Resource metadata

Field Value
Data last updated November 12, 2024
Metadata last updated November 12, 2024
Created August 22, 2023
Format CSV
License CC-BY-NC-SA-4.0
Ckan urlhttps://data.cbwaterhub.ca
Data collection infoData is collected from hydrometric stations that measure water level (stage). For stream sites, this measured water level is used to calculate discharge (the volume of water flowing past at a particular time). Water temperature is also collected at these permanent hydrometric stations.
Data processingReal time water stage data is subject to preliminary correction to compensate for manual stage measurements, as well as potential instrument drift. Stage data that appears suspect or is impacted by ice within the winter is also removed. Data is finalized once a year, at which time corrections are confirmed and additional corrections (such as data filling and smoothing) may be applied.
Data typenon-lab
Datastore activeTrue
Datastore contains all records of source fileTrue
Datastore statuspending
Has viewsTrue
Hash0df77e1b67e6fa8d3be18e600fa70233
Header row1
Id0a3f915c-dcf0-4b9d-91e5-ac76f9dda3e4
Ignore hashFalse
Load statusTable was successfully loaded: 77118 rows
Mimetypetext/csv
Original urlhttps://data.cbwaterhub.ca/dataset/4c30f2c5-e145-4a5b-89a3-7120cf605bc2/resource/0a3f915c-dcf0-4b9d-91e5-ac76f9dda3e4/download/llc_hydrometric_glaciercreekupper_mckgla01h_20221002_20240513.csv
Package id4c30f2c5-e145-4a5b-89a3-7120cf605bc2
Parameter[{'accuracy': '± 0.05ºC', 'calibration': 'As per instructed', 'instrument_manufacturer': 'Solinist', 'instrument_model': 'Level Logger', 'instrument_type': 'Data Logger', 'notes_method': 'Corrected', 'parameter': 'Water Temperature', 'parameter_unit': 'degrees celsius', 'range': "'-20ºC to 80ºC", 'resolution': '0.003°C', 'serial_number': '214530', 'time_zone': 'PT'}, {'accuracy': '± 0.05% FS (Barologger 5: ± 0.05 kPa)', 'calibration': 'As per instructed', 'instrument_manufacturer': 'Solinist', 'instrument_model': 'Level Logger', 'instrument_type': 'Data Logger', 'notes_method': 'N/A', 'parameter': 'water_level', 'parameter_unit': 'metres', 'range': '0º to 50ºC (Barologger 5: -10 to +50ºC)', 'resolution': '0.002% FS to 0.0006% FS', 'serial_number': '214530', 'time_zone': 'PT'}, {'accuracy': '± 0.05% FS (Barologger 5: ± 0.05 kPa)', 'calibration': 'As per instructed', 'instrument_manufacturer': 'Solinist', 'instrument_model': 'Level Logger', 'instrument_type': 'Data Logger', 'notes_method': 'N/A', 'parameter': 'Discharge', 'parameter_unit': 'metres3 per second', 'range': '0º to 50ºC (Barologger 5: -10 to +50ºC)', 'resolution': '0.002% FS to 0.0006% FS', 'serial_number': '214530', 'time_zone': 'PT'}]
Position0
Recent qa date2023-08-22
Resource citationLiving Lakes Canada. (2023). Preliminary Hydrometric (2022-10-02 to 2024-05-13) Upper Glacier Creek [Resource]. Columbia Basin Water Hub.
Resource data disclaimerThe data presented herein is of a preliminary nature and should be treated as such. The preliminary nature of the data implies that it is subject to revision, verification, and validation. Users are advised to exercise caution and independently verify the accuracy and reliability of the data before making any decisions or drawing conclusions based on it. Living Lakes Canada is responsible for providing the preliminary data and disclaims any warranty or guarantee, express or implied, regarding its accuracy, completeness, or suitability for any particular purpose. Living Lakes Canada carries no liability and use of the preliminary data is solely at the user's own risk, and the organization shall not be held liable for any damages or losses resulting from its use. Your proceeding beyond this Disclaimer will constitute your acceptance of the terms and conditions outlined above.
Resource id0a3f915c-dcf0-4b9d-91e5-ac76f9dda3e4
Resource locationMonitoring station is located in the upper reaches of Glacier Creek approximately 17km east of Duncan Lake.
Set url typeFalse
Site[{'datum': 'Not specified', 'elevation': 630, 'latitude': 49.94502, 'longitude': -117.32282, 'site_id': 'MCKGLA01H', 'site_name': 'Upper Glacier Creek', 'waterbody': 'Upper Glacier Creek', 'waterbody_type': 'stream/river'}]
Size20.1 MiB
Stateactive
Task created2024-11-12 16:09:01.132562
Url typeupload
Waterhub gradeTechnical Research Grade
Citation (Required) Living Lakes Canada. (2023). Preliminary Hydrometric (2022-10-02 to 2024-05-13) Upper Glacier Creek [Resource]. Columbia Basin Water Hub.
Resource Location Monitoring station is located in the upper reaches of Glacier Creek approximately 17km east of Duncan Lake.
Data Collection Information Data is collected from hydrometric stations that measure water level (stage). For stream sites, this measured water level is used to calculate discharge (the volume of water flowing past at a particular time). Water temperature is also collected at these permanent hydrometric stations.
Data Processing Real time water stage data is subject to preliminary correction to compensate for manual stage measurements, as well as potential instrument drift. Stage data that appears suspect or is impacted by ice within the winter is also removed. Data is finalized once a year, at which time corrections are confirmed and additional corrections (such as data filling and smoothing) may be applied.
Data Disclaimer The data presented herein is of a preliminary nature and should be treated as such. The preliminary nature of the data implies that it is subject to revision, verification, and validation. Users are advised to exercise caution and independently verify the accuracy and reliability of the data before making any decisions or drawing conclusions based on it. Living Lakes Canada is responsible for providing the preliminary data and disclaims any warranty or guarantee, express or implied, regarding its accuracy, completeness, or suitability for any particular purpose. Living Lakes Canada carries no liability and use of the preliminary data is solely at the user's own risk, and the organization shall not be held liable for any damages or losses resulting from its use. Your proceeding beyond this Disclaimer will constitute your acceptance of the terms and conditions outlined above.
Water Hub Data Grade Technical Research Grade
Date of Most Recent Water Hub QA/QC 2023-08-22
Loading Status Table was successfully loaded: 77118 rows
Datastore Status pending
Data type General

Data Dictionary

Column Type Label Description BODC ID
date_time text
site_id text
latitude text
longitude text
notes text
water_temperature text
water_temperature_units text
water_level text DepBelowSurf The distance of a sensor or sampling point below the sea surface SDN:P01::ADEPZZ01
water_level_units text
discharge text
discharge_units text
water_hub_qa_qc text

Site

MCKGLA01H
Field Value
Site ID MCKGLA01H
Site Name Upper Glacier Creek
Waterbody Type Stream/River
Waterbody Upper Glacier Creek
Site Latitude 49.94502
Site Longitude -117.32282
Location Coordinate System Not specified
Site Elevation (masl) 630

Parameter

Water Temperature
Field Value
Parameter Water Temperature
Time Zone PT
Unit of Measurement degrees Celsius
Instrument Type Data Logger
Instrument Manufacturer Solinist
Instrument Model Level Logger
Serial Number 214530
Instrument Accuracy ± 0.05ºC
Range '-20ºC to 80ºC
Resolution 0.003°C
Calibration Notes As per instructed
Notes on Method Corrected
water_level
Field Value
Parameter water_level
Time Zone PT
Unit of Measurement metres
Instrument Type Data Logger
Instrument Manufacturer Solinist
Instrument Model Level Logger
Serial Number 214530
Instrument Accuracy ± 0.05% FS (Barologger 5: ± 0.05 kPa)
Range 0º to 50ºC (Barologger 5: -10 to +50ºC)
Resolution 0.002% FS to 0.0006% FS
Calibration Notes As per instructed
Notes on Method N/A
Discharge
Field Value
Parameter Discharge
Time Zone PT
Unit of Measurement metres3 per second
Instrument Type Data Logger
Instrument Manufacturer Solinist
Instrument Model Level Logger
Serial Number 214530
Instrument Accuracy ± 0.05% FS (Barologger 5: ± 0.05 kPa)
Range 0º to 50ºC (Barologger 5: -10 to +50ºC)
Resolution 0.002% FS to 0.0006% FS
Calibration Notes As per instructed
Notes on Method N/A