Resource metadata

Field Value
Data last updated March 14, 2024
Metadata last updated March 14, 2024
Created September 13, 2021
Format CSV
License CC-BY-SA-4.0
Ckan urlhttps://data.cbwaterhub.ca
Data collection infoTemperature and pH are measured using a Hanna Industries pen meter (HI98129) within 2-4” of the surface. Secchi depths are collected where there is sufficient depth to measure from the sampling location. Data collection is consistent with the Invasive Mussel Field Protocol prepared by the Ecosystems Branch, BC Ministry of Environment and Climate Change Strategy.
Data processingThe Water Hub has performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data typenon-lab
Datastore activeTrue
Datastore contains all records of source fileTrue
Datastore statuspending
Has viewsTrue
Hashb466d119db5b39da370b7dc3d07e2153
Header row1
Ida53e2cd4-efbb-4867-975b-982e4175c754
Ignore hashTrue
Load statusERROR: Unable to find a usable engine; tried using: 'sqlalchemy'. A suitable version of sqlalchemy is required for sql I/O support. Trying to import the above resulted in these errors: - Pandas requires version '1.4.16' or newer of 'sqlalchemy' (version '1.3.5' currently installed).
Mimetypetext/csv
Original urlhttps://data.cbwaterhub.ca/dataset/b62f0345-867a-4fe4-815b-03cc5d8ccd1c/resource/a53e2cd4-efbb-4867-975b-982e4175c754/download/csiss_waterquality_revelstokelakemarthacreek_20170627_20230920.csv
Package idb62f0345-867a-4fe4-815b-03cc5d8ccd1c
Parameter[{'accuracy': '±0.5°C', 'calibration': 'N/A', 'instrument_manufacturer': 'HANNA Instruments', 'instrument_model': 'HI98129', 'instrument_type': 'Portable Multiparameter Meter', 'notes_method': 'Low range combination meter', 'parameter': 'Water Temperature', 'parameter_unit': 'degrees celsius', 'range': '-5.0 to 60.0°C', 'resolution': '0.1°C', 'time_zone': 'MT'}, {'accuracy': '±0.05 pH', 'calibration': 'pH is calibrated weekly', 'instrument_manufacturer': 'HANNA Instruments', 'instrument_model': 'HI98129', 'instrument_type': 'Portable Multiparameter Meter', 'notes_method': 'Low range combination meter', 'parameter': 'pH', 'parameter_unit': 'ph units', 'range': '0.00 to 14.00 pH', 'resolution': '0.01 pH', 'time_zone': 'MT'}, {'accuracy': 'N/A', 'calibration': 'N/A', 'instrument_manufacturer': 'N/A', 'instrument_model': 'N/A', 'instrument_type': 'Secchi Disk', 'notes_method': 'Methodology consistent with Invasive Mussel Field Protocol prepared by the Ecosystems Branch, BC Ministry of Environment and Climate Change Strategy', 'parameter': 'depth', 'parameter_unit': 'metres', 'range': 'N/A', 'resolution': 'N/A', 'time_zone': 'N/A'}]
Position0
Recent qa date2024-03-14
Resource citationColumbia Shuswap Invasive Species Society. (2023). Water Quality (2017-06-27 to 2023-09-023) Lake Revelstoke at Martha Creek. [Resource]. Columbia Basin Water Hub . https://doi.org/10.48511/VJF8-E337
Resource data disclaimerNo warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. Instrument accuracy may be limited. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Resource ida53e2cd4-efbb-4867-975b-982e4175c754
Resource locationLake Revelstoke at Martha Creek, shallow dock near boat launch in enclosed inlet
Set url typeFalse
Site[{'datum': 'WGS84', 'elevation': 575, 'latitude': 51.147299, 'longitude': -118.200065, 'site_id': 'revelstoke_martha', 'site_name': 'Martha Creek', 'waterbody': 'Martha Creek', 'waterbody_type': 'lake'}]
Size4.9 KiB
Stateactive
Task created2024-03-14 18:20:14.801212
Url typeupload
Waterhub gradeCommunity Research Grade
Citation (Required) Columbia Shuswap Invasive Species Society. (2023). Water Quality (2017-06-27 to 2023-09-023) Lake Revelstoke at Martha Creek. [Resource]. Columbia Basin Water Hub . https://doi.org/10.48511/VJF8-E337
Resource Location Lake Revelstoke at Martha Creek, shallow dock near boat launch in enclosed inlet
Data Collection Information Temperature and pH are measured using a Hanna Industries pen meter (HI98129) within 2-4” of the surface. Secchi depths are collected where there is sufficient depth to measure from the sampling location. Data collection is consistent with the Invasive Mussel Field Protocol prepared by the Ecosystems Branch, BC Ministry of Environment and Climate Change Strategy.
Data Processing The Water Hub has performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data Disclaimer No warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. Instrument accuracy may be limited. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Water Hub Data Grade Community Research Grade
Date of Most Recent Water Hub QA/QC 2024-03-14
Loading Status ERROR: Unable to find a usable engine; tried using: 'sqlalchemy'. A suitable version of sqlalchemy is required for sql I/O support. Trying to import the above resulted in these errors: - Pandas requires version '1.4.16' or newer of 'sqlalchemy' (version '1.3.5' currently installed).
Datastore Status pending
Data type General

Data Dictionary

Column Type Label Description BODC ID
date_time text
site_id text
latitude text
longitude text
notes text
water_temperature text
water_temperature_units text
pH text PHXXPR01 pH per unit volume of the water body by pH electrode SDN:P01::PHXXPR01
pH_units text
depth text Depth The length of wire between the ship and an object being lowered from a winch, which is assumed or wire-angle corrected to be the vertical distance between the ship and the object. SDN:P01::DEPHWO01
depth_units text
water_hub_qa_qc text

Site

revelstoke_martha
Field Value
Site ID revelstoke_martha
Site Name Martha Creek
Waterbody Type Lake
Waterbody Martha Creek
Site Latitude 51.147299
Site Longitude -118.200065
Location Coordinate System WGS84
Site Elevation (masl) 575

Parameter

Water Temperature
Field Value
Parameter Water Temperature
Time Zone MT
Unit of Measurement degrees Celsius
Instrument Type Portable Multiparameter Meter
Instrument Manufacturer HANNA Instruments
Instrument Model HI98129
Instrument Accuracy ±0.5°C
Range -5.0 to 60.0°C
Resolution 0.1°C
Calibration Notes N/A
Notes on Method Low range combination meter
pH
Field Value
Parameter pH
Time Zone MT
Unit of Measurement pH units
Instrument Type Portable Multiparameter Meter
Instrument Manufacturer HANNA Instruments
Instrument Model HI98129
Instrument Accuracy ±0.05 pH
Range 0.00 to 14.00 pH
Resolution 0.01 pH
Calibration Notes pH is calibrated weekly
Notes on Method Low range combination meter
depth
Field Value
Parameter depth
Time Zone N/A
Unit of Measurement metres
Instrument Type Secchi Disk
Instrument Manufacturer N/A
Instrument Model N/A
Instrument Accuracy N/A
Range N/A
Resolution N/A
Calibration Notes N/A
Notes on Method Methodology consistent with Invasive Mussel Field Protocol prepared by the Ecosystems Branch, BC Ministry of Environment and Climate Change Strategy