Resource metadata

Field Value
Data last updated January 30, 2025
Metadata last updated January 30, 2025
Created January 30, 2025
Format CSV
License CC-BY-NC-SA-4.0
Data collection infoData is collected from hydrometric stations that measure water level (stage). For stream sites, this measured water level is used to calculate discharge (the volume of water flowing past at a particular time). Water temperature is also collected at these permanent hydrometric stations.
Data processingReal time water stage data is subject to preliminary correction to compensate for manual stage measurements, as well as potential instrument drift. Stage data that appears suspect or is impacted by ice within the winter is also removed. Data is finalized once a year, at which time corrections are confirmed and additional corrections (such as data filling and smoothing) may be applied.
Data typenon-lab
Datastore activeTrue
Datastore contains all records of source fileFalse
Datastore statusready
Has viewsTrue
Hashf162837b182ea544c8a73caf0dd32f16
Header row1
Idedab0f1a-4713-482e-a050-1e6a66d83d62
Load statusTable was successfully loaded: 18901 rows
Mimetypetext/csv
Package ide1bbb07c-5e14-4f01-89e3-0c97a7404e9e
Parameter[{'accuracy': '± 0.05ºC', 'calibration': 'Factory Calibrated', 'instrument_manufacturer': 'Solinst', 'instrument_model': 'Level Vent 5', 'instrument_type': 'Data Logger', 'notes_method': 'N/A', 'parameter': 'Water Temperature', 'parameter_unit': 'degrees celsius', 'range': '-20ºC to 80ºC', 'resolution': '0.003°C', 'serial_number': '', 'time_zone': 'Unknown'}, {'accuracy': '± 0.05% FS (Barologger 5: ± 0.05 kPa)', 'calibration': 'Calibrated Accordingly', 'instrument_manufacturer': 'Solinst', 'instrument_model': 'Level Vent 5', 'instrument_type': 'Data Logger', 'notes_method': 'N/A', 'parameter': 'water_level', 'parameter_unit': 'metres', 'range': '0º to 50ºC (Barologger 5: -10 to +50ºC)', 'resolution': '0.002% FS to 0.0006% FS', 'serial_number': '', 'time_zone': 'Unknown'}]
Position0
Recent qa date2025-01-30
Resource citationLiving Lakes Canada. (2024). Preliminary Water Level (2024-03-27 to 2024-10-10) Lower Reserve Creek (UKKRSV01H) [Resource]. Columbia Basin Water Hub. DOI
Resource data disclaimerThe data presented herein is of a preliminary nature and should be treated as such. The preliminary nature of the data implies that it is subject to revision, verification, and validation. Users are advised to exercise caution and independently verify the accuracy and reliability of the data before making any decisions or drawing conclusions based on it. Living Lakes Canada is responsible for providing the preliminary data and disclaims any warranty or guarantee, express or implied, regarding its accuracy, completeness, or suitability for any particular purpose. Living Lakes Canada carries no liability and use of the preliminary data is solely at the user's own risk, and the organization shall not be held liable for any damages or losses resulting from its use. Your proceeding beyond this Disclaimer will constitute your acceptance of the terms and conditions outlined above.
Resource locationMonitoring station located 7km north of the United States border.
Site[{'datum': 'Not specified', 'elevation': 890, 'latitude': 49.092208, 'longitude': -115.074653, 'site_id': 'UKKRSV01H', 'site_name': 'Lower Reserve Creek Hydrometric', 'waterbody': 'Lower Reserve Creek', 'waterbody_type': 'stream/river'}]
Size1.8 MiB
Stateactive
Url typeupload
Waterhub gradeTechnical Research Grade
Citation (Required) Living Lakes Canada. (2024). Preliminary Water Level (2024-03-27 to 2024-10-10) Lower Reserve Creek (UKKRSV01H) [Resource]. Columbia Basin Water Hub. DOI
Resource Location Monitoring station located 7km north of the United States border.
Data Collection Information Data is collected from hydrometric stations that measure water level (stage). For stream sites, this measured water level is used to calculate discharge (the volume of water flowing past at a particular time). Water temperature is also collected at these permanent hydrometric stations.
Data Processing Real time water stage data is subject to preliminary correction to compensate for manual stage measurements, as well as potential instrument drift. Stage data that appears suspect or is impacted by ice within the winter is also removed. Data is finalized once a year, at which time corrections are confirmed and additional corrections (such as data filling and smoothing) may be applied.
Data Disclaimer The data presented herein is of a preliminary nature and should be treated as such. The preliminary nature of the data implies that it is subject to revision, verification, and validation. Users are advised to exercise caution and independently verify the accuracy and reliability of the data before making any decisions or drawing conclusions based on it. Living Lakes Canada is responsible for providing the preliminary data and disclaims any warranty or guarantee, express or implied, regarding its accuracy, completeness, or suitability for any particular purpose. Living Lakes Canada carries no liability and use of the preliminary data is solely at the user's own risk, and the organization shall not be held liable for any damages or losses resulting from its use. Your proceeding beyond this Disclaimer will constitute your acceptance of the terms and conditions outlined above.
Water Hub Data Grade Technical Research Grade
Date of Most Recent Water Hub QA/QC 2025-01-30
Loading Status Table was successfully loaded: 18901 rows
Datastore Status ready
Data type General

Data Dictionary

Column Type Label Description BODC ID
date_time text
site_id text
latitude float8
longitude float8
notes float8
water_level float8
water_level_units text
water_temperature float8
water_temperature_units text
water_hub_qa_qc text

Site

UKKRSV01H
Field Value
Site ID UKKRSV01H
Site Name Lower Reserve Creek Hydrometric
Waterbody Type Stream/River
Waterbody Lower Reserve Creek
Site Latitude 49.092208
Site Longitude -115.074653
Location Coordinate System Not specified
Site Elevation (masl) 890

Parameter

Water Temperature
Field Value
Parameter Water Temperature
Time Zone Unknown
Unit of Measurement degrees Celsius
Instrument Type Data Logger
Instrument Manufacturer Solinst
Instrument Model Level Vent 5
Serial Number
Instrument Accuracy ± 0.05ºC
Range -20ºC to 80ºC
Resolution 0.003°C
Calibration Notes Factory Calibrated
Notes on Method N/A
water_level
Field Value
Parameter water_level
Time Zone Unknown
Unit of Measurement metres
Instrument Type Data Logger
Instrument Manufacturer Solinst
Instrument Model Level Vent 5
Serial Number
Instrument Accuracy ± 0.05% FS (Barologger 5: ± 0.05 kPa)
Range 0º to 50ºC (Barologger 5: -10 to +50ºC)
Resolution 0.002% FS to 0.0006% FS
Calibration Notes Calibrated Accordingly
Notes on Method N/A