Temperature (2022-10-19 to 2023-07-13) Elk River (ELK002)
Download: era_temp_elk002_20221019-20230713.csv
This resource is part of the Elk River Alliance's Hydrometric Monitoring Program and contains temperature measurements at site ELK002 on the Elk River.
Resource metadata
Field | Value |
Data last updated | January 17, 2024 |
Metadata last updated | January 17, 2024 |
Created | January 17, 2024 |
Format | CSV |
License | CC-BY-NC-SA-4.0 |
Data collection info | The Hobo MX2203 temperature logger was deployed along the Elk River at site ELK002 on October 19, 2022. Measurements of temperature were taken at 1 hour intervals. |
Data processing | The Water Hub has completed a preliminary QA/QC protocol on this file, however the individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose. |
Data type | non-lab |
Datastore status | pending |
Has views | True |
Hash | 817d03d684ad711fe1cdb7fcedc0bf4c |
Header row | 1 |
Id | 64ecdf72-91e6-4e0f-b7d8-8313a52057ae |
Load status | Reading tabular file era_temp_elk002_20221019-20230713.csv (csv) |
Mimetype | text/csv |
Package id | fcd82cb5-696b-436e-85bb-2948249498f8 |
Parameter | [{'accuracy': '± 0.2°C', 'calibration': 'Factory calibrated', 'instrument_manufacturer': 'Onset', 'instrument_model': 'Hobo MX2203', 'instrument_type': 'Data Logger', 'notes_method': '', 'parameter': 'Water Temperature', 'parameter_unit': 'degrees celsius', 'range': '-20°C - 50°C (in water)', 'resolution': '0.01°C', 'serial_number': '21306956', 'time_zone': 'GMT-7'}] |
Position | 2 |
Resource citation | Elk River Watershed Alliance. (2023). Temperature (2022-10-19 to 2023-07-13) Elk River (ELK002)[Resource]. Columbia Basin Water Hub. DOI |
Resource data disclaimer | No warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose. |
Resource location | Elk River, Elk River Watershed |
Site | [{'datum': 'NAD83', 'elevation': 1684, 'latitude': 50.5152762, 'longitude': -114.998874, 'site_id': 'ELK002', 'site_name': 'Elk River', 'waterbody': 'Elk River', 'waterbody_type': 'stream/river'}] |
Size | 542 KiB |
State | active |
Url type | upload |
Waterhub grade | Technical Research Grade |
upload | |
Citation (Required) | Elk River Watershed Alliance. (2023). Temperature (2022-10-19 to 2023-07-13) Elk River (ELK002)[Resource]. Columbia Basin Water Hub. DOI |
Resource Location | Elk River, Elk River Watershed |
Data Collection Information | The Hobo MX2203 temperature logger was deployed along the Elk River at site ELK002 on October 19, 2022. Measurements of temperature were taken at 1 hour intervals. |
Data Processing | The Water Hub has completed a preliminary QA/QC protocol on this file, however the individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose. |
Data Disclaimer | No warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose. |
Water Hub Data Grade | Technical Research Grade |
Date of Most Recent Water Hub QA/QC | |
Loading Status | Reading tabular file era_temp_elk002_20221019-20230713.csv (csv) |
Datastore Status | pending |
Data type | General |
Site
Field | Value |
Site ID | ELK002 |
Site Name | Elk River |
Waterbody Type | Stream/River |
Waterbody | Elk River |
Site Latitude | 50.5152762 |
Site Longitude | -114.998874 |
Location Coordinate System | NAD83 |
Site Elevation (masl) | 1684 |
Parameter
Field | Value |
Parameter | Water Temperature |
Time Zone | GMT-7 |
Unit of Measurement | degrees Celsius |
Instrument Type | Data Logger |
Instrument Manufacturer | Onset |
Instrument Model | Hobo MX2203 |
Serial Number | 21306956 |
Instrument Accuracy | ± 0.2°C |
Range | -20°C - 50°C (in water) |
Resolution | 0.01°C |
Calibration Notes | Factory calibrated |