Skip to content

Changes

View changes from to


On August 15, 2022 at 9:58:03 PM UTC, Gravatar ameliasmart98:
  • Set format of resource Groundwater (2020-01-06 to 2021-04-30) LLC VOW 14 to URL (previously XLSX) in LLC VOW 14 (WTN 103641)


  • Updated description of resource Groundwater (2020-01-06 to 2021-04-30) LLC VOW 14 in LLC VOW 14 (WTN 103641) from

    This resource is part of the Living Lakes Canada Upper Columbia Basin Groundwater Monitoring Program, and contains a groundwater monitoring record for VOW 14 from 2020-01-06 to 2020-01-04. Water levels are reported in meters below ground surface. This resource will be updated periodically to add new data.
    to
    This resource is part of the Living Lakes Canada Upper Columbia Basin Groundwater Monitoring Program, and contains a groundwater monitoring record for VOW 14 from 2020-01-06 to 2020-01-04. Water levels are reported in meters below ground surface.


  • Uploaded a new file to resource Groundwater (2020-01-06 to 2021-04-30) LLC VOW 14 in LLC VOW 14 (WTN 103641)


  • Removed the value of field header_row in resource Groundwater (2020-01-06 to 2021-04-30) LLC VOW 14 in LLC VOW 14 (WTN 103641)


  • Removed the value of field url_type in resource Groundwater (2020-01-06 to 2021-04-30) LLC VOW 14 in LLC VOW 14 (WTN 103641)


  • Changed value of field data_collection_info of resource Groundwater (2020-01-06 to 2021-04-30) LLC VOW 14 to Continuous (hourly) water level data were collected with a HOBO MX 2001 Bluetooth (4 meter range) water level logger. The data logger determines water levels by continuously collecting the absolute pressure of the water column above a sensor, compensating it for atmospheric pressure, and calibrating it with reference water levels that are collected manually. The atmospheric pressure is measured by a barometric sensor in the MX2001 top end unit that is installed in the airspace at the top of the wellhead. Manual water level level measurements were collected using either a Heron or Solinst water level tape (sounding tape). Water Level: Hobo MX2001 - 04 (Accuracy: Typical error: ±0.075% FS, 0.3 cm (0.01 ft) water. Maximum error: ±0.15% FS, 0.6 cm (0.02 ft) water) Water Temperature: Hobo Mx2001 - 04 (Range: -20° to 50°C; Accuracy: ±0.44°C from 0° to 50°C) (previously Continuous (hourly) water level data were collected with a HOBO MX 2001 Bluetooth (4 meter range) water level logger. The data logger determines water levels by continuously collecting the absolute pressure of the water column above a sensor, compensating it for atmospheric pressure, and calibrating it with reference water levels that are collected manually. The atmospheric pressure is measured by a barometric sensor in the MX2001 top end unit that is installed in the airspace at the top of the wellhead. Manual water level level measurements were collected using either a Heron or Solinst water level tape (sounding tape).) in LLC VOW 14 (WTN 103641)