Resource metadata

Field Value
Data last updated August 27, 2025
Metadata last updated August 27, 2025
Created March 9, 2021
Format CSV
License CC-BY-NC-SA-4.0
Data collection infoTemperature measurements are taken in-stream. Water samples are collected, and analyzed in batches on the dates noted as "Analysis" in the "Remarks" column. Instruments used are calibrated as per manufacturer instructions and standards.
Data processingThe Water Hub has performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data typenon-lab
Datastore activeTrue
Datastore contains all records of source fileFalse
Has viewsTrue
Hash843cdaf3c0d5754f3f7362188626301c
Id80272bef-8530-4c46-8409-a98c67639143
Mimetypetext/csv
Package id860ca2fe-8d7a-4822-86cf-0d65377087ce
Parameter[{'accuracy': 'Unavailable', 'calibration': 'Unavailable', 'instrument_manufacturer': 'Unavailable', 'instrument_model': 'Unavailable', 'instrument_type': 'Other', 'instrument_type_other': 'N/A', 'notes_method': 'bottle dip', 'parameter': 'Water Temperature', 'parameter_unit': 'degrees celsius', 'range': 'Unavailable', 'resolution': 'Unavailable', 'serial_number': 'Unavailable', 'time_zone': 'PT'}, {'accuracy': '±0.01 pH', 'calibration': 'Calibrated before each use', 'instrument_manufacturer': 'Oaktron', 'instrument_model': 'pH 200', 'instrument_type': 'Other', 'instrument_type_other': 'N/A', 'notes_method': 'bottle dip', 'parameter': 'pH', 'parameter_unit': 'ph units', 'range': '0.00 to 14.00 pH', 'resolution': 'n/a', 'serial_number': 'Unavailable', 'time_zone': 'PT'}, {'accuracy': 'Unavailable', 'calibration': 'Conductivity Bridge calibrated annually using standard solution', 'instrument_manufacturer': 'AMRE', 'instrument_model': '2300', 'instrument_type': 'Other', 'instrument_type_other': 'N/A', 'notes_method': 'bottle dip', 'parameter': 'specific conductivity', 'parameter_unit': 'microsiemens per centimetre', 'range': 'Unavailable', 'resolution': 'Unavailable', 'serial_number': 'Unavailable', 'time_zone': 'PT'}, {'accuracy': '± 2 % of reading plus stray light', 'calibration': 'Calibrated before each use', 'instrument_manufacturer': 'Hach', 'instrument_model': '2100Q', 'instrument_type': 'Other', 'instrument_type_other': 'N/A', 'notes_method': 'bottle dip', 'parameter': 'turbidity', 'parameter_unit': 'ntu', 'range': '0-1000', 'resolution': 'n/a', 'serial_number': 'Unavailable', 'time_zone': 'PT'}, {'accuracy': 'Unavailable', 'calibration': 'Calibrated before each use', 'instrument_manufacturer': 'Unavailable', 'instrument_model': 'Unavailable', 'instrument_type': 'Other', 'instrument_type_other': 'N/A', 'notes_method': 'bottle dip', 'parameter': 'conductivity', 'parameter_unit': 'microsiemens per centimetre', 'range': 'Unavailable', 'resolution': 'Unavailable', 'serial_number': 'Unavailable', 'time_zone': 'PT'}, {'accuracy': 'Unavailable', 'calibration': 'Calibrated before each use', 'instrument_manufacturer': 'Unavailable', 'instrument_model': 'Unavailable', 'instrument_type': 'Other', 'instrument_type_other': 'N/A', 'notes_method': 'Temperature during analysis of water sample', 'parameter': 'temperature at analysis', 'parameter_unit': 'degrees celsius', 'range': 'Unavailable', 'resolution': 'Unavailable', 'serial_number': 'Unavailable', 'time_zone': 'PT'}]
Position0
Resource citationSlocan Lake Stewardship Society. (2021) Water Quality Monitoring (2017-2024) Wilson Creek. Columbia Basin Water Hub. [Resource]. Rosebery. https://doi.org/10.48511/w74xv97m
Resource data disclaimerNo warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. Some metadata may be missing from this file. Instrument accuracy may be limited. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Resource locationWilson Creek near Rosebery
Site[{'datum': 'NAD83', 'elevation': 562, 'latitude': 50.03238, 'longitude': -117.4043, 'site_id': 'wilson_creek', 'site_name': 'Rosebery', 'waterbody': 'wilson creek', 'waterbody_type': 'stream/river'}]
Size34.9 KiB
Stateactive
Url typeupload
Waterhub gradeCommunity Research Grade
Citation (Required) Slocan Lake Stewardship Society. (2021) Water Quality Monitoring (2017-2024) Wilson Creek. Columbia Basin Water Hub. [Resource]. Rosebery. https://doi.org/10.48511/w74xv97m
Resource Location Wilson Creek near Rosebery
Data Collection Information Temperature measurements are taken in-stream. Water samples are collected, and analyzed in batches on the dates noted as "Analysis" in the "Remarks" column. Instruments used are calibrated as per manufacturer instructions and standards.
Data Processing The Water Hub has performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data Disclaimer No warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. Some metadata may be missing from this file. Instrument accuracy may be limited. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Water Hub Data Grade Community Research Grade
Date of Most Recent Water Hub QA/QC
Data type General

Data Dictionary

Column Type Label Description BODC ID
date_time text
site_id text
latitude text
longitude text
notes text
water_temperature text
water_temperature_units text
pH text PHXXPR01 pH per unit volume of the water body by pH electrode SDN:P01::PHXXPR01
pH_units text
specific_conductivity text
specific_conductivity_units text
turbidity text Turbidity Estimate of suspended sediment concentration based on the proportion of a light transmission in the water column that is reflected back to a co-located receiver. SDN:P01::TURBXXXX
turbidity_units text
conductivity text Cond This is the preferred term for this definition. Alternative codes (PCONCS01 and PCONZZ01) are undesired duplicates from BODC history and should not be used. SDN:P01::CNDCZZ01
conductivity_units text
temperature_at_analysis text
temperature_at_analysis_units text
water_hub_qa_qc text

Site

wilson_creek
Field Value
Site ID wilson_creek
Site Name Rosebery
Waterbody Type Stream/River
Waterbody wilson creek
Site Latitude 50.03238
Site Longitude -117.4043
Location Coordinate System NAD83
Site Elevation (masl) 562

Parameter

Water Temperature
Field Value
Parameter Water Temperature
Time Zone PT
Unit of Measurement degrees Celsius
Instrument Type Other
Other N/A
Instrument Manufacturer Unavailable
Instrument Model Unavailable
Serial Number Unavailable
Instrument Accuracy Unavailable
Range Unavailable
Resolution Unavailable
Calibration Notes Unavailable
Notes on Method bottle dip
pH
Field Value
Parameter pH
Time Zone PT
Unit of Measurement pH units
Instrument Type Other
Other N/A
Instrument Manufacturer Oaktron
Instrument Model pH 200
Serial Number Unavailable
Instrument Accuracy ±0.01 pH
Range 0.00 to 14.00 pH
Resolution n/a
Calibration Notes Calibrated before each use
Notes on Method bottle dip
specific conductivity
Field Value
Parameter specific conductivity
Time Zone PT
Unit of Measurement microSiemens per centimetre
Instrument Type Other
Other N/A
Instrument Manufacturer AMRE
Instrument Model 2300
Serial Number Unavailable
Instrument Accuracy Unavailable
Range Unavailable
Resolution Unavailable
Calibration Notes Conductivity Bridge calibrated annually using standard solution
Notes on Method bottle dip
turbidity
Field Value
Parameter turbidity
Time Zone PT
Unit of Measurement NTU
Instrument Type Other
Other N/A
Instrument Manufacturer Hach
Instrument Model 2100Q
Serial Number Unavailable
Instrument Accuracy ± 2 % of reading plus stray light
Range 0-1000
Resolution n/a
Calibration Notes Calibrated before each use
Notes on Method bottle dip
conductivity
Field Value
Parameter conductivity
Time Zone PT
Unit of Measurement microSiemens per centimetre
Instrument Type Other
Other N/A
Instrument Manufacturer Unavailable
Instrument Model Unavailable
Serial Number Unavailable
Instrument Accuracy Unavailable
Range Unavailable
Resolution Unavailable
Calibration Notes Calibrated before each use
Notes on Method bottle dip
temperature at analysis
Field Value
Parameter temperature at analysis
Time Zone PT
Unit of Measurement degrees Celsius
Instrument Type Other
Other N/A
Instrument Manufacturer Unavailable
Instrument Model Unavailable
Serial Number Unavailable
Instrument Accuracy Unavailable
Range Unavailable
Resolution Unavailable
Calibration Notes Calibrated before each use
Notes on Method Temperature during analysis of water sample