Resource metadata

Field Value
Data last updated November 12, 2024
Metadata last updated November 18, 2024
Created October 15, 2024
Format CSV
License CC-BY-SA-4.0
Data collection infoA pressure logger is deployed at the hydrometric station. Measurements are recorded at 5 minute intervals.
Data processingData review, outlier trimming, stage-discharge relationship evaluation, internal computations to convert pressure measurements to stream discharge.
Data typenon-lab
Datastore activeTrue
Datastore contains all records of source fileFalse
Datastore statuspending
Has viewsTrue
Hash8a2670ffbef0c71569abec7c0b84f75b
Header row1
Id09d63e9a-c03c-4268-a5b2-833ec6eb6805
Load statusTable was successfully loaded: 233212 rows
Mimetypetext/csv
Package id681f4c8f-d27c-4925-87c3-61f1da55cdf8
Parameter[{'accuracy': '± 0.05% FS (Barologger 5: ± 0.05 kPa)', 'calibration': 'Calibrated accordingly', 'instrument_manufacturer': 'Solinst', 'instrument_model': '3250 LevelVent 5 ', 'instrument_type': 'Data Logger', 'notes_method': 'N/A', 'parameter': 'Discharge', 'parameter_unit': 'metres3 per second', 'range': '0º to 50ºC (Barologger 5: -10 to +50ºC)', 'resolution': '0.002% FS to 0.0006% FS', 'serial_number': '2187088', 'time_zone': 'Unknown'}, {'accuracy': '+-0.5°C from -20 to 70°C (-4° to 158°F).', 'calibration': 'Calibrated accordingly', 'instrument_manufacturer': 'HOBO', 'instrument_model': 'MX Water Temperature Data Logger w/Bluetooth', 'instrument_type': 'Data Logger', 'notes_method': 'N/A', 'parameter': 'Water Temperature', 'parameter_unit': 'degrees celsius', 'range': '-20° to 50°C (-4° to 122°F) in water.', 'resolution': '0.04°C (0.072°F)', 'serial_number': '21686202', 'time_zone': 'Unknown'}, {'accuracy': '± 0.05% FS (Barologger 5: ± 0.05 kPa)', 'calibration': 'Calibrated Accordingly', 'instrument_manufacturer': 'Solinst', 'instrument_model': '3250 LevelVent 5 ', 'instrument_type': 'Data Logger', 'notes_method': 'N/A', 'parameter': 'water_level', 'parameter_unit': 'metres', 'range': '0º to 50ºC (Barologger 5: -10 to +50ºC)', 'resolution': '0.002% FS to 0.0006% FS', 'serial_number': '', 'time_zone': 'Unknown'}]
Position0
Recent qa date2024-11-12
Resource citationLiving Lakes Canada. (2023). Preliminary Hydrometric (2023-08-09 to 2024-09-12) Kelly Creek (LCKKEL01H) [Resource]. Columbia Basin Water Hub. DOI
Resource data disclaimerThe data presented herein is of a preliminary nature and should be treated as such. The preliminary nature of the data implies that it is subject to revision, verification, and validation. Users are advised to exercise caution and independently verify the accuracy and reliability of the data before making any decisions or drawing conclusions based on it. Living Lakes Canada is responsible for providing the preliminary data and disclaims any warranty or guarantee, express or implied, regarding its accuracy, completeness, or suitability for any particular purpose. Living Lakes Canada carries no liability and use of the preliminary data is solely at the user's own risk, and the organization shall not be held liable for any damages or losses resulting from its use. Your proceeding beyond this Disclaimer will constitute your acceptance of the terms and conditions outlined above
Resource locationMonitoring location is approximately 4km east of Fruitvale.
Site[{'datum': 'Not specified', 'elevation': 788, 'latitude': 49.10728, 'longitude': -117.51236, 'site_id': 'LCKKEL01H', 'site_name': 'Kelly Creek', 'waterbody': 'Kelly Creek', 'waterbody_type': 'stream/river'}]
Size25.3 MiB
Stateactive
Url typeupload
Waterhub gradeTechnical Research Grade
Citation (Required) Living Lakes Canada. (2023). Preliminary Hydrometric (2023-08-09 to 2024-09-12) Kelly Creek (LCKKEL01H) [Resource]. Columbia Basin Water Hub. DOI
Resource Location Monitoring location is approximately 4km east of Fruitvale.
Data Collection Information A pressure logger is deployed at the hydrometric station. Measurements are recorded at 5 minute intervals.
Data Processing Data review, outlier trimming, stage-discharge relationship evaluation, internal computations to convert pressure measurements to stream discharge.
Data Disclaimer The data presented herein is of a preliminary nature and should be treated as such. The preliminary nature of the data implies that it is subject to revision, verification, and validation. Users are advised to exercise caution and independently verify the accuracy and reliability of the data before making any decisions or drawing conclusions based on it. Living Lakes Canada is responsible for providing the preliminary data and disclaims any warranty or guarantee, express or implied, regarding its accuracy, completeness, or suitability for any particular purpose. Living Lakes Canada carries no liability and use of the preliminary data is solely at the user's own risk, and the organization shall not be held liable for any damages or losses resulting from its use. Your proceeding beyond this Disclaimer will constitute your acceptance of the terms and conditions outlined above
Water Hub Data Grade Technical Research Grade
Date of Most Recent Water Hub QA/QC 2024-11-12
Loading Status Table was successfully loaded: 233212 rows
Datastore Status pending
Data type General

Data Dictionary

Column Type Label Description BODC ID
date_time text
site_id text
latitude float8
longitude float8
notes float8
discharge float8
discharge_units text
water_level float8
water_level_units text
water_temperature float8
water_temperature_units text
water_hub_qa_qc text

Site

LCKKEL01H
Field Value
Site ID LCKKEL01H
Site Name Kelly Creek
Waterbody Type Stream/River
Waterbody Kelly Creek
Site Latitude 49.10728
Site Longitude -117.51236
Location Coordinate System Not specified
Site Elevation (masl) 788

Parameter

Discharge
Field Value
Parameter Discharge
Time Zone Unknown
Unit of Measurement metres3 per second
Instrument Type Data Logger
Instrument Manufacturer Solinst
Instrument Model 3250 LevelVent 5
Serial Number 2187088
Instrument Accuracy ± 0.05% FS (Barologger 5: ± 0.05 kPa)
Range 0º to 50ºC (Barologger 5: -10 to +50ºC)
Resolution 0.002% FS to 0.0006% FS
Calibration Notes Calibrated accordingly
Notes on Method N/A
Water Temperature
Field Value
Parameter Water Temperature
Time Zone Unknown
Unit of Measurement degrees Celsius
Instrument Type Data Logger
Instrument Manufacturer HOBO
Instrument Model MX Water Temperature Data Logger w/Bluetooth
Serial Number 21686202
Instrument Accuracy +-0.5°C from -20 to 70°C (-4° to 158°F).
Range -20° to 50°C (-4° to 122°F) in water.
Resolution 0.04°C (0.072°F)
Calibration Notes Calibrated accordingly
Notes on Method N/A
water_level
Field Value
Parameter water_level
Time Zone Unknown
Unit of Measurement metres
Instrument Type Data Logger
Instrument Manufacturer Solinst
Instrument Model 3250 LevelVent 5
Serial Number
Instrument Accuracy ± 0.05% FS (Barologger 5: ± 0.05 kPa)
Range 0º to 50ºC (Barologger 5: -10 to +50ºC)
Resolution 0.002% FS to 0.0006% FS
Calibration Notes Calibrated Accordingly
Notes on Method N/A