Resource metadata

Field Value
Data last updated November 7, 2025
Metadata last updated November 7, 2025
Created March 28, 2024
Format CSV
License CC-BY-SA-4.0
Data collection infoTemperature and pH are measured using a Hanna Industries pen meter (HI98129) within 2-4” of the surface. Secchi depths are collected where there is sufficient depth to measure from the sampling location. Data collection is consistent with the Invasive Mussel Field Protocol prepared by the Ecosystems Branch, BC Ministry of Environment and Climate Change Strategy.
Data processingThe Water Hub has performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data typenon-lab
Datastore activeTrue
Datastore contains all records of source fileFalse
Has viewsTrue
Hash2fb01857ceafaf161456288b7156345f
Id9e03b523-ea2e-4816-a0f6-165da0bd7d87
Mimetypetext/csv
Package idc22c6d1e-73a1-4a5c-ac62-36d93ab14254
Parameter[{'accuracy': '±0.5°C', 'calibration': 'N/A', 'instrument_manufacturer': 'HANNA Instruments', 'instrument_model': 'HI98129', 'instrument_type': 'Portable Multiparameter Meter', 'notes_method': 'Low range combination meter', 'parameter': 'Water Temperature', 'parameter_unit': 'degrees celsius', 'range': '-5.0 to 60.0°C', 'resolution': '0.1°C', 'serial_number': '', 'time_zone': 'MT'}, {'accuracy': '±0.05 pH', 'calibration': 'pH is calibrated weekly', 'instrument_manufacturer': 'HANNA Instruments', 'instrument_model': 'HI98129', 'instrument_type': 'Portable Multiparameter Meter', 'notes_method': 'Low range combination meter', 'parameter': 'pH', 'parameter_unit': 'ph units', 'range': '0.00 to 14.00 pH', 'resolution': '0.01 pH', 'serial_number': '', 'time_zone': 'MT'}, {'accuracy': 'N/A', 'calibration': 'N/A', 'instrument_manufacturer': 'N/A', 'instrument_model': 'N/A', 'instrument_type': 'Secchi Disk', 'notes_method': 'Methodology consistent with Invasive Mussel Field Protocol prepared by the Ecosystems Branch, BC Ministry of Environment and Climate Change Strategy', 'parameter': 'depth', 'parameter_unit': 'metres', 'range': 'N/A', 'resolution': 'N/A', 'serial_number': '', 'time_zone': 'MT'}]
Position0
Recent qa date2024-03-28
Resource citationColumbia Shuswap Invasive Species Society. (2023). Water Quality (2023-06-05 to 2025-10-06) White Lake at Provincial Park. [Resource]. Columbia Basin Water Hub. https://doi.org/10.48511/qhna2ojo
Resource data disclaimerNo warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. Instrument accuracy may be limited. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Resource locationWhite Lake at Provincial Park.
Site[{'datum': 'WGS84', 'elevation': 1, 'latitude': 50.88818, 'longitude': -119.25704, 'site_id': 'White Lake at Provincial Park', 'site_name': 'White Lake at Provincial Park', 'waterbody': 'White Lake', 'waterbody_type': 'lake'}]
Size1.8 KiB
Stateactive
Url typeupload
Waterhub gradeCommunity Research Grade
Citation (Required) Columbia Shuswap Invasive Species Society. (2023). Water Quality (2023-06-05 to 2025-10-06) White Lake at Provincial Park. [Resource]. Columbia Basin Water Hub. https://doi.org/10.48511/qhna2ojo
Resource Location White Lake at Provincial Park.
Data Collection Information Temperature and pH are measured using a Hanna Industries pen meter (HI98129) within 2-4” of the surface. Secchi depths are collected where there is sufficient depth to measure from the sampling location. Data collection is consistent with the Invasive Mussel Field Protocol prepared by the Ecosystems Branch, BC Ministry of Environment and Climate Change Strategy.
Data Processing The Water Hub has performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data Disclaimer No warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. Instrument accuracy may be limited. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Water Hub Data Grade Community Research Grade
Date of Most Recent Water Hub QA/QC 2024-03-28
Data type General

Data Dictionary

Column Type Label Description BODC ID
date_time text
site_id text
latitude text
longitude text
notes text
water_temperature text
water_temperature_units text
pH text PHXXPR01 pH per unit volume of the water body by pH electrode SDN:P01::PHXXPR01
pH_units text
depth text Depth The length of wire between the ship and an object being lowered from a winch, which is assumed or wire-angle corrected to be the vertical distance between the ship and the object. SDN:P01::DEPHWO01
depth_units text
water_hub_qa_qc text

Site

White Lake at Provincial Park
Field Value
Site ID White Lake at Provincial Park
Site Name White Lake at Provincial Park
Waterbody Type Lake
Waterbody White Lake
Site Latitude 50.88818
Site Longitude -119.25704
Location Coordinate System WGS84
Site Elevation (masl) 1

Parameter

Water Temperature
Field Value
Parameter Water Temperature
Time Zone MT
Unit of Measurement degrees Celsius
Instrument Type Portable Multiparameter Meter
Instrument Manufacturer HANNA Instruments
Instrument Model HI98129
Serial Number
Instrument Accuracy ±0.5°C
Range -5.0 to 60.0°C
Resolution 0.1°C
Calibration Notes N/A
Notes on Method Low range combination meter
pH
Field Value
Parameter pH
Time Zone MT
Unit of Measurement pH units
Instrument Type Portable Multiparameter Meter
Instrument Manufacturer HANNA Instruments
Instrument Model HI98129
Serial Number
Instrument Accuracy ±0.05 pH
Range 0.00 to 14.00 pH
Resolution 0.01 pH
Calibration Notes pH is calibrated weekly
Notes on Method Low range combination meter
depth
Field Value
Parameter depth
Time Zone MT
Unit of Measurement metres
Instrument Type Secchi Disk
Instrument Manufacturer N/A
Instrument Model N/A
Serial Number
Instrument Accuracy N/A
Range N/A
Resolution N/A
Calibration Notes N/A
Notes on Method Methodology consistent with Invasive Mussel Field Protocol prepared by the Ecosystems Branch, BC Ministry of Environment and Climate Change Strategy