Skip to content

Changes

View changes from to


On December 12, 2023 at 8:07:14 PM UTC, Gravatar mchevalot:
  • Changed value of field parameter of resource Turbidity and Flow (1993-04-01 to 2019-07-31) Redfish Creek to [{'accuracy': 'Not specified', 'calibration': 'Not specified', 'instrument_manufacturer': 'Not specified', 'instrument_model': 'Not specified', 'instrument_type': 'Unknown', 'notes_method': 'WSC site ', 'parameter': 'Discharge', 'parameter_unit': 'metres3 per second', 'resolution': 'Not specified', 'serial_number': 1, 'time_zone': 'PT'}, {'accuracy': 'Not specified', 'calibration': 'Not specified', 'instrument_manufacturer': 'Not specified', 'instrument_model': 'Not specified', 'instrument_type': 'Unknown', 'notes_method': 'Where multiple readings are taken, an average is provided', 'parameter': 'turbidity', 'parameter_unit': 'ntu', 'resolution': 'Not specified', 'serial_number': 1, 'time_zone': 'PT'}, {'accuracy': 'Not specified', 'calibration': 'Not specified', 'instrument_manufacturer': 'Not specified', 'instrument_model': 'Not specified', 'instrument_type': 'Unknown', 'notes_method': 'Where multiple readings are taken, an average is provided', 'parameter': 'turbidity', 'parameter_unit': 'ntu', 'resolution': 'Not specified', 'serial_number': 1, 'time_zone': 'PT'}, {'accuracy': '±5% RDG or 0.5 NTU', 'calibration': 'Calibrated with each use', 'instrument_manufacturer': 'Sper Scientific', 'instrument_model': '860040', 'instrument_type': 'Other', 'instrument_type_other': 'turbidity meter', 'notes_method': 'Monitoring conducted by Laird Creek Water Users. Four readings taken, average provided. <.05 Means readings include multiple 0.0 values and average is below .05 NTU (avg. Of 4 samples)', 'parameter': 'turbidity', 'parameter_unit': 'ntu', 'resolution': '0.01 NTU', 'serial_number': 1, 'time_zone': 'PT'}, {'accuracy': '±1% F.S. (excluding probe error)', 'calibration': 'Calibrated at the start of each season', 'instrument_manufacturer': 'Hanna Instruments', 'instrument_model': 'HI9033', 'instrument_type': 'Other', 'instrument_type_other': 'Conductivity meter', 'notes_method': 'Monitoring conducted by Laird Creek Water Users. Four readings taken, average provided', 'parameter': 'conductivity', 'parameter_unit': 'microsiemens per centimetre', 'resolution': '0.1 µS/cm', 'serial_number': 1, 'time_zone': 'PT'}, {'accuracy': 'N/A', 'calibration': 'N/A', 'instrument_manufacturer': 'N/A', 'instrument_model': 'N/A', 'instrument_type': 'Other', 'instrument_type_other': 'N/A', 'notes_method': 'N/A', 'parameter': 'weather and notes', 'parameter_unit': 'observation', 'resolution': 'N/A', 'serial_number': 1, 'time_zone': 'PT'}] (previously [{'accuracy': 'Not specified', 'calibration': 'Not specified', 'instrument_manufacturer': 'Not specified', 'instrument_model': 'Not specified', 'instrument_type': 'Unknown', 'notes_method': 'WSC site ', 'parameter': 'Discharge', 'parameter_unit': 'metres3 per second', 'resolution': 'Not specified', 'serial_number': 1, 'time_zone': 'PT'}, {'accuracy': 'Not specified', 'calibration': 'Not specified', 'instrument_manufacturer': 'Not specified', 'instrument_model': 'Not specified', 'instrument_type': 'Unknown', 'notes_method': 'Where multiple readings are taken, an average is provided', 'parameter': 'turbidity', 'parameter_unit': 'ntu', 'resolution': 'Not specified', 'serial_number': 1, 'time_zone': 'PT'}, {'accuracy': 'Not specified', 'calibration': 'Not specified', 'instrument_manufacturer': 'Not specified', 'instrument_model': 'Not specified', 'instrument_type': 'Unknown', 'notes_method': 'Where multiple readings are taken, an average is provided', 'parameter': 'turbidity', 'parameter_unit': 'ntu', 'resolution': 'Not specified', 'serial_number': 1, 'time_zone': 'PT'}, {'accuracy': '±5% RDG or 0.5 NTU', 'calibration': 'Calibrated with each use', 'instrument_manufacturer': 'Sper Scientific', 'instrument_model': '860040', 'instrument_type': 'Other', 'instrument_type_other': 'turbidity meter', 'notes_method': 'Monitoring conducted by Laird Creek Water Users. Four readings taken, average provided. <.05 Means readings include multiple 0.0 values and average is below .05 NTU (avg. Of 4 samples)', 'parameter': 'turbidity', 'parameter_unit': 'ntu', 'resolution': '0.01 NTU', 'serial_number': 1, 'time_zone': 'PT'}, {'accuracy': '±1% F.S. (excluding probe error)', 'calibration': 'Calibrated at the start of each season', 'instrument_manufacturer': 'Hanna Instruments', 'instrument_model': 'HI9033', 'instrument_type': 'Other', 'instrument_type_other': 'Conductivity meter', 'notes_method': 'Monitoring conducted by Laird Creek Water Users. Four readings taken, average provided', 'parameter': 'conductivity', 'parameter_unit': 'microsiemens per centimetre', 'resolution': '0.1 µS/cm', 'serial_number': 1, 'time_zone': 'PT'}, {'accuracy': 'N/A', 'calibration': 'N/A', 'instrument_manufacturer': 'N/A', 'instrument_model': 'N/A', 'instrument_type': 'Other', 'instrument_type_other': 'N/A', 'notes_method': 'N/A', 'parameter': 'weather and notes', 'parameter_unit': 'n/a', 'resolution': 'N/A', 'serial_number': 1, 'time_zone': 'PT'}]) in Redfish Creek Water Quality