Skip to content

Changes

View changes from to


On February 16, 2024 at 12:56:11 AM UTC, Gravatar maggiefa:
  • Changed value of field resource_citation of resource Preliminary Hydrometric (2022-09-03 to 2023-06-26) Upper Wilson Creek to Living Lakes Canada. (2023). Preliminary Hydrometric (2022-09-03 to 2023-06-26) Upper Wilson Creek [Resource]. Columbia Basin Water Hub. https://doi.org/10.48511/kvf4-bv12 (previously Living Lakes Canada. (2023). Preliminary Hydrometric (2022-09-03 to 2023-06-26) Upper Wilson Creek [Resource]. Columbia Basin Water Hub. DOI) in Upper Wilson Creek Hydrometric (MCKWIL01H)


  • Changed value of field resource_location of resource Preliminary Hydrometric (2022-09-03 to 2023-06-26) Upper Wilson Creek to Monitoring station is located approximately 8.3km East of Hills in upper reaches of Wilson Creek (previously 8km east of Hills) in Upper Wilson Creek Hydrometric (MCKWIL01H)


  • Changed value of field resource_data_disclaimer of resource Preliminary Hydrometric (2022-09-03 to 2023-06-26) Upper Wilson Creek to The data presented herein is of a preliminary nature and should be treated as such. The preliminary nature of the data implies that it is subject to revision, verification, and validation. Users are advised to exercise caution and independently verify the accuracy and reliability of the data before making any decisions or drawing conclusions based on it. Living Lakes Canada is responsible for providing the preliminary data and disclaims any warranty or guarantee, express or implied, regarding its accuracy, completeness, or suitability for any particular purpose. Living Lakes Canada carries no liability and use of the preliminary data is solely at the user's own risk, and the organization shall not be held liable for any damages or losses resulting from its use. Your proceeding beyond this Disclaimer will constitute your acceptance of the terms and conditions outlined above. (previously The data presented herein is of a preliminary nature and should be treated as such. The preliminary nature of the data implies that it is subject to revision, verification, and validation. Users are advised to exercise caution and independently verify the accuracy and reliability of the data before making any decisions or drawing conclusions based on it. Living Lakes Canada is responsible for providing the preliminary data and disclaims any warranty or guarantee, express or implied, regarding its accuracy, completeness, or suitability for any particular purpose. Living Lakes Canada carries no liability and use of the preliminary data is solely at the user's own risk, and the organization shall not be held liable for any damages or losses resulting from its use. Your proceeding beyond this Disclaimer will constitute your acceptance of the terms and conditions outlined above.) in Upper Wilson Creek Hydrometric (MCKWIL01H)


  • Changed value of field parameter of resource Preliminary Hydrometric (2022-09-03 to 2023-06-26) Upper Wilson Creek to [{'accuracy': '± 0.05ºC', 'calibration': 'As per instructed', 'instrument_manufacturer': 'Solinist', 'instrument_model': 'LevelLogger', 'instrument_type': 'Data Logger', 'notes_method': 'Corrected', 'parameter': 'Water Temperature', 'parameter_unit': 'degrees celsius', 'range': "'-20ºC to 80ºC", 'resolution': '0.003°C', 'serial_number': 214530, 'time_zone': 'PT'}, {'accuracy': '± 0.05% FS (Barologger 5: ± 0.05 kPa)', 'calibration': 'As per instructed', 'instrument_manufacturer': 'Solinist', 'instrument_model': 'LevelLogger', 'instrument_type': 'Data Logger', 'notes_method': 'N/A', 'parameter': 'water_level', 'parameter_unit': 'metres', 'range': '0º to 50ºC (Barologger 5: -10 to +50ºC)', 'resolution': '0.002% FS to 0.0006% FS', 'serial_number': 214530, 'time_zone': 'PT'}, {'accuracy': '± 0.05% FS (Barologger 5: ± 0.05 kPa)', 'calibration': 'As per instructed', 'instrument_manufacturer': 'Solinist', 'instrument_model': 'LevelLogger', 'instrument_type': 'Data Logger', 'notes_method': 'N/A', 'parameter': 'Discharge', 'parameter_unit': 'metres3 per second', 'range': '0º to 50ºC (Barologger 5: -10 to +50ºC)', 'resolution': '0.002% FS to 0.0006% FS', 'serial_number': 214530, 'time_zone': 'PT'}] (previously [{'accuracy': '± 0.05ºC', 'calibration': 'As per instructed', 'instrument_manufacturer': 'Solinist', 'instrument_model': 'LevelLogger', 'instrument_type': 'Data Logger', 'notes_method': 'Corrected', 'parameter': 'Water Temperature', 'parameter_unit': 'degrees celsius', 'range': "'-20ºC to 80ºC", 'resolution': '0.003°C', 'serial_number': '214530', 'time_zone': 'PT'}, {'accuracy': '± 0.05% FS (Barologger 5: ± 0.05 kPa)', 'calibration': 'As per instructed', 'instrument_manufacturer': 'Solinist', 'instrument_model': 'LevelLogger', 'instrument_type': 'Data Logger', 'notes_method': 'N/A', 'parameter': 'water_level', 'parameter_unit': 'metres', 'range': '0º to 50ºC (Barologger 5: -10 to +50ºC)', 'resolution': '0.002% FS to 0.0006% FS', 'serial_number': '214530', 'time_zone': 'PT'}, {'accuracy': '± 0.05% FS (Barologger 5: ± 0.05 kPa)', 'calibration': 'As per instructed', 'instrument_manufacturer': 'Solinist', 'instrument_model': 'LevelLogger', 'instrument_type': 'Data Logger', 'notes_method': 'N/A', 'parameter': 'Discharge', 'parameter_unit': 'metres3 per second', 'range': '0º to 50ºC (Barologger 5: -10 to +50ºC)', 'resolution': '0.002% FS to 0.0006% FS', 'serial_number': '214530', 'time_zone': 'PT'}]) in Upper Wilson Creek Hydrometric (MCKWIL01H)