Resource metadata

Field Value
Data last updated December 6, 2023
Metadata last updated July 18, 2024
Created March 29, 2022
Format CSV
License CC-BY-SA-4.0
Data collection infoThe temperature loggers were deployed at the same locations for several years. They were installed fastened to a cable that was wrapped around a boulder or tree adjacent to the river.
Data processingParameters with unacceptably high or low readings were removed. These readings were likely due to the logger being swept out of the water during freshet or major weather events. The Water Hub has performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data typenon-lab
Datastore activeTrue
Datastore contains all records of source fileFalse
Datastore statusready
Has viewsTrue
Hashd7a946b67fc11cc6bc7305be45a6abbe
Header row1
Ida3507ee6-72a0-4b74-80cf-14048bcafcf7
Load statusTable was successfully loaded: 127450 rows
Mimetypetext/csv
Package idbd652a21-28a6-4f3b-af7e-711e8fd72055
Parameter[{'accuracy': '±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F)', 'calibration': 'Calibration is completed at each readout event. The logger is removed from metal housing tube and connected to HOBO Shuttel where the data is transfered. The shuttle is then offloaded onto the computer for analysis. The is compleated roughly once each year. During read out the loggers are checked for any damage to the logger/housing and battery status. Loggers with low betterie life and/or damage are replaced.', 'instrument_manufacturer': 'HOBO', 'instrument_model': 'Pro V2', 'instrument_type': 'Data Logger', 'notes_method': 'Temperature Loggers are housed in a metal tube that is attached to a cable fastened to a tree or rock on shore. Cable lenghts range from 2 to 4 meters. The logger/housing is placed in a deep pool and pinched between rocks to secure them during freshet. ', 'parameter': 'Water Temperature', 'parameter_unit': 'degrees celsius', 'range': '-40° to 70°C (-40° to 158°F) in air; maximum sustained temperature of 50°C (122°F) in water', 'resolution': '0.02°C at 25°C (0.04°F at 77°F)', 'serial_number': 'N/A', 'time_zone': 'PST'}]
Position2
Resource citationSalmo Watershed Streamkeepers Society. (2021). Temperature (2003-08-29 to 2021-05-31) Sheep Creek (Upper - NESHP03 and Lower - NESHP01). Columbia Basin Water Hub [Resource]. Salmo. https://doi.org/10.48511/BDVW-0M90
Resource data disclaimerNo warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Resource locationSheep Creek Lower is ~50m downstream of Curtis Creek FSR bridge on river right at leaning tall stump just before log waterfall (NESHP03). Sheep Creek Lower is located ~10m upstream from discharge site downstream of bridge on Airport Rd. River Right (NESHP01).
Site[{'datum': 'WGS84', 'elevation': 1190, 'latitude': 49.159716, 'longitude': -117.092431, 'site_id': 'Sheep_upper', 'site_name': 'Sheep_upper', 'waterbody': 'Salmo River', 'waterbody_type': 'stream/river'}, {'datum': 'WGS84', 'elevation': 642, 'latitude': 49.140878, 'longitude': -117.258953, 'site_id': 'Sheep_lower', 'site_name': 'Sheep_lower', 'waterbody': 'Salmo River', 'waterbody_type': 'stream/river'}]
Size12 MiB
Stateactive
Url typeupload
Waterhub gradeCommunity Research Grade
Citation (Required) Salmo Watershed Streamkeepers Society. (2021). Temperature (2003-08-29 to 2021-05-31) Sheep Creek (Upper - NESHP03 and Lower - NESHP01). Columbia Basin Water Hub [Resource]. Salmo. https://doi.org/10.48511/BDVW-0M90
Resource Location Sheep Creek Lower is ~50m downstream of Curtis Creek FSR bridge on river right at leaning tall stump just before log waterfall (NESHP03). Sheep Creek Lower is located ~10m upstream from discharge site downstream of bridge on Airport Rd. River Right (NESHP01).
Data Collection Information The temperature loggers were deployed at the same locations for several years. They were installed fastened to a cable that was wrapped around a boulder or tree adjacent to the river.
Data Processing Parameters with unacceptably high or low readings were removed. These readings were likely due to the logger being swept out of the water during freshet or major weather events. The Water Hub has performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose.
Data Disclaimer No warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Water Hub Data Grade Community Research Grade
Date of Most Recent Water Hub QA/QC
Loading Status Table was successfully loaded: 127450 rows
Datastore Status ready
Data type General

Data Dictionary

Column Type Label Description BODC ID
date_time timestamp
site_id text
latitude float8
longitude text
notes float8
water_temperature float8
water_temperature_units text
water_hub_qa_qc float8

Site

Sheep_upper
Field Value
Site ID Sheep_upper
Site Name Sheep_upper
Waterbody Type Stream/River
Waterbody Salmo River
Site Latitude 49.159716
Site Longitude -117.092431
Location Coordinate System WGS84
Site Elevation (masl) 1190
Sheep_lower
Field Value
Site ID Sheep_lower
Site Name Sheep_lower
Waterbody Type Stream/River
Waterbody Salmo River
Site Latitude 49.140878
Site Longitude -117.258953
Location Coordinate System WGS84
Site Elevation (masl) 642

Parameter

Water Temperature
Field Value
Parameter Water Temperature
Time Zone PST
Unit of Measurement degrees Celsius
Instrument Type Data Logger
Instrument Manufacturer HOBO
Instrument Model Pro V2
Serial Number N/A
Instrument Accuracy ±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F)
Range -40° to 70°C (-40° to 158°F) in air; maximum sustained temperature of 50°C (122°F) in water
Resolution 0.02°C at 25°C (0.04°F at 77°F)
Calibration Notes Calibration is completed at each readout event. The logger is removed from metal housing tube and connected to HOBO Shuttel where the data is transfered. The shuttle is then offloaded onto the computer for analysis. The is compleated roughly once each year. During read out the loggers are checked for any damage to the logger/housing and battery status. Loggers with low betterie life and/or damage are replaced.
Notes on Method Temperature Loggers are housed in a metal tube that is attached to a cable fastened to a tree or rock on shore. Cable lenghts range from 2 to 4 meters. The logger/housing is placed in a deep pool and pinched between rocks to secure them during freshet.