Resource metadata

Field Value
Data last updated November 12, 2024
Metadata last updated November 18, 2024
Created August 27, 2024
Format CSV
License CC-BY-SA-4.0
Data collection infoA pressure logger is deployed at the hydrometric station. Measurements are recorded at 5 minute intervals.
Data processingData review, outlier trimming, stage-discharge relationship evaluation, internal computations to convert pressure measurements to stream discharge.
Data typenon-lab
Datastore activeTrue
Datastore contains all records of source fileFalse
Datastore statuspending
Has viewsTrue
Hash478bdf03bcab2f0745f30d0a32075ff1
Header row1
Idb2c6bf15-4e09-487e-96e9-883a210fc0af
Load statusTable was successfully loaded: 217144 rows
Mimetypetext/csv
Package id8f9e4152-b9e5-4df3-9045-f94260279a48
Parameter[{'accuracy': '0.05% FS', 'calibration': 'Calibration certificate available', 'instrument_manufacturer': 'Solinst', 'instrument_model': '3250 LevelVent', 'instrument_type': 'Data Logger', 'notes_method': 'N/A', 'parameter': 'Water Temperature', 'parameter_unit': 'degrees celsius', 'range': '0ºC to 50ºC', 'resolution': 'Not Specified', 'serial_number': '2185397', 'time_zone': 'GMT-8'}, {'accuracy': '0.05% FS', 'calibration': 'Callibration certificate available.', 'instrument_manufacturer': 'Solinst', 'instrument_model': '3250 LevelVent5', 'instrument_type': 'Data Logger', 'notes_method': 'N/A', 'parameter': 'Discharge', 'parameter_unit': 'metres3 per second', 'range': '0ºC to 50ºC', 'resolution': 'Not Specified', 'serial_number': '2185397', 'time_zone': 'GMT-8'}, {'accuracy': '0.05% FS', 'calibration': 'Calibration certificate available', 'instrument_manufacturer': 'Solinst', 'instrument_model': '3250 LevelVent5', 'instrument_type': 'Data Logger', 'notes_method': 'N/A', 'parameter': 'water_level', 'parameter_unit': 'metres above sea level', 'range': '0ºC to 50ºC', 'resolution': 'Not Specified', 'serial_number': '2185397', 'time_zone': 'GMT-8'}]
Position0
Recent qa date2024-11-18
Resource citationLiving Lakes Canada. (2024). Preliminary Discharge and Temperature (2023-10-07 to 2024-09-27) Lower Apex Creek [Resource]. Columbia Basin Water Hub.
Resource data disclaimerThe data presented herein is of a preliminary nature and should be treated as such. The preliminary nature of the data implies that it is subject to revision, verification, and validation. Users are advised to exercise caution and independently verify the accuracy and reliability of the data before making any decisions or drawing conclusions based on it. Living Lakes Canada is responsible for providing the preliminary data and disclaims any warranty or guarantee, express or implied, regarding its accuracy, completeness, or suitability for any particular purpose. Living Lakes Canada carries no liability and use of the preliminary data is solely at the user's own risk, and the organization shall not be held liable for any damages or losses resulting from its use. Your proceeding beyond this Disclaimer will constitute your acceptance of the terms and conditions outlined above.
Resource location13 km South of Nelson, BC
Site[{'datum': 'Not specified', 'elevation': 1007, 'latitude': 49.40611, 'longitude': -117.19989, 'site_id': 'LCKAPX01H', 'site_name': 'Lower Apex Creek Hydrometric', 'waterbody': 'Apex Creek', 'waterbody_type': 'stream/river'}]
Size25.9 MiB
Stateactive
Url typeupload
Waterhub gradeTechnical Research Grade
Citation (Required) Living Lakes Canada. (2024). Preliminary Discharge and Temperature (2023-10-07 to 2024-09-27) Lower Apex Creek [Resource]. Columbia Basin Water Hub.
Resource Location 13 km South of Nelson, BC
Data Collection Information A pressure logger is deployed at the hydrometric station. Measurements are recorded at 5 minute intervals.
Data Processing Data review, outlier trimming, stage-discharge relationship evaluation, internal computations to convert pressure measurements to stream discharge.
Data Disclaimer The data presented herein is of a preliminary nature and should be treated as such. The preliminary nature of the data implies that it is subject to revision, verification, and validation. Users are advised to exercise caution and independently verify the accuracy and reliability of the data before making any decisions or drawing conclusions based on it. Living Lakes Canada is responsible for providing the preliminary data and disclaims any warranty or guarantee, express or implied, regarding its accuracy, completeness, or suitability for any particular purpose. Living Lakes Canada carries no liability and use of the preliminary data is solely at the user's own risk, and the organization shall not be held liable for any damages or losses resulting from its use. Your proceeding beyond this Disclaimer will constitute your acceptance of the terms and conditions outlined above.
Water Hub Data Grade Technical Research Grade
Date of Most Recent Water Hub QA/QC 2024-11-18
Loading Status Table was successfully loaded: 217144 rows
Datastore Status pending
Data type General

Data Dictionary

Column Type Label Description BODC ID
date_time text
site_id text
latitude text
longitude text
notes text
discharge text
discharge_units text
water_level text DepBelowSurf The distance of a sensor or sampling point below the sea surface SDN:P01::ADEPZZ01
water_level_units text
water_temperature text
water_temperature_units text
water_hub_qa_qc text

Site

LCKAPX01H
Field Value
Site ID LCKAPX01H
Site Name Lower Apex Creek Hydrometric
Waterbody Type Stream/River
Waterbody Apex Creek
Site Latitude 49.40611
Site Longitude -117.19989
Location Coordinate System Not specified
Site Elevation (masl) 1007

Parameter

Water Temperature
Field Value
Parameter Water Temperature
Time Zone GMT-8
Unit of Measurement degrees Celsius
Instrument Type Data Logger
Instrument Manufacturer Solinst
Instrument Model 3250 LevelVent
Serial Number 2185397
Instrument Accuracy 0.05% FS
Range 0ºC to 50ºC
Resolution Not Specified
Calibration Notes Calibration certificate available
Notes on Method N/A
Discharge
Field Value
Parameter Discharge
Time Zone GMT-8
Unit of Measurement metres3 per second
Instrument Type Data Logger
Instrument Manufacturer Solinst
Instrument Model 3250 LevelVent5
Serial Number 2185397
Instrument Accuracy 0.05% FS
Range 0ºC to 50ºC
Resolution Not Specified
Calibration Notes Callibration certificate available.
Notes on Method N/A
water_level
Field Value
Parameter water_level
Time Zone GMT-8
Unit of Measurement metres above sea level
Instrument Type Data Logger
Instrument Manufacturer Solinst
Instrument Model 3250 LevelVent5
Serial Number 2185397
Instrument Accuracy 0.05% FS
Range 0ºC to 50ºC
Resolution Not Specified
Calibration Notes Calibration certificate available
Notes on Method N/A