Resource metadata

Field Value
Data last updated January 14, 2025
Metadata last updated January 15, 2025
Created June 15, 2021
Format CSV
License CC-BY-SA-4.0
Data collection infoThe sampling team located the site each week by GPS, then dropped anchor to minimise drift, before taking water samples at a depth of 1m.
Data processingThe Water Hub has performed a preliminary QA/QC protocol on this data and flagged several unexpected values, but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data typenon-lab
Datastore activeTrue
Datastore contains all records of source fileFalse
Datastore statuspending
Has viewsTrue
Hashdda9024bee8fb3fa0489152697345019
Header row1
Id48e67830-020c-4909-b824-8c18a12fcfd3
Load statusTable was successfully loaded: 560 rows
Mimetypetext/csv
Package id37862d14-650c-4845-9559-52010d85138b
Parameter[{'accuracy': '±0.2 °C', 'calibration': 'Calibrated monthly, log available on request', 'instrument_manufacturer': 'YSI', 'instrument_model': 'Pro 30', 'instrument_type': 'Portable Multiparameter Meter', 'notes_method': 'Current as of September 2020', 'parameter': 'Water Temperature', 'parameter_unit': 'degrees celsius', 'range': '-5 to 55 °C', 'resolution': 'N/A', 'serial_number': '20A100281', 'time_zone': 'MST'}, {'accuracy': '±0.1', 'calibration': 'Calibrated monthly, log available on request', 'instrument_manufacturer': 'Eutech', 'instrument_model': 'pHTestr 10', 'instrument_type': 'Portable Meter', 'notes_method': 'Current as of September 2020', 'parameter': 'pH', 'parameter_unit': 'ph units', 'range': '-1.0 to 15.0', 'resolution': 'N/A', 'serial_number': '960762', 'time_zone': 'MDT'}, {'accuracy': 'N/A', 'calibration': 'N/A', 'instrument_manufacturer': 'N/A', 'instrument_model': 'N/A', 'instrument_type': 'N/A', 'notes_method': 'Current as of September 2020', 'parameter': 'odour', 'parameter_unit': 'observation', 'range': 'N/A', 'resolution': 'N/A', 'serial_number': 'N/A', 'time_zone': 'N/A'}, {'accuracy': 'N/A', 'calibration': 'N/A', 'instrument_manufacturer': 'N/A', 'instrument_model': 'N/A', 'instrument_type': 'N/A', 'notes_method': 'Current as of September 2020', 'parameter': 'Wind Speed', 'parameter_unit': 'kilometres per hour', 'range': 'N/A', 'resolution': 'N/A', 'serial_number': 'N/A', 'time_zone': 'N/A'}, {'accuracy': 'N/A', 'calibration': 'N/A', 'instrument_manufacturer': 'N/A', 'instrument_model': 'N/A', 'instrument_type': 'N/A', 'notes_method': 'Current as of September 2020', 'parameter': 'Water Colour', 'parameter_unit': 'observation', 'range': 'N/A', 'resolution': 'N/A', 'serial_number': 'N/A', 'time_zone': 'N/A'}, {'accuracy': '0-1000 NTU', 'calibration': 'Calibrated monthly, log available on request', 'instrument_manufacturer': 'Hach', 'instrument_model': '2100Q', 'instrument_type': 'Portable Meter', 'notes_method': 'Current as of September 2020', 'parameter': 'turbidity', 'parameter_unit': 'ntu', 'range': '±2% plus stray light', 'resolution': 'N/A', 'serial_number': '12120C021971', 'time_zone': 'MDT'}, {'accuracy': 'N/A', 'calibration': 'Calibrated monthly, log available on request', 'instrument_manufacturer': 'YSI', 'instrument_model': 'Pro 30', 'instrument_type': 'Portable Multiparameter Meter', 'notes_method': 'For 2019 and prior, DO was measured using the Winkler Titration Method and a Hach Model OX-2P (0.2-20mg/L) Test Kit. Current as of September 2020.', 'parameter': 'dissolved oxygen', 'parameter_unit': 'milligrams per litre', 'range': 'N/A', 'resolution': 'N/A', 'serial_number': '20A100281', 'time_zone': 'MDT'}, {'accuracy': 'N/A', 'calibration': 'Calibrated monthly, log available on request', 'instrument_manufacturer': 'YSI', 'instrument_model': 'Pro 30', 'instrument_type': 'Portable Multiparameter Meter', 'notes_method': 'Current as of September 2020', 'parameter': 'specific conductivity', 'parameter_unit': 'microsiemens per centimetre', 'range': '0 to 200 mS/cm (auto-range)', 'resolution': '0.0001 to 0.1 mS/cm (range dependent)', 'serial_number': '20A100281', 'time_zone': 'MDT'}, {'accuracy': '±0.1 m', 'calibration': 'N/A', 'instrument_manufacturer': 'N/A', 'instrument_model': 'N/A', 'instrument_type': 'Secchi Disk', 'notes_method': 'Current as of September 2020', 'parameter': 'depth', 'parameter_unit': 'standard atmosphere (atm)', 'range': 'N/A', 'resolution': 'N/A', 'serial_number': 'N/A', 'time_zone': 'MDT'}, {'accuracy': '±0.25 m', 'calibration': 'N/A', 'instrument_manufacturer': 'N/A', 'instrument_model': 'N/A', 'instrument_type': 'Secchi Disk', 'notes_method': 'Depth and Secchi depth measurements were taken using a weighted Secchi disk and meter line. Current as of September 2020.', 'parameter': 'Clarity', 'parameter_unit': 'metres', 'range': 'N/A', 'resolution': 'N/A', 'serial_number': 'N/A', 'time_zone': 'MDT'}, {'accuracy': '±1 °C', 'calibration': 'Instruments are calibrated monthly, a calibration log is available.', 'instrument_manufacturer': 'H-B USA', 'instrument_model': 'N/A', 'instrument_type': 'Analog Thermometer', 'notes_method': 'Current as of September 2020', 'parameter': 'Air temperature', 'parameter_unit': 'degrees celsius', 'range': 'N/A', 'resolution': 'N/A', 'serial_number': 'N/A', 'time_zone': 'MDT'}, {'accuracy': 'N/A', 'calibration': 'N/A', 'instrument_manufacturer': 'N/A', 'instrument_model': 'N/A', 'instrument_type': 'N/A', 'notes_method': 'Current as of September 2020', 'parameter': 'Surface Water Conditions and Observations', 'parameter_unit': 'observation', 'range': 'N/A', 'resolution': 'N/A', 'serial_number': 'N/A', 'time_zone': 'N/A'}, {'accuracy': 'N/A', 'calibration': 'N/A', 'instrument_manufacturer': 'N/A', 'instrument_model': 'N/A', 'instrument_type': 'Observation', 'notes_method': 'Current as of September 2020', 'parameter': 'cloud cover', 'parameter_unit': 'percent', 'range': 'N/A', 'resolution': 'N/A', 'serial_number': 'N/A', 'time_zone': 'N/A'}]
Position0
Recent qa date2025-01-14
Resource citationLake Windermere Ambassadors (2022). Weekly Water Monitoring (2011-06-06 to 2024-09-10) Lake Windermere (North Upper - LWNU, North Lower - LWNL, Mid - LWMU and LWSU)[Resource]. Columbia Basin Water Hub. https://doi.org/10.48511/sw3k-fv60
Resource data disclaimerNo warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Resource locationNorth Upper - LWNU, North Lower - LWNL, Mid - LWMU and South - LWSU
Site[{'datum': 'NAD83', 'elevation': 798, 'latitude': 50.46017, 'longitude': -115.99777, 'site_id': 'LWMU', 'site_name': 'Lake Windermere Mid', 'waterbody': 'Lake Windermere', 'waterbody_type': 'lake'}, {'datum': 'NAD83', 'elevation': 798, 'latitude': 50.4938, 'longitude': -116.01638, 'site_id': 'LWNU', 'site_name': 'Lake Windermere North Upper', 'waterbody': 'Lake Windermere', 'waterbody_type': 'lake'}, {'datum': 'NAD83', 'elevation': 798, 'latitude': 50.4938, 'longitude': -116.01638, 'site_id': 'LWNL', 'site_name': 'Lake Windermere North Lower', 'waterbody': 'Lake Windermere', 'waterbody_type': 'lake'}, {'datum': 'NAD83', 'elevation': 798, 'latitude': 50.41659, 'longitude': -115.94283, 'site_id': 'LWSU', 'site_name': 'Lake Windermere South', 'waterbody': 'Lake Windermere', 'waterbody_type': 'lake'}]
Size172.2 KiB
Stateactive
Url typeupload
Waterhub gradeTechnical Research Grade
Citation (Required) Lake Windermere Ambassadors (2022). Weekly Water Monitoring (2011-06-06 to 2024-09-10) Lake Windermere (North Upper - LWNU, North Lower - LWNL, Mid - LWMU and LWSU)[Resource]. Columbia Basin Water Hub. https://doi.org/10.48511/sw3k-fv60
Resource Location North Upper - LWNU, North Lower - LWNL, Mid - LWMU and South - LWSU
Data Collection Information The sampling team located the site each week by GPS, then dropped anchor to minimise drift, before taking water samples at a depth of 1m.
Data Processing The Water Hub has performed a preliminary QA/QC protocol on this data and flagged several unexpected values, but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data Disclaimer No warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Water Hub Data Grade Technical Research Grade
Date of Most Recent Water Hub QA/QC 2025-01-14
Loading Status Table was successfully loaded: 560 rows
Datastore Status pending
Data type General

Data Dictionary

Column Type Label Description BODC ID
date_time timestamp
site_id text
latitude float8
longitude float8
notes text
water_temperature text
water_temperature_units text
pH float8
pH_units text
turbidity float8
turbidity_units text
dissolved_oxygen text
dissolved_oxygen_units text
specific_conductivity float8
specific_conductivity_units text
water_depth text
water_depth_units text
water_clarity_secchi float8
water_clarity_secchi_units text
air_temperature float8
air_temperature_units text
surface_conditions text
surface_conditions_units text
cloud_cover text
cloud_cover_units text
water_odour text
water_odour_units text
wind_speed text
wind_speed_units text
water_colour text
water_colour_units text
water_hub_qa_qc text

Site

LWMU
Field Value
Site ID LWMU
Site Name Lake Windermere Mid
Waterbody Type Lake
Waterbody Lake Windermere
Site Latitude 50.46017
Site Longitude -115.99777
Location Coordinate System NAD83
Site Elevation (masl) 798
LWNU
Field Value
Site ID LWNU
Site Name Lake Windermere North Upper
Waterbody Type Lake
Waterbody Lake Windermere
Site Latitude 50.4938
Site Longitude -116.01638
Location Coordinate System NAD83
Site Elevation (masl) 798
LWNL
Field Value
Site ID LWNL
Site Name Lake Windermere North Lower
Waterbody Type Lake
Waterbody Lake Windermere
Site Latitude 50.4938
Site Longitude -116.01638
Location Coordinate System NAD83
Site Elevation (masl) 798
LWSU
Field Value
Site ID LWSU
Site Name Lake Windermere South
Waterbody Type Lake
Waterbody Lake Windermere
Site Latitude 50.41659
Site Longitude -115.94283
Location Coordinate System NAD83
Site Elevation (masl) 798

Parameter

Water Temperature
Field Value
Parameter Water Temperature
Time Zone MST
Unit of Measurement degrees Celsius
Instrument Type Portable Multiparameter Meter
Instrument Manufacturer YSI
Instrument Model Pro 30
Serial Number 20A100281
Instrument Accuracy ±0.2 °C
Range -5 to 55 °C
Resolution N/A
Calibration Notes Calibrated monthly, log available on request
Notes on Method Current as of September 2020
pH
Field Value
Parameter pH
Time Zone MDT
Unit of Measurement pH units
Instrument Type Portable Meter
Instrument Manufacturer Eutech
Instrument Model pHTestr 10
Serial Number 960762
Instrument Accuracy ±0.1
Range -1.0 to 15.0
Resolution N/A
Calibration Notes Calibrated monthly, log available on request
Notes on Method Current as of September 2020
odour
Field Value
Parameter odour
Time Zone N/A
Unit of Measurement observation
Instrument Type N/A
Instrument Manufacturer N/A
Instrument Model N/A
Serial Number N/A
Instrument Accuracy N/A
Range N/A
Resolution N/A
Calibration Notes N/A
Notes on Method Current as of September 2020
Wind Speed
Field Value
Parameter Wind Speed
Time Zone N/A
Unit of Measurement kilometres per hour
Instrument Type N/A
Instrument Manufacturer N/A
Instrument Model N/A
Serial Number N/A
Instrument Accuracy N/A
Range N/A
Resolution N/A
Calibration Notes N/A
Notes on Method Current as of September 2020
Water Colour
Field Value
Parameter Water Colour
Time Zone N/A
Unit of Measurement observation
Instrument Type N/A
Instrument Manufacturer N/A
Instrument Model N/A
Serial Number N/A
Instrument Accuracy N/A
Range N/A
Resolution N/A
Calibration Notes N/A
Notes on Method Current as of September 2020
turbidity
Field Value
Parameter turbidity
Time Zone MDT
Unit of Measurement NTU
Instrument Type Portable Meter
Instrument Manufacturer Hach
Instrument Model 2100Q
Serial Number 12120C021971
Instrument Accuracy 0-1000 NTU
Range ±2% plus stray light
Resolution N/A
Calibration Notes Calibrated monthly, log available on request
Notes on Method Current as of September 2020
dissolved oxygen
Field Value
Parameter dissolved oxygen
Time Zone MDT
Unit of Measurement milligrams per litre
Instrument Type Portable Multiparameter Meter
Instrument Manufacturer YSI
Instrument Model Pro 30
Serial Number 20A100281
Instrument Accuracy N/A
Range N/A
Resolution N/A
Calibration Notes Calibrated monthly, log available on request
Notes on Method For 2019 and prior, DO was measured using the Winkler Titration Method and a Hach Model OX-2P (0.2-20mg/L) Test Kit. Current as of September 2020.
specific conductivity
Field Value
Parameter specific conductivity
Time Zone MDT
Unit of Measurement microSiemens per centimetre
Instrument Type Portable Multiparameter Meter
Instrument Manufacturer YSI
Instrument Model Pro 30
Serial Number 20A100281
Instrument Accuracy N/A
Range 0 to 200 mS/cm (auto-range)
Resolution 0.0001 to 0.1 mS/cm (range dependent)
Calibration Notes Calibrated monthly, log available on request
Notes on Method Current as of September 2020
depth
Field Value
Parameter depth
Time Zone MDT
Unit of Measurement standard atmosphere (atm)
Instrument Type Secchi Disk
Instrument Manufacturer N/A
Instrument Model N/A
Serial Number N/A
Instrument Accuracy ±0.1 m
Range N/A
Resolution N/A
Calibration Notes N/A
Notes on Method Current as of September 2020
Clarity
Field Value
Parameter Clarity
Time Zone MDT
Unit of Measurement metres
Instrument Type Secchi Disk
Instrument Manufacturer N/A
Instrument Model N/A
Serial Number N/A
Instrument Accuracy ±0.25 m
Range N/A
Resolution N/A
Calibration Notes N/A
Notes on Method Depth and Secchi depth measurements were taken using a weighted Secchi disk and meter line. Current as of September 2020.
Air temperature
Field Value
Parameter Air temperature
Time Zone MDT
Unit of Measurement degrees Celsius
Instrument Type Analog Thermometer
Instrument Manufacturer H-B USA
Instrument Model N/A
Serial Number N/A
Instrument Accuracy ±1 °C
Range N/A
Resolution N/A
Calibration Notes Instruments are calibrated monthly, a calibration log is available.
Notes on Method Current as of September 2020
Surface Water Conditions and Observations
Field Value
Parameter Surface Water Conditions and Observations
Time Zone N/A
Unit of Measurement observation
Instrument Type N/A
Instrument Manufacturer N/A
Instrument Model N/A
Serial Number N/A
Instrument Accuracy N/A
Range N/A
Resolution N/A
Calibration Notes N/A
Notes on Method Current as of September 2020
cloud cover
Field Value
Parameter cloud cover
Time Zone N/A
Unit of Measurement percent
Instrument Type Observation
Instrument Manufacturer N/A
Instrument Model N/A
Serial Number N/A
Instrument Accuracy N/A
Range N/A
Resolution N/A
Calibration Notes N/A
Notes on Method Current as of September 2020