Resource metadata

Field Value
Data last updated October 27, 2021
Metadata last updated October 27, 2021
Created October 27, 2021
Format PDF
License CC-BY-NC-SA-4.0
Data collection infoField methods for sample collection followed those outlined in the BC Field Sampling Manual for Continuous Monitoring and the Collection of Air, Air-Emission, Water, Wastewater, Soil, Sediment, and Biological Samples (BC MOE 2013). Samples were collected into clean, pre-labelled containers provided by ALS Environmental Laboratories. In-situ measurements of dissolved oxygen (DO), temperature, conductivity (including specific conductance), pH, and oxidation-reduction potential (ORP) were taken in the field using a YSI Pro Plus. Field blanks and duplicate samples were used to ensure accuracy and precision of the data. The results of the field blanks were checked for exceedances of the method detection limits (MDL). Blanks that exceed 2 times the MDL are commonly flagged for QA/QC concerns, as recommended by the BC Ministry of Environment (BC MOE 2013).
Data processingOnce collected, samples were stored in the field in a cooler with ice packs and additional ice and ice packs were added to the coolers before samples were shipped to ALS laboratories in Calgary. ALS is an ISO/IEC 17025 accredited full-service laboratory. Parameters analyzed were in accordance with those listed in the Water and Air Baseline Monitoring Guidance Document for Mine Proponents and Operators (BC MOE 2016). Samples collected for the laboratory analyses were analyzed for metals (total and dissolved), general/routine chemistry, anions and nutrients, organic carbon (total and dissolved), chemical and biochemical oxygen demand (COD and BOD), volatile organic carbons, and hydrocarbons. The results of the field blanks were checked for exceedances of the method detection limits (MDL). Blanks that exceed 2 times the MDL are commonly flagged for QA/QC concerns, as recommended by the BC Ministry of Environment (BC MOE 2013). Results from duplicate samples were compared by calculating the relative percent difference (RPD) for each parameter between the sample and it’s duplicate.
Data typenon-lab
Has viewsTrue
Hash4c7b67f943e3730f64c1f48196604a9d
Id3197dbac-1c95-48f7-9c15-6ba4c2d7ca85
Load statusInvalid header row:
Mimetypeapplication/pdf
On same domainTrue
Package id5b39d050-4dba-466a-855e-6ab1ecb9fda3
Position1
Resource citationNorth Coal Ltd (2020). Monthly Water Quality (2020-06-22) Michel Creek Watershed. Columbia Basin Water Hub. Castlegar.
Resource data disclaimerNo warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Resource locationMichel Creek, BC.
Size1.3 MiB
Stateactive
Url typeupload
Waterhub certifiedCertified
Waterhub gradeNot Reviewed
upload
Citation (Required) North Coal Ltd (2020). Monthly Water Quality (2020-06-22) Michel Creek Watershed. Columbia Basin Water Hub. Castlegar.
Resource Location Michel Creek, BC.
Data Collection Information Field methods for sample collection followed those outlined in the BC Field Sampling Manual for Continuous Monitoring and the Collection of Air, Air-Emission, Water, Wastewater, Soil, Sediment, and Biological Samples (BC MOE 2013). Samples were collected into clean, pre-labelled containers provided by ALS Environmental Laboratories. In-situ measurements of dissolved oxygen (DO), temperature, conductivity (including specific conductance), pH, and oxidation-reduction potential (ORP) were taken in the field using a YSI Pro Plus. Field blanks and duplicate samples were used to ensure accuracy and precision of the data. The results of the field blanks were checked for exceedances of the method detection limits (MDL). Blanks that exceed 2 times the MDL are commonly flagged for QA/QC concerns, as recommended by the BC Ministry of Environment (BC MOE 2013).
Data Processing Once collected, samples were stored in the field in a cooler with ice packs and additional ice and ice packs were added to the coolers before samples were shipped to ALS laboratories in Calgary. ALS is an ISO/IEC 17025 accredited full-service laboratory. Parameters analyzed were in accordance with those listed in the Water and Air Baseline Monitoring Guidance Document for Mine Proponents and Operators (BC MOE 2016). Samples collected for the laboratory analyses were analyzed for metals (total and dissolved), general/routine chemistry, anions and nutrients, organic carbon (total and dissolved), chemical and biochemical oxygen demand (COD and BOD), volatile organic carbons, and hydrocarbons. The results of the field blanks were checked for exceedances of the method detection limits (MDL). Blanks that exceed 2 times the MDL are commonly flagged for QA/QC concerns, as recommended by the BC Ministry of Environment (BC MOE 2013). Results from duplicate samples were compared by calculating the relative percent difference (RPD) for each parameter between the sample and it’s duplicate.
Data Disclaimer No warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Water Hub Data Grade Not Reviewed
Date of Most Recent Water Hub QA/QC
Loading Status Invalid header row:
Datastore Status
Data type General

Site

No data available

Parameter

No data available