Resource metadata

Field Value
Data last updated March 19, 2024
Metadata last updated March 19, 2024
Created March 19, 2024
Format CSV
License CC-BY-SA-4.0
Data collection infoTemperature and pH are measured using a Hanna Industries pen meter (HI98129) within 2-4” of the surface. Secchi depths are collected where there is sufficient depth to measure from the sampling location. Data collection is consistent with the Invasive Mussel Field Protocol prepared by the Ecosystems Branch, BC Ministry of Environment and Climate Change Strategy.
Data processingThe Water Hub has performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data typenon-lab
Datastore activeTrue
Datastore contains all records of source fileFalse
Datastore statuspending
Has viewsTrue
Hashe51563194055c32780003faecc2eddf3
Header row1
Id97b2cbc9-ae8a-4b26-a28f-ade6dcd08d7b
Load statusTable was successfully loaded: 5 rows
Mimetypetext/csv
Package ida8ec74fa-ff45-4af0-9587-77e6795cfd93
Parameter[{'accuracy': '±0.5°C', 'calibration': 'N/A', 'instrument_manufacturer': 'HANNA Instruments', 'instrument_model': 'HI98129', 'instrument_type': 'Portable Multiparameter Meter', 'notes_method': 'Low range combination meter', 'parameter': 'Water Temperature', 'parameter_unit': 'degrees celsius', 'range': '-5.0 to 60.0°C', 'resolution': '0.1°C', 'time_zone': 'MT'}, {'accuracy': '±0.05 pH', 'calibration': 'pH is calibrated weekly', 'instrument_manufacturer': 'HANNA Instruments', 'instrument_model': 'HI98129', 'instrument_type': 'Portable Multiparameter Meter', 'notes_method': 'Low range combination meter', 'parameter': 'pH', 'parameter_unit': 'ph units', 'range': '0.00 to 14.00 pH', 'resolution': '0.01 pH', 'time_zone': 'MT'}, {'accuracy': 'N/A', 'calibration': 'N/A', 'instrument_manufacturer': 'N/A', 'instrument_model': 'N/A', 'instrument_type': 'Secchi Disk', 'notes_method': 'Methodology consistent with Invasive Mussel Field Protocol prepared by the Ecosystems Branch, BC Ministry of Environment and Climate Change Strategy', 'parameter': 'depth', 'parameter_unit': 'metres', 'range': 'N/A', 'resolution': 'N/A', 'time_zone': 'MT'}]
Position0
Recent qa date2024-03-19
Resource citationColumbia Shuswap Invasive Species Society. (2023). Water Quality (2017-07-07 to 2018-10-11) Little Shuswap Lake at Chase Memorial Park. [Resource]. Columbia Basin Water Hub. DOI
Resource data disclaimerNo warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. Instrument accuracy may be limited. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Resource id97b2cbc9-ae8a-4b26-a28f-ade6dcd08d7b
Resource location Little Shuswap Lake at Chase Memorial Park
Site[{'datum': 'WGS84', 'elevation': 755, 'latitude': 50.82804, 'longitude': -119.67768, 'site_id': 'Little Shuswap Lake Chase Memorial Park', 'site_name': 'Little Shuswap Lake Chase Memorial Park', 'waterbody': 'Little Shuswap Lake, Kinbasket Reservoir', 'waterbody_type': 'lake'}]
Size930 bytes
Stateactive
Url typeupload
Waterhub gradeCommunity Research Grade
Citation (Required) Columbia Shuswap Invasive Species Society. (2023). Water Quality (2017-07-07 to 2018-10-11) Little Shuswap Lake at Chase Memorial Park. [Resource]. Columbia Basin Water Hub. DOI
Resource Location Little Shuswap Lake at Chase Memorial Park
Data Collection Information Temperature and pH are measured using a Hanna Industries pen meter (HI98129) within 2-4” of the surface. Secchi depths are collected where there is sufficient depth to measure from the sampling location. Data collection is consistent with the Invasive Mussel Field Protocol prepared by the Ecosystems Branch, BC Ministry of Environment and Climate Change Strategy.
Data Processing The Water Hub has performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data Disclaimer No warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. Instrument accuracy may be limited. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Water Hub Data Grade Community Research Grade
Date of Most Recent Water Hub QA/QC 2024-03-19
Loading Status Table was successfully loaded: 5 rows
Datastore Status pending
Data type General

Data Dictionary

Column Type Label Description BODC ID
date_time text
site_id text
latitude float8
longitude float8
notes text
water_temperature float8
water_temperature_units text
pH float8
pH_units text
depth float8
depth_units text
water_hub_qa_qc float8

Site

Little Shuswap Lake Chase Memorial Park
Field Value
Site ID Little Shuswap Lake Chase Memorial Park
Site Name Little Shuswap Lake Chase Memorial Park
Waterbody Type Lake
Waterbody Little Shuswap Lake, Kinbasket Reservoir
Site Latitude 50.82804
Site Longitude -119.67768
Location Coordinate System WGS84
Site Elevation (masl) 755

Parameter

Water Temperature
Field Value
Parameter Water Temperature
Time Zone MT
Unit of Measurement degrees Celsius
Instrument Type Portable Multiparameter Meter
Instrument Manufacturer HANNA Instruments
Instrument Model HI98129
Instrument Accuracy ±0.5°C
Range -5.0 to 60.0°C
Resolution 0.1°C
Calibration Notes N/A
Notes on Method Low range combination meter
pH
Field Value
Parameter pH
Time Zone MT
Unit of Measurement pH units
Instrument Type Portable Multiparameter Meter
Instrument Manufacturer HANNA Instruments
Instrument Model HI98129
Instrument Accuracy ±0.05 pH
Range 0.00 to 14.00 pH
Resolution 0.01 pH
Calibration Notes pH is calibrated weekly
Notes on Method Low range combination meter
depth
Field Value
Parameter depth
Time Zone MT
Unit of Measurement metres
Instrument Type Secchi Disk
Instrument Manufacturer N/A
Instrument Model N/A
Instrument Accuracy N/A
Range N/A
Resolution N/A
Calibration Notes N/A
Notes on Method Methodology consistent with Invasive Mussel Field Protocol prepared by the Ecosystems Branch, BC Ministry of Environment and Climate Change Strategy