Skip to content

Changes

View changes from to


On January 24, 2024 at 11:18:53 AM UTC, Gravatar mchevalot:
  • Changed value of field parameter of resource Water Quality (2017-12-02 to 2021-12-27) Silverton Creek (NJSLV01) to [{'accuracy': 'Unavailable', 'calibration': 'Unavailable', 'instrument_manufacturer': 'Unavailable', 'instrument_model': 'Unavailable', 'instrument_type': 'Unknown', 'notes_method': 'in stream', 'parameter': 'Water Temperature', 'parameter_unit': 'degrees celsius', 'range': 'Unavailable', 'resolution': 'n/a', 'serial_number': 'Unavailable', 'time_zone': 'PT'}, {'accuracy': '±0.01 pH', 'calibration': 'Calibrated before each use', 'instrument_manufacturer': 'Oaktron', 'instrument_model': 'pH 200', 'instrument_type': 'Other', 'instrument_type_other': 'pH meter', 'notes_method': 'bottle dip', 'parameter': 'pH', 'parameter_unit': 'ph units', 'range': '0.00 to 14.00 pH', 'resolution': 'n/a', 'serial_number': 'Unavailable', 'time_zone': 'PT'}, {'accuracy': 'Unavailable', 'calibration': 'Conductivity Bridge calibrated annually using standard solution', 'instrument_manufacturer': 'AMRE', 'instrument_model': '2300', 'instrument_type': 'Other', 'instrument_type_other': 'conductivity meter', 'notes_method': 'bottle dip', 'parameter': 'specific conductivity', 'parameter_unit': 'microsiemens per centimetre', 'range': 'Unavailable', 'resolution': 'n/a', 'serial_number': 'Unavailable', 'time_zone': 'PT'}, {'accuracy': '± 2 % of reading plus stray light', 'calibration': 'Calibrated before each use', 'instrument_manufacturer': 'Hach', 'instrument_model': '2100Q', 'instrument_type': 'Other', 'instrument_type_other': 'Portable Turbidimeter', 'notes_method': 'bottle dip', 'parameter': 'turbidity', 'parameter_unit': 'ntu', 'range': '0-1000', 'resolution': 'n/a', 'serial_number': 'Unavailable', 'time_zone': 'PT'}, {'accuracy': 'unavailable', 'calibration': 'Calibrated before each use', 'instrument_manufacturer': 'unavailable', 'instrument_model': 'unavailable', 'instrument_type': 'Unknown', 'notes_method': 'bottle dip', 'parameter': 'conductivity', 'parameter_unit': 'microsiemens per centimetre', 'range': 'Unavailable', 'resolution': 'n/a', 'serial_number': 'Unavailable', 'time_zone': 'PT'}, {'accuracy': 'Unavailable', 'calibration': 'Calibrated before each use', 'instrument_manufacturer': 'Unavailable', 'instrument_model': 'Unavailable', 'instrument_type': 'Unknown', 'notes_method': 'bottle dip', 'parameter': 'temperature at analysis', 'parameter_unit': 'degrees celsius', 'range': 'Unavailable', 'resolution': 'n/a', 'serial_number': 'Unavailable', 'time_zone': 'PT'}] (previously [{'accuracy': 'Unavailable', 'calibration': 'Unavailable', 'instrument_manufacturer': 'Unavailable', 'instrument_model': 'Unavailable', 'instrument_type': 'Unknown', 'notes_method': 'in stream', 'parameter': 'Water Temperature', 'parameter_unit': 'degrees celsius', 'resolution': 'n/a', 'serial_number': 1, 'time_zone': 'PT'}, {'accuracy': '±0.01 pH', 'calibration': 'Calibrated before each use', 'instrument_manufacturer': 'Oaktron', 'instrument_model': 'pH 200', 'instrument_type': 'Other', 'instrument_type_other': 'pH meter', 'notes_method': 'bottle dip', 'parameter': 'pH', 'parameter_unit': 'ph units', 'resolution': 'n/a', 'serial_number': 1, 'time_zone': 'PT'}, {'accuracy': 'Unavailable', 'calibration': 'Conductivity Bridge calibrated annually using standard solution', 'instrument_manufacturer': 'AMRE', 'instrument_model': '2300', 'instrument_type': 'Other', 'instrument_type_other': 'conductivity meter', 'notes_method': 'bottle dip', 'parameter': 'specific conductivity', 'parameter_unit': 'microsiemens per centimetre', 'resolution': 'n/a', 'serial_number': 1, 'time_zone': 'PT'}, {'accuracy': '± 2 % of reading plus stray light', 'calibration': 'Calibrated before each use', 'instrument_manufacturer': 'Hach', 'instrument_model': '2100Q', 'instrument_type': 'Other', 'instrument_type_other': 'Portable Turbidimeter', 'notes_method': 'bottle dip', 'parameter': 'turbidity', 'parameter_unit': 'ntu', 'resolution': 'n/a', 'serial_number': 1, 'time_zone': 'PT'}, {'accuracy': 'unavailable', 'calibration': 'Calibrated before each use', 'instrument_manufacturer': 'unavailable', 'instrument_model': 'unavailable', 'instrument_type': 'Unknown', 'notes_method': 'bottle dip', 'parameter': 'conductivity', 'parameter_unit': 'microsiemens per centimetre', 'resolution': 'n/a', 'serial_number': 1, 'time_zone': 'PT'}, {'accuracy': 'Unavailable', 'calibration': 'Calibrated before each use', 'instrument_manufacturer': 'Unavailable', 'instrument_model': 'Unavailable', 'instrument_type': 'Unknown', 'notes_method': 'bottle dip', 'parameter': 'temperature at analysis', 'parameter_unit': 'degrees celsius', 'resolution': 'n/a', 'serial_number': 1, 'time_zone': 'PT'}]) in Silverton Creek (NJSLV01)