Changes
On March 18, 2022 at 5:42:22 AM UTC, lladmin:
-
Added the following tags to Water Quality Monitoring Michel Creek Watershed 2022
-
Changed the license of Water Quality Monitoring Michel Creek Watershed 2022 to CC-BY-NC-SA-4.0 (previously None)
-
Added resource Monthly Water Quality (2022-01-10) Michel Creek Watershed to Water Quality Monitoring Michel Creek Watershed 2022
-
Added resource Monthly Water Quality (2022-02-08) Michel Creek Watershed to Water Quality Monitoring Michel Creek Watershed 2022
f | 1 | { | f | 1 | { |
2 | "author": null, | 2 | "author": null, | ||
3 | "author_email": null, | 3 | "author_email": null, | ||
n | n | 4 | "citation": "North Coal Ltd (2022). Water Quality Monitoring Michel | ||
5 | Creek Watershed 2021. Columbia Basin Water Hub. Castlegar.", | ||||
6 | "creator": "Lotic Environmental Ltd.", | ||||
4 | "creator_user_id": "43786263-64cd-4839-a454-f41196586786", | 7 | "creator_user_id": "43786263-64cd-4839-a454-f41196586786", | ||
n | n | 8 | "data_disclaimer": "No warranty or guarantee exists that the | ||
9 | information is accurate, complete, current, or suitable for any | ||||
10 | purpose. The individual user must confirm the accuracy of the data and | ||||
11 | whether it will be appropriate for their purpose.", | ||||
12 | "data_type": "Stream", | ||||
13 | "end_date": "2022-12-31", | ||||
14 | "funding_reference": "N/A", | ||||
15 | "groups": [], | ||||
5 | "id": "2dfadf11-a95d-4d75-8448-006d733d430e", | 16 | "id": "2dfadf11-a95d-4d75-8448-006d733d430e", | ||
n | n | 17 | "identifier": "", | ||
18 | "isopen": false, | ||||
19 | "keywords": "Lotic,Metals,Stream,Water Quality,Technical Research | ||||
20 | Grade", | ||||
21 | "latitude": "49.669", | ||||
6 | "license_id": "CC-BY-NC-SA-4.0", | 22 | "license_id": "CC-BY-NC-SA-4.0", | ||
n | n | 23 | "license_title": "CC-BY-NC-SA-4.0", | ||
24 | "location": "Michel Creek, Sparwood BC.", | ||||
25 | "longitude": "-114.778", | ||||
7 | "maintainer": null, | 26 | "maintainer": null, | ||
8 | "maintainer_email": "acousins@northcoal.ca", | 27 | "maintainer_email": "acousins@northcoal.ca", | ||
9 | "metadata_created": "2022-01-19T16:42:59.560769", | 28 | "metadata_created": "2022-01-19T16:42:59.560769", | ||
n | 10 | "metadata_modified": "2022-02-17T17:36:51.182975", | n | 29 | "metadata_modified": "2022-03-18T05:42:22.347981", |
11 | "name": "water-quality-monitoring-michel-creek-watershed-2022", | 30 | "name": "water-quality-monitoring-michel-creek-watershed-2022", | ||
12 | "notes": "This program focuses on ongoing monitoring of water | 31 | "notes": "This program focuses on ongoing monitoring of water | ||
13 | quality parameters identified to be of importance to the Michel Coal | 32 | quality parameters identified to be of importance to the Michel Coal | ||
14 | Project. There are 10 samples collected on a monthly basis at three | 33 | Project. There are 10 samples collected on a monthly basis at three | ||
15 | sites. High frequency sampling, which includes five sampling events | 34 | sites. High frequency sampling, which includes five sampling events | ||
16 | within a 30 day period (inclusive of one monthly sampling event), is | 35 | within a 30 day period (inclusive of one monthly sampling event), is | ||
17 | carried out during times of high and low flow.", | 36 | carried out during times of high and low flow.", | ||
n | n | 37 | "num_resources": 2, | ||
38 | "num_tags": 5, | ||||
39 | "organization": { | ||||
40 | "approval_status": "approved", | ||||
41 | "created": "2021-06-28T15:00:37.879015", | ||||
42 | "description": "North Coal is in the advanced stages of developing | ||||
43 | the steelmaking Michel Coal project with an expected 25-year mine-life | ||||
44 | that will sustain jobs and support the local and provincial economy. | ||||
45 | Based in Sparwood, British Columbia, the Michel Coal project is | ||||
46 | located in a region with longstanding mine operations and | ||||
47 | infrastructure.\r\n\r\nOur overriding goal is to make positive social, | ||||
48 | economic, and environmental contributions within the communities where | ||||
49 | we operate and live. We are committed to safe operations, | ||||
50 | collaboration with First Nations and local communities, sustainable | ||||
51 | land stewardship, and minimized environmental impact.", | ||||
52 | "id": "6490a8f8-204e-46f1-b2c0-f818525a605c", | ||||
53 | "image_url": "2021-06-28-220037.866500Northcoaliconset-10.png", | ||||
54 | "is_organization": true, | ||||
55 | "name": "north-coal", | ||||
56 | "state": "active", | ||||
57 | "title": "North Coal", | ||||
58 | "type": "organization" | ||||
59 | }, | ||||
60 | "other_sources": "N/A", | ||||
18 | "owner_org": "6490a8f8-204e-46f1-b2c0-f818525a605c", | 61 | "owner_org": "6490a8f8-204e-46f1-b2c0-f818525a605c", | ||
19 | "private": false, | 62 | "private": false, | ||
n | 20 | "revision_id": "f040a474-85f5-48f0-9d25-cb9a259ee9dc", | n | 63 | "publication_year": "2022", |
64 | "relationships_as_object": [], | ||||
65 | "relationships_as_subject": [], | ||||
66 | "resources": [ | ||||
67 | { | ||||
68 | "cache_last_updated": null, | ||||
69 | "cache_url": null, | ||||
70 | "created": "2022-01-19T16:46:30.022208", | ||||
71 | "data_collection_info": "Field methods for sample collection | ||||
72 | followed those outlined in the BC Field Sampling Manual for Continuous | ||||
73 | Monitoring and the Collection of Air, Air-Emission, Water, Wastewater, | ||||
74 | Soil, Sediment, and Biological Samples (BC MOE 2013). Samples were | ||||
75 | collected into clean, pre-labelled containers provided by ALS | ||||
76 | Environmental Laboratories. In-situ measurements of dissolved oxygen | ||||
77 | (DO), temperature, conductivity (including specific conductance), pH, | ||||
78 | and oxidation-reduction potential (ORP) were taken in the field using | ||||
79 | a YSI Pro Plus. Field blanks and duplicate samples were used to ensure | ||||
80 | accuracy and precision of the data. The results of the field blanks | ||||
81 | were checked for exceedances of the method detection limits (MDL). | ||||
82 | Blanks that exceed 2 times the MDL are commonly flagged for QA/QC | ||||
83 | concerns, as recommended by the BC Ministry of Environment (BC MOE | ||||
84 | 2013).", | ||||
85 | "data_processing": "Once collected, samples were stored in the | ||||
86 | field in a cooler with ice packs and additional ice and ice packs were | ||||
87 | added to the coolers before samples were shipped to ALS laboratories | ||||
88 | in Calgary. ALS is an ISO/IEC 17025 accredited full-service | ||||
89 | laboratory. Parameters analyzed were in accordance with those listed | ||||
90 | in the Water and Air Baseline Monitoring Guidance Document for Mine | ||||
91 | Proponents and Operators (BC MOE 2016). Samples collected for the | ||||
92 | laboratory analyses were analyzed for metals (total and dissolved), | ||||
93 | general/routine chemistry, anions and nutrients, organic carbon (total | ||||
94 | and dissolved), chemical and biochemical oxygen demand (COD and BOD), | ||||
95 | volatile organic carbons, and hydrocarbons. The results of the field | ||||
96 | blanks were checked for exceedances of the method detection limits | ||||
97 | (MDL). Blanks that exceed 2 times the MDL are commonly flagged for | ||||
98 | QA/QC concerns, as recommended by the BC Ministry of Environment (BC | ||||
99 | MOE 2013). Results from duplicate samples were compared by calculating | ||||
100 | the relative percent difference (RPD) for each parameter between the | ||||
101 | sample and it\u2019s duplicate.", | ||||
102 | "datastore_active": false, | ||||
103 | "description": "This resource is part of North Coal Ltd's | ||||
104 | ongoing water quality monitoring program. This record includes data | ||||
105 | collected from January 2022.", | ||||
106 | "format": "PDF", | ||||
107 | "hash": "4e882e9770221227ef8a3ad9e1ebcc3c", | ||||
108 | "header_row": "", | ||||
109 | "id": "42fbd48c-6808-41fd-bc7d-d33ea90b452e", | ||||
110 | "last_modified": "2022-01-19T16:46:29.975643", | ||||
111 | "load_status": "Invalid header row: ", | ||||
112 | "metadata_modified": "2022-01-19T16:46:30.022208", | ||||
113 | "mimetype": "application/pdf", | ||||
114 | "mimetype_inner": null, | ||||
115 | "name": "Monthly Water Quality (2022-01-10) Michel Creek | ||||
116 | Watershed", | ||||
117 | "package_id": "2dfadf11-a95d-4d75-8448-006d733d430e", | ||||
118 | "position": 0, | ||||
119 | "resource_citation": "North Coal Ltd (2022). Monthly Water | ||||
120 | Quality (2022-01-10) Michel Creek Watershed. Columbia Basin Water Hub. | ||||
121 | Castlegar.", | ||||
122 | "resource_data_disclaimer": "No warranty or guarantee exists | ||||
123 | that the information is accurate, complete, current, or suitable for | ||||
124 | any purpose. The individual user must confirm the accuracy of the data | ||||
125 | and whether it will be appropriate for their purpose.", | ||||
126 | "resource_location": "Michel Creek, BC.", | ||||
127 | "resource_type": null, | ||||
128 | "size": 698634, | ||||
129 | "state": "active", | ||||
130 | "url": | ||||
131 | d48c-6808-41fd-bc7d-d33ea90b452e/download/cg2200279_0_coa-merged.pdf", | ||||
132 | "url_type": "upload", | ||||
133 | "waterhub_certified": "Certified", | ||||
134 | "waterhub_grade": "Not Reviewed" | ||||
135 | }, | ||||
136 | { | ||||
137 | "cache_last_updated": null, | ||||
138 | "cache_url": null, | ||||
139 | "created": "2022-02-17T17:36:49.974605", | ||||
140 | "data_collection_info": "Field methods for sample collection | ||||
141 | followed those outlined in the BC Field Sampling Manual for Continuous | ||||
142 | Monitoring and the Collection of Air, Air-Emission, Water, Wastewater, | ||||
143 | Soil, Sediment, and Biological Samples (BC MOE 2013). Samples were | ||||
144 | collected into clean, pre-labelled containers provided by ALS | ||||
145 | Environmental Laboratories. In-situ measurements of dissolved oxygen | ||||
146 | (DO), temperature, conductivity (including specific conductance), pH, | ||||
147 | and oxidation-reduction potential (ORP) were taken in the field using | ||||
148 | a YSI Pro Plus. Field blanks and duplicate samples were used to ensure | ||||
149 | accuracy and precision of the data. The results of the field blanks | ||||
150 | were checked for exceedances of the method detection limits (MDL). | ||||
151 | Blanks that exceed 2 times the MDL are commonly flagged for QA/QC | ||||
152 | concerns, as recommended by the BC Ministry of Environment (BC MOE | ||||
153 | 2013).", | ||||
154 | "data_processing": "Once collected, samples were stored in the | ||||
155 | field in a cooler with ice packs and additional ice and ice packs were | ||||
156 | added to the coolers before samples were shipped to ALS laboratories | ||||
157 | in Calgary. ALS is an ISO/IEC 17025 accredited full-service | ||||
158 | laboratory. Parameters analyzed were in accordance with those listed | ||||
159 | in the Water and Air Baseline Monitoring Guidance Document for Mine | ||||
160 | Proponents and Operators (BC MOE 2016). Samples collected for the | ||||
161 | laboratory analyses were analyzed for metals (total and dissolved), | ||||
162 | general/routine chemistry, anions and nutrients, organic carbon (total | ||||
163 | and dissolved), chemical and biochemical oxygen demand (COD and BOD), | ||||
164 | volatile organic carbons, and hydrocarbons. The results of the field | ||||
165 | blanks were checked for exceedances of the method detection limits | ||||
166 | (MDL). Blanks that exceed 2 times the MDL are commonly flagged for | ||||
167 | QA/QC concerns, as recommended by the BC Ministry of Environment (BC | ||||
168 | MOE 2013). Results from duplicate samples were compared by calculating | ||||
169 | the relative percent difference (RPD) for each parameter between the | ||||
170 | sample and it\u2019s duplicate.", | ||||
171 | "datastore_active": false, | ||||
172 | "description": "This resource is part of North Coal Ltd's | ||||
173 | ongoing water quality monitoring program. This record includes data | ||||
174 | collected from February 2022.", | ||||
175 | "format": "PDF", | ||||
176 | "hash": "6fe205237d4bb37bb0726ebc39ff953f", | ||||
177 | "header_row": "", | ||||
178 | "id": "7181e46e-ca09-4852-82ee-77d2b19c520f", | ||||
179 | "last_modified": "2022-02-17T17:36:49.929966", | ||||
180 | "load_status": "Invalid header row: ", | ||||
181 | "metadata_modified": "2022-02-17T17:36:49.974605", | ||||
182 | "mimetype": "application/pdf", | ||||
183 | "mimetype_inner": null, | ||||
184 | "name": "Monthly Water Quality (2022-02-08) Michel Creek | ||||
185 | Watershed", | ||||
186 | "package_id": "2dfadf11-a95d-4d75-8448-006d733d430e", | ||||
187 | "position": 1, | ||||
188 | "resource_citation": "North Coal Ltd (2022). Monthly Water | ||||
189 | Quality (2022-02-08) Michel Creek Watershed. Columbia Basin Water Hub. | ||||
190 | Castlegar.", | ||||
191 | "resource_data_disclaimer": "No warranty or guarantee exists | ||||
192 | that the information is accurate, complete, current, or suitable for | ||||
193 | any purpose. The individual user must confirm the accuracy of the data | ||||
194 | and whether it will be appropriate for their purpose.", | ||||
195 | "resource_location": "Michel Creek, BC.", | ||||
196 | "resource_type": null, | ||||
197 | "size": 538359, | ||||
198 | "state": "active", | ||||
199 | "url": | ||||
200 | e46e-ca09-4852-82ee-77d2b19c520f/download/cg2201456_0_coa-merged.pdf", | ||||
201 | "url_type": "upload", | ||||
202 | "waterhub_certified": "Certified", | ||||
203 | "waterhub_grade": "Not Reviewed" | ||||
204 | } | ||||
205 | ], | ||||
206 | "start_date": "2022-01-01", | ||||
21 | "state": "active", | 207 | "state": "active", | ||
t | t | 208 | "tags": [ | ||
209 | { | ||||
210 | "display_name": "Lotic", | ||||
211 | "id": "3465589a-61eb-4556-a9b4-84f8661c2c0a", | ||||
212 | "name": "Lotic", | ||||
213 | "state": "active", | ||||
214 | "vocabulary_id": null | ||||
215 | }, | ||||
216 | { | ||||
217 | "display_name": "Metals", | ||||
218 | "id": "10271145-f032-4164-9c59-74d8a78e5c34", | ||||
219 | "name": "Metals", | ||||
220 | "state": "active", | ||||
221 | "vocabulary_id": null | ||||
222 | }, | ||||
223 | { | ||||
224 | "display_name": "Stream", | ||||
225 | "id": "208421f0-ebb5-4b32-8111-2ff156803d73", | ||||
226 | "name": "Stream", | ||||
227 | "state": "active", | ||||
228 | "vocabulary_id": null | ||||
229 | }, | ||||
230 | { | ||||
231 | "display_name": "Technical Research Grade", | ||||
232 | "id": "97d8e587-1cbd-450e-96a0-e8cfad092b83", | ||||
233 | "name": "Technical Research Grade", | ||||
234 | "state": "active", | ||||
235 | "vocabulary_id": null | ||||
236 | }, | ||||
237 | { | ||||
238 | "display_name": "Water Quality", | ||||
239 | "id": "12fe3ab5-fdaf-44c5-8167-06c7589d90f3", | ||||
240 | "name": "Water Quality", | ||||
241 | "state": "active", | ||||
242 | "vocabulary_id": null | ||||
243 | } | ||||
244 | ], | ||||
22 | "title": "Water Quality Monitoring Michel Creek Watershed 2022", | 245 | "title": "Water Quality Monitoring Michel Creek Watershed 2022", | ||
23 | "type": "dataset", | 246 | "type": "dataset", | ||
24 | "url": null, | 247 | "url": null, | ||
25 | "version": null | 248 | "version": null | ||
26 | } | 249 | } |