replaced.
Notes on Method Temperature Loggers are housed in a metal tube that is attached to a cable fastened to a tree or rock on shore. Cable lenghts range from 2 to 4 meters. The logger/housing is placed in a deep pool and pinched between rocks to secure them during freshet.