Resource metadata

Field Value
Data last updated December 6, 2023
Metadata last updated December 11, 2023
Created January 14, 2022
Format CSV
License CC-BY-NC-SA-4.0
Data collection infoCKISS follows the British Columbia Dreissenid Mussel Lake Monitoring Field Protocol which is provided by the BC Ministry of Environment and Climate Change Strategy.
Data processingData validation to check if values within expected ranges, outliers flagged. The Water Hub has performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose. The Water Hub is not conducting QA/QC on the lab values themselves.
Data typenon-lab
Datastore activeTrue
Datastore contains all records of source fileFalse
Datastore statusready
Has viewsTrue
Hash7bece5c8c676ae66f69a0d4d99468d43
Header row1
Id0a264098-159c-414e-8024-0afc9f97ee77
Load statusTable was successfully loaded: 20 rows
Mimetypetext/csv
Package id9a7b1605-00bc-45cd-b6d4-7766c440ccc4
Parameter[{'accuracy': '0.5', 'calibration': 'N/A', 'instrument_manufacturer': 'N/A', 'instrument_model': 'N/A', 'instrument_type': 'Analog Thermometer', 'notes_method': 'As per British Columbia Dreissenid Mussel Lake\r\nMonitoring Field Protocol\r\n', 'parameter': 'Water Temperature', 'parameter_unit': 'degrees celsius', 'resolution': 'N/A', 'serial_number': 1, 'time_zone': 'PT'}, {'accuracy': '0.2', 'calibration': 'Calibrated weekly as per manufacturer specification', 'instrument_manufacturer': 'Hanna Instruments', 'instrument_model': 'Checker 1 pH meter', 'instrument_type': 'Other', 'instrument_type_other': 'pH meter', 'notes_method': 'As per British Columbia Dreissenid Mussel Lake\r\nMonitoring Field Protocol\r\n', 'parameter': 'pH', 'parameter_unit': 'ph units', 'resolution': '0.1', 'serial_number': 1, 'time_zone': 'PT'}, {'accuracy': 'N/A', 'calibration': 'N/A', 'instrument_manufacturer': 'LaMotte', 'instrument_model': 'LaMotte secchi disc', 'instrument_type': 'Secchi Disk', 'notes_method': 'As per British Columbia Dreissenid Mussel Lake Monitoring Field Protocol\r\n', 'parameter': 'water_clarity_secchi', 'parameter_unit': 'metres', 'resolution': 'N/A', 'serial_number': 1, 'time_zone': 'N/A'}, {'accuracy': 'N/A', 'calibration': 'N/A', 'instrument_manufacturer': 'LaMotte', 'instrument_model': 'LaMotte secchi disc', 'instrument_type': 'Secchi Disk', 'notes_method': 'Trophic status is determined by Secchi Depth as per British Columbia Dreissenid Mussel Lake\r\nMonitoring Field Protocol\r\n', 'parameter': 'trophic status', 'parameter_unit': 'n/a', 'resolution': 'N/A', 'serial_number': 1, 'time_zone': 'N/A'}, {'accuracy': '±10 mg/L ±5% of reading', 'calibration': 'Calibrated weekly as per manufacturer specification', 'instrument_manufacturer': 'Hanna Instruments', 'instrument_model': 'HI 96752', 'instrument_type': 'Other', 'instrument_type_other': 'Portable Photometer', 'notes_method': 'Total Calcium was measured only in 2018, as Dissolved Calcium is the parameter required to inform ZQM habitat suitability. \r\n', 'parameter': 'Calcium Total', 'parameter_unit': 'milligrams per litre', 'resolution': '1 mg/L (ppm)', 'serial_number': 1, 'time_zone': 'N/A'}]
Position0
Resource citationCentral Kootenay Invasive Species Society. (2022). Field Water Quality (2018-06-15 to 2018-10-15) Pend D'Oreille River [Resource]. Columbia Basin Water Hub. https://doi.org/10.48511/ST1E-TZ21
Resource data disclaimerNo warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Resource locationMeasurements were taken at the Buckley Campground boat launch and at the Salmo River put-in. See metadata in download for site coordinates.
Site[{'datum': 'WGS84', 'elevation': 1, 'latitude': 49.039413, 'longitude': -117.492665, 'site_id': 'pdo_buckley', 'site_name': "Pend D'Oreille River at Buckley Campground boat launch", 'waterbody': "Pend D'Oreille River", 'waterbody_type': 'stream/river'}, {'datum': 'WGS84', 'elevation': 1, 'latitude': 49.024955, 'longitude': -117.38137, 'site_id': 'pdo_salmo', 'site_name': "Pend D'Oreille River at Salmo River put-in", 'waterbody': "Pend D'Oreille River", 'waterbody_type': 'stream/river'}]
Size4.1 KiB
Stateactive
Url typeupload
Waterhub gradeCommunity Research Grade
Citation (Required) Central Kootenay Invasive Species Society. (2022). Field Water Quality (2018-06-15 to 2018-10-15) Pend D'Oreille River [Resource]. Columbia Basin Water Hub. https://doi.org/10.48511/ST1E-TZ21
Resource Location Measurements were taken at the Buckley Campground boat launch and at the Salmo River put-in. See metadata in download for site coordinates.
Data Collection Information CKISS follows the British Columbia Dreissenid Mussel Lake Monitoring Field Protocol which is provided by the BC Ministry of Environment and Climate Change Strategy.
Data Processing Data validation to check if values within expected ranges, outliers flagged. The Water Hub has performed a preliminary QA/QC protocol on this data but the individual user must still confirm the accuracy of the data and whether it will be appropriate for their purpose. The Water Hub is not conducting QA/QC on the lab values themselves.
Data Disclaimer No warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose.
Water Hub Data Grade Community Research Grade
Date of Most Recent Water Hub QA/QC
Loading Status Table was successfully loaded: 20 rows
Datastore Status ready
Data type General

Data Dictionary

Column Type Label Description BODC ID
date_time timestamp
site_id text
latitude float8
longitude float8
notes text
water_temperature float8
water_temperature_units text
pH float8
pH_units text
water_clarity_secchi float8
water_clarity_secchi_units text
trophic_status text
trophic_status_units float8
calcium_total float8
calcium_total_units text
water_hub_qa_qc text

Site

pdo_buckley
Field Value
Site ID pdo_buckley
Site Name Pend D'Oreille River at Buckley Campground boat launch
Waterbody Type Stream/River
Waterbody Pend D'Oreille River
Site Latitude 49.039413
Site Longitude -117.492665
Location Coordinate System WGS84
Site Elevation (masl) 1
pdo_salmo
Field Value
Site ID pdo_salmo
Site Name Pend D'Oreille River at Salmo River put-in
Waterbody Type Stream/River
Waterbody Pend D'Oreille River
Site Latitude 49.024955
Site Longitude -117.38137
Location Coordinate System WGS84
Site Elevation (masl) 1

Parameter

Water Temperature
Field Value
Parameter Water Temperature
Time Zone PT
Unit of Measurement degrees Celsius
Instrument Type Analog Thermometer
Instrument Manufacturer N/A
Instrument Model N/A
Serial Number 1
Instrument Accuracy 0.5
Resolution N/A
Calibration Notes N/A
Notes on Method As per British Columbia Dreissenid Mussel Lake Monitoring Field Protocol
pH
Field Value
Parameter pH
Time Zone PT
Unit of Measurement pH units
Instrument Type Other
Other pH meter
Instrument Manufacturer Hanna Instruments
Instrument Model Checker 1 pH meter
Serial Number 1
Instrument Accuracy 0.2
Resolution 0.1
Calibration Notes Calibrated weekly as per manufacturer specification
Notes on Method As per British Columbia Dreissenid Mussel Lake Monitoring Field Protocol
water_clarity_secchi
Field Value
Parameter water_clarity_secchi
Time Zone N/A
Unit of Measurement metres
Instrument Type Secchi Disk
Instrument Manufacturer LaMotte
Instrument Model LaMotte secchi disc
Serial Number 1
Instrument Accuracy N/A
Resolution N/A
Calibration Notes N/A
Notes on Method As per British Columbia Dreissenid Mussel Lake Monitoring Field Protocol
trophic status
Field Value
Parameter trophic status
Time Zone N/A
Unit of Measurement N/A
Instrument Type Secchi Disk
Instrument Manufacturer LaMotte
Instrument Model LaMotte secchi disc
Serial Number 1
Instrument Accuracy N/A
Resolution N/A
Calibration Notes N/A
Notes on Method Trophic status is determined by Secchi Depth as per British Columbia Dreissenid Mussel Lake Monitoring Field Protocol
Calcium Total
Field Value
Parameter Calcium Total
Time Zone N/A
Unit of Measurement milligrams per litre
Instrument Type Other
Other Portable Photometer
Instrument Manufacturer Hanna Instruments
Instrument Model HI 96752
Serial Number 1
Instrument Accuracy ±10 mg/L ±5% of reading
Resolution 1 mg/L (ppm)
Calibration Notes Calibrated weekly as per manufacturer specification
Notes on Method Total Calcium was measured only in 2018, as Dissolved Calcium is the parameter required to inform ZQM habitat suitability.